This study presents a new dead-time measurement method using the gamma attenuation law and generalized dead-time models for nuclear gamma-ray detectors. The dead-time of the Nal(TI) detection system was obtained to validate the new dead-time determination method using very thin lead and polyethylene absorbers. Non-paralyzing dead-time was found to be 8.39 mu s, and paralyzing dead-time was found to be 8.35 mu s using lead absorber for Nal(TI) scintillator detection system. These dead-time values are consistent with the previously reported dead-time values for scintillator detection systems. The gamma build-up factor's contribution to the dead-time was neglected because a very thin material was used. (C) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:4093 / 4097
页数:5
相关论文
共 50 条
  • [21] A method to determine the gamma-ray linear attenuation coefficient
    Celiktas, C.
    ANNALS OF NUCLEAR ENERGY, 2011, 38 (09) : 2096 - 2100
  • [22] DETERMINATION OF EFFICIENCIES OF SEMICONDUCTOR GAMMA-RAY DETECTORS FOR INHOMOGENEOUS SAMPLES
    KORUN, M
    MARTINCIC, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2): : 148 - 155
  • [23] Determination of dead-time in photon counting photometers by a polarimetric method
    Clarke, D
    Deighan, G
    Fry, G
    Goodsir, S
    Macleod, D
    ASTROPHYSICS AND SPACE SCIENCE, 1996, 239 (02) : 229 - 235
  • [24] A PSEUDO-RANDOM PULSER TECHNIQUE FOR THE CORRECTION OF DEAD-TIME AND PILE-UP LOSSES IN GAMMA-RAY SPECTROMETRY
    DORFEL, G
    KLUGE, W
    KUBSCH, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3): : 435 - 440
  • [25] PRECISE SEDIMENT DENSITY DETERMINATION BY GAMMA-RAY ATTENUATION ALONE
    WHITMARSH, RB
    JOURNAL OF SEDIMENTARY PETROLOGY, 1971, 41 (03): : 882 - +
  • [26] SAMAR SHARED DEAD-TIME METHOD - NEW APPROACH TO BETA-GAMMA COINCIDENCE COUNTING
    DECARLOS, JE
    GRANADOS, CE
    NUCLEAR INSTRUMENTS & METHODS, 1973, 112 (1-2): : 209 - 212
  • [27] DIRECTIONAL-CORRELATION ATTENUATION FACTORS FOR GE(LI) GAMMA-RAY DETECTORS
    WINN, WG
    SARANTITES, DG
    NUCLEAR INSTRUMENTS & METHODS, 1968, 66 (01): : 61 - +
  • [28] A new method for determination of gamma-ray spectrometer non-linearity
    Fazekas, B
    Révay, Z
    Östör, J
    Belgya, T
    Molnár, G
    Simonits, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 469 - 473
  • [29] TIME-DEPENDENT POLARIZATION OF CDTE GAMMA-RAY DETECTORS
    BELL, RO
    ENTINE, G
    SERREZE, HB
    NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01): : 267 - 271
  • [30] A method for determination of gamma-ray direction in space
    Akkoyun, Serkan
    ACTA ASTRONAUTICA, 2013, 87 : 147 - 152