This study presents a new dead-time measurement method using the gamma attenuation law and generalized dead-time models for nuclear gamma-ray detectors. The dead-time of the Nal(TI) detection system was obtained to validate the new dead-time determination method using very thin lead and polyethylene absorbers. Non-paralyzing dead-time was found to be 8.39 mu s, and paralyzing dead-time was found to be 8.35 mu s using lead absorber for Nal(TI) scintillator detection system. These dead-time values are consistent with the previously reported dead-time values for scintillator detection systems. The gamma build-up factor's contribution to the dead-time was neglected because a very thin material was used. (C) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:4093 / 4097
页数:5
相关论文
共 50 条
  • [1] A Dead-Time Correction Method for Multiple Gamma-ray Detection
    Kimura, A.
    Furutaka, K.
    Goko, S.
    Harada, H.
    Igashira, M.
    Kamiyama, T.
    Katabuchi, T.
    Kin, T.
    Kino, K.
    Kitatani, F.
    Kiyanagi, Y.
    Koizumi, M.
    Mizumoto, M.
    Nakamura, S.
    Ohta, M.
    Oshima, M.
    Toh, Y.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 138 - +
  • [2] Measurement of the dead-time correction in gamma-ray spectrometry by the pulser method
    Korun, M
    Martincic, R
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1996, 14 (01): : 77 - 85
  • [3] SIMPLE DEAD-TIME STABILIZER FOR GAMMA-RAY SPECTROMETERS
    DEBRUIN, M
    THEN, SS
    BODE, P
    KORTHOVEN, PJ
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (03): : 611 - 613
  • [4] COUNTING LOSSES IN GAMMA-RAY SPECTROMETRY NOT ELIMINATED BY DEAD-TIME CORRECTION CIRCUITRY
    OLSON, DG
    HEALTH PHYSICS, 1986, 51 (03): : 380 - 381
  • [5] COUNTING LOSSES IN GAMMA-RAY SPECTROMETRY NOT ELIMINATED BY DEAD-TIME CORRECTION CIRCUITRY - COMMENT
    LAVERA, R
    HEALTH PHYSICS, 1987, 53 (02): : 198 - 198
  • [6] DEAD-TIME CORRECTION SYSTEM FOR GAMMA-RAY SPECTROMETRY OF SHORT-LIVED ISOTOPES
    BARTOSEK, J
    ADAMS, F
    HOSTE, J
    NUCLEAR INSTRUMENTS & METHODS, 1972, 103 (01): : 45 - &
  • [7] Dead-time in X-ray Photon Counting Detectors
    Laundy, David
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C39 - C39
  • [8] CORRECTION FOR DEAD-TIME LOSSES IN GAMMA-RAY SPECTROMETRY FOR A MIXTURE OF SHORT-LIVED RADIONUCLIDES
    WOITTIEZ, JRW
    ZONDERHUIS, J
    FAANHOF, A
    DAS, HA
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1979, 53 (1-2): : 191 - 201
  • [9] AN EMPIRICAL CORRECTION FOR DEAD-TIME AND PULSE PILE-UP LOSSES IN GAMMA-RAY SPECTROMETRY
    MACWANI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (01): : 122 - 126
  • [10] CORRECTIONS FOR DEAD-TIME LOSSES IN MEASUREMENT OF GAMMA-RAY SPECTRA OF SHORT-LIVED RADIONUCLIDES
    DAS, HA
    ZONDERHUIS, J
    NUCLEAR TECHNOLOGY, 1971, 10 (03) : 328 - +