A 5-year prospective multicenter study on 1-stage smooth-surface Branemark System implants with early loading in edentulous mandibles

被引:0
|
作者
Friberg, Bertil [1 ]
Raghoebar, Gerry M. [2 ]
Grunert, Ingrid [3 ]
Hobkirk, John A. [4 ]
Tepper, Gabor [5 ]
机构
[1] Clin Odontol, Branemark Clin, S-41390 Gothenburg, Sweden
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Oral & Maxillofacial Surg & Maxillofacial Pr, NL-9700 AB Groningen, Netherlands
[3] Univ Innsbruck, Dept Prosthet Dent, A-6020 Innsbruck, Austria
[4] UCL, Div Restorat Dent Sci, UCL Eastman Dent Inst, London, England
[5] Sch Dent, Dept Oral Surg, Vienna, Austria
关键词
early loading; edentulous mandible; endosseous smooth-surface implants; osseointegration;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of the current prospective multicenter Study was to evaluate the 5-year implant success and peri-implant conditions of smooth-surface Branemark System implants when using a novel technique including a 1-stage surgical procedure with early loading in edentulous mandibles. Materials and Methods: The study protocol included 1-stage surgery as well as placement of the definitive prosthesis within 6 weeks after implant insertion (ie, early loading). Clinical evaluation, as well as evaluation of function and esthetics, was performed at each follow-up visit. Radiographs were obtained at connection of the prostheses and at the 1-, 3-, and 5-year check-ups. Results: A total of 40 patients with a mean age of 56 years (range, 30 to 70) were included in the study. In all, 170 implants were placed in between the mental foramina, of which 120 implants in 30 patients were associated with overdenture treatment and 50 implants in 10 patients with fixed complete dentures. Twelve implants failed in 6 patients. The cumulative implant survival rate was 92.9% after both 1 and 5 years of follow-up. Another 3 implants were recorded as mobile but still in function when individually checked at the 5-year visit, which resulted in a cumulative success rate of 91.0%. Mean bone remodeling over the study period was less than 0.1 mm/y after the first year of loading, resulting in a mean marginal bone level of 0.66 mm (SD 0.73, n = 138) apical to the? implant collar reference point after 5 years. Conclusions. One-stage, early loaded smooth-surface Branemark System implants functioned well for the majority of patients with edentulous mandibles. Stable peri-implant conditions were observed. Bone remodeling resulted in a mean bone level above the first implant thread after 5 years. The somewhat lower success rate of 91.0% compared to a 2-stage procedure may be related to generous inclusion criteria and to a learning curve involving a novel treatment procedure.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [1] Early functional loading at 5 days for Branemark implants placed into edentulous mandibles: A prospective, open-ended, longitudinal study
    Becker, W
    Becker, BE
    Huffstetler, S
    [J]. JOURNAL OF PERIODONTOLOGY, 2003, 74 (05) : 695 - 702
  • [2] Immediate Loading of Dental Implants Inserted in Edentulous Maxillas and Mandibles: 5-Year Results of a Clinical Study
    Shigehara, Satoshi
    Ohba, Seigo
    Nakashima, Ken
    Takanashi, Yoshiaki
    Asahina, Izumi
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 701 - 705
  • [3] Early Loading of Sandblasted and Acid-Etched Titanium Implants in the Edentulous Mandible: A Prospective 5-Year Study
    Lethaus, Bernd
    Kaelber, Joerg
    Petrin, Guido
    Brandstaetter, Anita
    Weingart, Dieter
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (04) : 887 - 892
  • [4] One-year results of a prospective multicenter study on Branemark System® implants with a TiUnite™ surface
    Friberg, B
    Dahlin, C
    Widmark, G
    Östman, PO
    Billström, C
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 : S70 - S75
  • [5] Outcome of Branemark Novum® Implant Treatment in Edentulous Mandibles: A Retrospective 5-Year Follow-Up Study
    Kohal, Ralf-Joachim
    Finke, Hans Christian
    Klaus, Gerold
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (04) : 330 - 337
  • [6] Astra Tech and Branemark system implants:: a 5-year prospective study of marginal bone reactions
    Åstrand, P
    Engquist, B
    Dahlgren, S
    Gröndahl, K
    Engquist, E
    Feldmann, H
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 413 - 420
  • [7] Rehabilitation of edentulous mandibles by means of turned Branemark System® implants after one-stage surgery:: A 1-year retrospective study of 152 patients
    Friberg, B
    Henningsson, C
    Jemt, T
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 (01) : 1 - 9
  • [8] Early Loading of Implants with Fixed Dental Prostheses in Edentulous Mandibles: 7.2-Year Clinical Results from a Prospective Study
    Schwarz, Stefanie
    Bernhart, Gunda
    Eiffler, Constantin
    Hassel, Alexander Jochen
    Lehmann, Franziska
    Rammelsberg, Peter
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (06) : 904 - 912
  • [9] Early loading of implants with fixed dental prostheses in edentulous mandibles: 4.5-year clinical results from a prospective study
    Schwarz, Stefanie
    Gabbert, Olaf
    Hassel, Alexander J.
    Schmitter, Marc
    Seche, Christiane
    Rammelsberg, Peter
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (03) : 284 - 289
  • [10] A 5-Year Prospective Clinical Study of Submerged and Nonsubmerged Paragon System Implants in the Edentulous Mandible
    Eliasson, Alf
    Narby, Birger
    Ekstrand, Karl
    Hirsch, Jan
    Johansson, Anders
    Wennerberg, Ann