One-year results of a prospective multicenter study on Branemark System® implants with a TiUnite™ surface

被引:41
|
作者
Friberg, B
Dahlin, C
Widmark, G
Östman, PO
Billström, C
机构
[1] Publ Dent Hlth Serv, Clin Odontol, Branemark Clin, S-41390 Gothenburg, Sweden
[2] NAL Med Ctr Hosp, Dept Oral & Maxillofacial Surg, Trollhattan, Sweden
[3] Univ Gothenburg, Dept Biomat & Cell Biol, Gothenburg, Sweden
[4] Molndal Hosp Sweden, Dept Oral & Maxillofacial Surg, Molndal, Sweden
[5] Univ Gothenburg, Fac Odontol, Gothenburg, Sweden
[6] Univ Gothenburg, Sahlgrenska Acad, Inst Surg Sci, Dept Biomat, Gothenburg, Sweden
[7] Nobel Biocare AB, Gothenburg, Sweden
关键词
osseointegration; prospective multicenter study; rough surface;
D O I
10.1111/j.1708-8208.2005.tb00077.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: A moderately rough surface implant (TiUnite(TM), Nobel Biocare AB, Goteborg, Sweden) was introduced in 2000. Laboratory studies and some clinical studies have demonstrated excellent bone response in the early healing phase. Purpose: The aim of this prospective multicenter study was to follow a large number of consecutively treated patients using Branemark System(R) implants with the TiUnite surface. The current report constitutes the 1-year data of a planned 3-year study. Materials and Methods: Originally, the study comprised 43 surgeons from 22 centers in Sweden, Norway, and Finland. Five centers were excluded from the study because of poor compliance. Thus, 187 patients treated with 478 TiUnite implants were followed during I year of function. The majority of implants were inserted in maxillae (357 implants), and 78 of the implant sites were assigned the quality 4 figure. Radiographic evaluations were performed. Results: Five implants were lost up to and including the I-year follow-up, revealing implant cumulative survival rates of 98.6% and 100% for maxillae and mandibles, respectively. Three implants failed in quality 4 bone (3.8%). The mean marginal bone resorption at the end of the study period was 1.4 mm. The number of withdrawals of patients during the first year was high (19.3%). Conclusion: The present investigation showed a high implant cumulative survival rate of 98.9%. Values of marginal bone resorption were within normal ranges. No adverse effects of the TiUnite surface were reported, and complications during the study period were few and similar to those reported for the turned implant surface. However, the high number of excluded patients and the relatively high number of withdrawals must be observed and considered when interpreting data.
引用
收藏
页码:S70 / S75
页数:6
相关论文
共 50 条
  • [1] One-Year Results of a Clinical and Radiological Prospective Multicenter Study on NEOSS® Dental Implants
    Dahlin, Christer
    Widmark, Goran
    Bergkvist, Goran
    Furst, Bjorn
    Widbom, Tor
    Kashani, Hossein
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (02) : 303 - 308
  • [2] Immediate occlusal loading of Branemark System® TiUnite™ implants placed predominantly in soft bone:: 4-year results of a prospective clinical study
    Glauser, R
    Ruhstaller, P
    Windisch, S
    Zembic, A
    Lundgren, A
    Gottlow, J
    Hämmerle, CHF
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 : S52 - S59
  • [3] Mandibular overdentures supported by two Branemark, IMZ or ITI implants - A prospective comparative preliminary study: One-year results
    Batenburg, RHK
    Meijer, HJA
    Raghoebar, GM
    Van Oort, RP
    Boering, G
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (06) : 374 - 383
  • [4] One-year results of a prospective multicenter study of the Casebeer system of refractive keratotomy
    Waring, GO
    Casebeer, JC
    Dru, RM
    Allen, R
    Moore, C
    Werblin, T
    Berg, JC
    Phillips, S
    Whitson, W
    Price, F
    Waring, G
    Cole, R
    Rapoza, P
    Dru, R
    Couch, J
    Robin, J
    Gordon, J
    Hale, L
    Rothchild, E
    Lasswell, L
    Harman, RL
    Somers, M
    Lee, P
    Hettinger, M
    Steinert, R
    [J]. OPHTHALMOLOGY, 1996, 103 (09) : 1337 - 1347
  • [5] One-step surgical placement of Branemark implants: A prospective multicenter clinical study
    Becker, W
    Becker, BE
    Israelson, H
    Lucchini, JP
    Handelsman, M
    Ammons, W
    Rosenberg, E
    Rose, L
    Tucker, LM
    Lekholm, U
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (04) : 454 - 462
  • [6] ONE-YEAR OUTCOME OF FISSURECTOMY: A PROSPECTIVE, MULTICENTER STUDY
    Bouchard, D.
    Souffran, M.
    Devulder, F.
    Ganansia, R.
    Castinel, A.
    Staumont, G.
    Suduca, J.
    Soudan, D.
    Pigot, F.
    Guyot, P.
    Abramowitz, L.
    [J]. DISEASES OF THE COLON & RECTUM, 2010, 53 (04) : 587 - 588
  • [7] Immediate Occlusal Loading of Single Lower Molars Using Branemark System® Wide Platform TiUnite™ Implants: A 5-Year Follow-Up Report of a Prospective Clinical Multicenter Study
    Calandriello, Roberto
    Tomatis, Massimiliano
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (04) : 311 - 318
  • [8] Immediate loading of implants with mandibular overdentures: One-year clinical results of a prospective study
    Attard, NJ
    David, LA
    Zarb, GA
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2005, 18 (06) : 463 - 470
  • [9] Facet Arthrodesis with the FFX Device: One-Year Results from a Prospective Multicenter Study
    Srour, Robin
    Gdoura, Yassine
    Delaitre, Mariette
    Mortada, Jihad
    Benali, Mustapha Ali
    Millot, Fabrice
    Hritcu, Daniel
    Timofeev, Alexandre
    Sellal, Francois
    [J]. INTERNATIONAL JOURNAL OF SPINE SURGERY, 2020, 14 (06): : 996 - 1002
  • [10] A 5-year prospective multicenter study on 1-stage smooth-surface Branemark System implants with early loading in edentulous mandibles
    Friberg, Bertil
    Raghoebar, Gerry M.
    Grunert, Ingrid
    Hobkirk, John A.
    Tepper, Gabor
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (03) : 481 - 486