Immediate Occlusal Loading of Single Lower Molars Using Branemark System® Wide Platform TiUnite™ Implants: A 5-Year Follow-Up Report of a Prospective Clinical Multicenter Study

被引:52
|
作者
Calandriello, Roberto
Tomatis, Massimiliano
机构
[1] Bologna
[2] Bologna
关键词
immediate load; occlusal load; single molar; smokers; TiUnite (TM); un-splinted; wide platform;
D O I
10.1111/j.1708-8208.2009.00214.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Although not essential, molars hold their importance in terms of functional jaw stability, antagonist opposition, and support of facial height. Therefore, implant therapy is an attractive concept in molar areas. However, especially in the posterior mandible, the conventional two-stage surgical approach to implant therapy was reported to cause higher bone loss and/or higher implant failures with machined implants because of the peculiar anatomic and physiologic conditions of this area. As the TiUnite (TM) (Nobel Biocare AB, GOteborg, Sweden) surface results in faster bone healing than with machined-surface implants, it was hypothesized that this surface would also improve the performance of wide implants in posterior mandibles. Based on these assumptions, a protocol for immediately loaded implants for single molar replacement was developed. Purpose: This paper aimed to report on the clinical and radiological performance of Branemark System(R) TiUnite Wide Platform implants supporting single molars in the lower jaw, loaded immediately and followed for up to 5 years, and to assess if the benefit delivered by oxidized surfaces in the short run is also present after 5 years. Materials and Methods: The study includes 33 consecutive patients treated between March 2001 and September 2003 and monitored until September 2008 in two private dental offices. A total of 40 Branemark System TiUnite Wide Platform MK III implants were placed. All implants were provided with provisional crowns in full centric occlusion at the time of surgery. Patients were clinically and radiologically followed up for up to 5 years. Results: Two implant failed so that the cumulative success rate at 5 years was 95.0%. The mean marginal bone remodeling (n = 38) expressed as mesial plus distal value averages was -1.17 mm (SD +/- 0.90) at the 5-year time point. Conclusion: Although limited by the number of patients treated in accordance with the protocol described, 5-year results encourage the use of immediately loaded single lower molars supported by Branemark System Wide Platform TiUnite implants and further document the clinical advantages of titanium oxidized surfaces.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [1] Immediate occlusal loading of Branemark System® TiUnite™ implants placed predominantly in soft bone:: 4-year results of a prospective clinical study
    Glauser, R
    Ruhstaller, P
    Windisch, S
    Zembic, A
    Lundgren, A
    Gottlow, J
    Hämmerle, CHF
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 : S52 - S59
  • [2] Immediate functional loading of Branemark single tooth implants - An 18 months' clinical pilot follow-up study
    Ericsson, I
    Nilson, H
    Lindh, T
    Nilner, K
    Randow, K
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (01) : 26 - 33
  • [3] Long-Term Retrospective Clinical and Radiographic Follow-up of 205 Branemark System Mk III TiUnite Implants Submitted to Either Immediate or Delayed Loading
    Imburgia, Mario
    Del Fabbro, Massimo
    [J]. IMPLANT DENTISTRY, 2015, 24 (05) : 533 - 540
  • [4] Immediate functional loading of Branemark dental implants - An 18-month clinical follow-up study
    Randow, K
    Ericsson, I
    Nilner, K
    Petersson, A
    Glantz, PO
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (01) : 8 - 15
  • [5] Prefabricated Bar System for Immediate Loading in Edentulous Patients: A 5-Year Follow-Up Prospective Longitudinal Study
    Gherlone, Enrico F.
    Sannino, Gianpaolo
    Rapanelli, Andrea
    Crespi, Roberto
    Gastaldi, Giorgio
    Cappare, Paolo
    [J]. BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [6] Implants in fresh extraction sockets: a prospective 5-year follow-up clinical study
    Botticelli, Daniele
    Renzi, Antonio
    Lindhe, Jan
    Berglundh, Tord
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (12) : 1226 - 1232
  • [7] Immediate Loading of Branemark System TiUnite and Machined-Surface Implants in the Posterior Mandible, Part II: A Randomized Open-Ended 9-Year Follow-up Clinical Trial
    Rocci, Antonio
    Rocci, Marta
    Rocci, Cecilia
    Scoccia, Andrea
    Gargari, Marco
    Martignoni, Massimiliano
    Gottlow, Jan
    Sennerby, Lars
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : 891 - 895
  • [8] A 3-year prospective multicenter follow-up report on the immediate and delayed-immediate placement of implants
    Grunder, U
    Polizzi, G
    Goené, R
    Hatano, N
    Henry, P
    Jackson, WJ
    Kawamura, K
    Köhler, S
    Renouard, F
    Rosenberg, R
    Triplett, G
    Werbitt, M
    Lithner, B
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (02) : 210 - 216
  • [9] Immediate functional loading of single implants: A 1-year interim report of a 5-year prospective multicentre study
    Luongo, Giuseppe
    Lenzi, Carolina
    Raes, Filiep
    Eccellente, Tammaro
    Ortolani, Michele
    Mangano, Carlo
    [J]. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (02) : 187 - 199
  • [10] Clinical and radiographic evaluation of early loaded narrow-diameter implants: 5-year follow-up of a multicenter prospective clinical study
    Galindo-Moreno, Pablo
    Nilsson, Peter
    King, Paul
    Worsaae, Nils
    Schramm, Alexander
    Padial-Molina, Miguel
    Maiorana, Carlo
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (12) : 1584 - 1591