Immediate functional loading of Branemark single tooth implants - An 18 months' clinical pilot follow-up study

被引:182
|
作者
Ericsson, I
Nilson, H
Lindh, T
Nilner, K
Randow, K
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthet Dent, S-21421 Malmo, Sweden
[2] Umea Univ, Umea, Sweden
关键词
1-stage procedure; clinical examination; immediate loading; radiographical examination; single dental implants;
D O I
10.1034/j.1600-0501.2000.011001026.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A clinical and radiographical study was performed to evaluate the treatment outcome of single tooth replacements with artificial crowns retained to implants installed according to a 1-stage surgical procedure and immediate loading (Experimental Group=EG) in comparison to the original 2-stage concept (Control Group=CG). The EG comprised 14 patients (=14 implants) and the CG comprised 8 patients (= 8 implants), all with single tooth losses anterior to the molars. Beyond the non-smoking criterion the following criteria were adopted: i) the amount of bone had to allow for installation of a fixture with a minimum length of 13 mm and diameter = 3.75 mm, ii) the jaw relationship had to allow for bilateral occlusal stability, iii) the patients should be judged to be non-bruxers, and iv) the patients had to be available for the follow-up and maintenance programme. In the EG a temporary crown was connected to the implant within 24 h following fixture installation. Six months later this crown was replaced with a permanent one. In the CG the surgical and prosthetic treatment followed the standard protocol. Out of the 14 fixtures in the EG 2 were lost up to 5 months in function and were subsequently removed. All remaining 12 implants were stable at every subsequent follow-up examination. No fixture losses were recorded in the CG and all implants in this group were stable at the follow-ups. At the 6-month observation interval all the participating 20 patients were radiographically examined, an examination that was repeated at the 18-month follow-up. The analysis of the radiographs from the EG as well as from the CG disclosed that during the Ii-month observation period the mean change of bone support was about 0.1 mm. Further studies, designed as controlled multicenter ones, have to be performed before the results of this pilot study can be recommended for more general use.
引用
收藏
页码:26 / 33
页数:8
相关论文
共 50 条
  • [1] Immediate functional loading of Branemark dental implants - An 18-month clinical follow-up study
    Randow, K
    Ericsson, I
    Nilner, K
    Petersson, A
    Glantz, PO
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (01) : 8 - 15
  • [2] Retrospective Study on Immediate Functional Loading of Edentulous Maxillas and Mandibles With 690 Implants, Up to 71 Months of Follow-Up
    Li, William
    Chow, James
    Hui, Edward
    Lee, P. K. M.
    Chow, Raymond
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (12) : 2653 - 2662
  • [3] A long-term follow-up of 76 Branemark single-tooth implants
    Haas, R
    Polak, C
    Fürhauser, R
    Mailath-Pokorny, G
    Dörtbudak, O
    Watzek, G
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (01) : 38 - 43
  • [4] Single Osseointegrated dental implants and immediate non-functional loading: A 6- to 24 months follow-up study of 49 titanium implants
    Tsirlis, A
    Veis, A
    Maroufidis, N
    Parissis, N
    [J]. PROCEEDINGS OF THE MEDITERRANEAN DENTAL IMPLANT CONGRESS 2004, 2004, : 49 - 53
  • [5] Immediate functional loading of implants in single tooth replacement: a prospective clinical multicenter study
    Donati, Mauro
    La Scala, Vincenzo
    Billi, Mauro
    Di Dino, Biagio
    Torrisi, Paolo
    Berglundh, Tord
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (08) : 740 - 748
  • [6] Comparative analysis study of 702 dental implants subjected to immediate functional loading and immediate nonfunctional loading to traditional healing periods with a follow-up of up to 24 months
    Degidi, M
    Piattelli, A
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (01) : 99 - 107
  • [7] IMMEDIATE LOADING; THREE CASES WITH UP TO 38 MONTHS OF CLINICAL FOLLOW-UP
    Bilhan, Hakan
    Sonmez, Esma
    Mumcu, Emre
    Bilgin, Tayfun
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2009, 35 (02) : 75 - 81
  • [8] Early functional loading of conical Branemark implants in the edentulous mandible:: A 12-month follow-up clinical report
    Kronström, M
    Widbom, T
    Löfquist, LE
    Henningson, C
    Widbom, C
    Lundberg, T
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (04): : 335 - 340
  • [9] A prospective clinical evaluation of different single-tooth restoration designs on osseointegrated implants - A 3-year follow-up of Branemark implants
    Wannfors, K
    Smedberg, JI
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (06) : 453 - 458
  • [10] Immediate Occlusal Loading of Single Lower Molars Using Branemark System® Wide Platform TiUnite™ Implants: A 5-Year Follow-Up Report of a Prospective Clinical Multicenter Study
    Calandriello, Roberto
    Tomatis, Massimiliano
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (04) : 311 - 318