Intraobserver and interobserver reproducibility of ovarian volume, antral follicle count, and vascularity indices obtained with transvaginal 3-dimensional ultrasonography, power Doppler angiography, and the virtual organ computer-aided analysis imaging program

被引:48
|
作者
Mercé, LT
Gómez, B
Engels, V
Bau, S
Bajo, JM
机构
[1] Int Ruber Hosp, Madrid, Spain
[2] Univ Hosp Santa Cristina, Madrid, Spain
关键词
ovary; reproducibility; 3-dimensional power Doppler angiography; 3-dimensional ultrasonography; vascularity indices; Virtual Organ Computer-Aided Analysis;
D O I
10.7863/jum.2005.24.9.1279
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives. The purpose of this study was to assess intraobserver and interobserver reproducibility of the parameters of ovarian response and oocyte ability, studied by 3-dimensional ultrasonography and power Doppler angiography (PDA), and the possible influence of the ovarian functional stage. Methods. Twenty-nine women were included in an in vitro fertilization program. Fourteen women were evaluated after pituitary suppression (basal group), and 15 were scanned on the human chorionic gonadotropin administration day, after gonadotropin ovarian stimulation (stimulated group). A first observer acquired 2 volumes for each ovary. Another observer performed a second analysis of the volumes acquired by the first observer. We analyzed ovarian volume, follicle number in the basal group, vascularization index, flow index, and vascularization-flow index. The volumes were processed by the Virtual Organ Computer-Aided Analysis imaging program using plane A and 15 degrees rotational steps. Results. Ovarian volume showed excellent intraobserver and interobserver agreement, with an intraclass correlation coefficient (Intra-CC) and an interclass correlation coefficient (inter-CC) close to the unit. The Intra-CC and Inter-CC about the number of follicles were 0.964 and 0.978, respectively Vascularity indices showed an Intra-CC greater than 0.90. The vascularization index and the vascularization-flow index showed higher interobserver than intraobserver reproducibility (inter-CC > 0.96 for both). The flow index Inter-CC was 0.898. The reproducibility differences between the basal and stimulated ovary measurements were not significant. Conclusions. There is an excellent intraobserver and interobserver reproducibility of the ovarian volume, follicle counts, and 3-dimensional PDA indices. The ovarian functional stage has no influence on the reliability. Three-dimensional ultrasonography and PDA improve the study of ovarian parameters, and their reliability impels a change in the current clinical routine of performing and interpreting ultrasonography. Key words: ovary; reproducibility; 3-dimensional power
引用
收藏
页码:1279 / 1287
页数:9
相关论文
共 16 条
  • [1] The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders
    S. C. Chiou
    M. H. Hsieh
    H. Y. Chen
    J. D. Lin
    C. C. Chen
    W. H. Hsu
    L. B. Jeng
    C. T. Chang
    R. H. Chen
    T. Y. Wang
    W. L. Haung
    [J]. Journal of Endocrinological Investigation, 2009, 32 : 139 - 146
  • [2] The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders
    Chiou, S. -C.
    Hsieh, M. -H.
    Chen, H. -Y.
    Lin, J. -D.
    Chen, C. -C.
    Hsu, W. -H.
    Jeng, L. -B.
    Chang, C. -T.
    Chen, R. -H.
    Wang, T. -Y.
    Haung, W. -L.
    [J]. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2009, 32 (02) : 139 - 146
  • [3] Endometrial volume and vascularity measurements by transvaginal 3-dimensional ultrasonography and power Doppler angiography in stimulated and tumoral endometria -: An interobserver reproducibility study
    Alcázar, JL
    Mercé, LT
    Manero, MG
    Bau, S
    López-García, G
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (08) : 1091 - 1098
  • [4] Endometrial volume and vascularity measurements by transvaginal three-dimensional ultrasonography and power Doppler angiography in stimulated and tumoral endometria:: Intraobserver reproducibility
    Mercé, LT
    Alcázar, JL
    Engels, V
    Troyano, J
    Bau, S
    Bajo, JM
    [J]. GYNECOLOGIC ONCOLOGY, 2006, 100 (03) : 544 - 550
  • [5] Intraobserver and interobserver variability of ovarian volume, gray-scale and color flow indices obtained using transvaginal three-dimensional power Doppler ultrasonography
    Järvelä, IY
    Sladkevicius, P
    Tekay, AH
    Campbell, S
    Nargund, G
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 21 (03) : 277 - 282
  • [6] Reproducibility of transvaginal three-dimensional endometrial volume measurements with virtual organ computer-aided analysis (VOCAL) during ovarian stimulation
    Bordes, A
    Bory, AM
    Benchaïb, M
    Rudigoz, RC
    Salle, B
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 19 (01) : 76 - 80
  • [7] Intra- and interobserver agreement on cervical volume and flow indices during pregnancy using transvaginal 3-dimensional ultrasonography and Doppler angiography
    Basgul, Alin
    Kavak, Zehra N.
    Bakird, Nadi
    Gokaslan, Husnu
    [J]. INTERNATIONAL JOURNAL OF FERTILITY AND WOMENS MEDICINE, 2006, 51 (06) : 256 - 261
  • [8] Reliability and Validity of In Vitro Volume Calculations by 3-Dimensional Ultrasonography Using the Multiplanar, Virtual Organ Computer-Aided Analysis (VOCAL), and Extended Imaging VOCAL Methods
    de Sa Barreto, Enoch Quindere
    Figuinha Milani, Herbene Jose
    Araujo Junior, Edward
    Haratz, Karina Krajden
    Rolo, Liliam Cristine
    Machado Nardozza, Luciano Marcondes
    Moron, Antonio Fernandes
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (05) : 767 - 774
  • [9] Inapplicability of fractional moving blood volume technique to standardize Virtual Organ Computer-aided AnaLysis indices for quantified three-dimensional power Doppler
    Welsh, A. W.
    Collins, S. L.
    Stevenson, G. N.
    Noble, J. A.
    Impey, L.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (06) : 688 - 692
  • [10] A nomogram of fetal lung volumes estimated by 3-dimensional ultrasonography using the rotational technique (virtual organ computer-aided analysis)
    Ruano, R
    Joubin, L
    Aubry, MC
    Thalabard, JC
    Dommergues, M
    Dumez, Y
    Benachi, A
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (06) : 701 - 709