Inapplicability of fractional moving blood volume technique to standardize Virtual Organ Computer-aided AnaLysis indices for quantified three-dimensional power Doppler

被引:15
|
作者
Welsh, A. W. [1 ,2 ]
Collins, S. L. [3 ,4 ]
Stevenson, G. N. [5 ]
Noble, J. A. [5 ]
Impey, L. [3 ,4 ]
机构
[1] Royal Hosp Women, Dept Maternal Fetal Med, Randwick, NSW 2031, Australia
[2] Univ New S Wales, Sch Womens & Childrens Hlth, Randwick, NSW, Australia
[3] Univ Oxford, Nuffield Dept Obstet & Gynaecol, Oxford, England
[4] John Radcliffe Hosp, Fetal Med Unit, Oxford OX3 9DU, England
[5] Univ Oxford, Dept Engn Sci, Inst Biomed Engn, Oxford OX1 3PJ, England
关键词
Doppler; fetus; fractional moving blood volume; placenta; ultrasound; VOCAL; FLOW; ANGIOGRAPHY; ULTRASOUND; PERFUSION; GAIN;
D O I
10.1002/uog.11139
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To determine whether the technique of fractional moving blood volume (FMBV) is applicable to Virtual Organ Computer-aided AnaLysis II (VOCAL II (TM))-based indices to quantify three-dimensional power Doppler ultrasound (3D-PDU) by investigating the effect of gain level on the indices measured at a possible reference point for standardization. Methods Ten women with singleton pregnancy between 33 + 3 and 37 + 5 weeks' gestation were recruited. The optimal position for 3D acquisition of cord insertion into the placenta was identified and static 3D-PDU volumes were acquired using consistent machine configurations. Without moving the probe or the participant changing position, successive 3D volumes were stored at -3, 5, 7 and -9 dB and at the individualized sub-noise gain (SNG) level. Volumes were excluded if flash artifact was present, in which case all five volumes were reacquired. Using 4D View software, the cord insertion was magnified and the smallest sphere possible was used to measure vascularization index (VI), flow index (FI) and vascularization flow index (VFI). The associations between VOCAL indices and gain level were assessed using Pearson's correlation coefficient. Results VOCAL indices for cord insertion correlated poorly with gain level, whether fundamental or relative to SNG level (R2 = 0.07 and 0.04, respectively). VI was consistently 100% and mean FI and VFI were 99.5 (SD, 0.57), with all values > 97 irrespective of gain level. Conclusions Whilst previous work has shown that gain correlates well with placental tissue VOCAL indices, the correlation between gain level and VOCAL indices in an area of 100% vascularity at the cord insertion is poor. Regions of 100% vascularity appear to be artificially assigned a value approaching 100% for all VOCAL indices irrespective of gain level. This precludes using the technique of VOCAL indices from large vessels to standardize power Doppler measurements and the FMBV index is therefore not applicable to image analysis using VOCAL.
引用
收藏
页码:688 / 692
页数:5
相关论文
共 30 条
  • [1] Three-Dimensional Ultrasonographic Bladder Volume Measurement Reliability of the Virtual Organ Computer-Aided Analysis Technique Using Different Rotation Steps
    Suwanrath, Chitkasaem
    Suntharasaj, Thitima
    Sirapatanapipat, Hemmasak
    Geater, Alan
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (07) : 847 - 854
  • [2] Assessment of renal volume by three-dimensional ultrasonography in pregnant bitches: an experimental study using virtual organ computer-aided analysis
    Débora Sartori Mendonça
    Rafael Fontoura Fernandes Moron
    André Luiz Louzada Maldonado
    Edward Araujo
    Luciano Marcondes Machado Nardozza
    Antonio Fernandes Moron
    [J]. BMC Veterinary Research, 8
  • [3] Assessment of renal volume by three-dimensional ultrasonography in pregnant bitches: an experimental study using virtual organ computer-aided analysis
    Mendonca, Debora Sartori
    Fernandes Moron, Rafael Fontoura
    Louzada Maldonado, Andre Luiz
    Araujo Junior, Edward
    Machado Nardozza, Luciano Marcondes
    Moron, Antonio Fernandes
    [J]. BMC VETERINARY RESEARCH, 2012, 8
  • [4] MEASURING FETAL VOLUME DURING LATE FIRST TRIMESTER BY THREE-DIMENSIONAL ULTRASONOGRAPHY USING VIRTUAL ORGAN COMPUTER-AIDED ANALYSIS
    Barra, Daniela A.
    Lima, Jailson C.
    Mauad Filho, Francisco
    Araujo Junior, Edward
    Martins, Wellington P.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (09): : 1552 - 1559
  • [5] Reproducibility of transvaginal three-dimensional endometrial volume measurements with virtual organ computer-aided analysis (VOCAL) during ovarian stimulation
    Bordes, A
    Bory, AM
    Benchaïb, M
    Rudigoz, RC
    Salle, B
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 19 (01) : 76 - 80
  • [6] Assessment of placental fractional moving blood volume using quantitative three-dimensional power Doppler ultrasound
    Yu, CH
    Chang, CH
    Ko, HC
    Chen, WC
    Chang, FM
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (01): : 19 - 23
  • [7] Original Research n Technical Developments A Technique for the Estimation of Fractional Moving Blood Volume by Using Three-dimensional Power Doppler US
    Stevenson, Gordon N.
    Collins, Sally L.
    Welsh, Alec W.
    Impey, Lawrence W.
    Noble, J. Alison
    [J]. RADIOLOGY, 2015, 274 (01) : 230 - 237
  • [8] Nomogram of fetal upper arm volume by three-dimensional ultrasound using extended imaging virtual organ computer-aided analysis (XI VOCAL)
    Cavalcante, Rafael Oliveira
    Araujo Junior, Edward
    Machado Nardozza, Luciano Marcondes
    Rolo, Liliam Cristine
    Moron, Antonio Fernandes
    [J]. JOURNAL OF PERINATAL MEDICINE, 2011, 39 (06) : 717 - 724
  • [9] The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders
    Chiou, S. -C.
    Hsieh, M. -H.
    Chen, H. -Y.
    Lin, J. -D.
    Chen, C. -C.
    Hsu, W. -H.
    Jeng, L. -B.
    Chang, C. -T.
    Chen, R. -H.
    Wang, T. -Y.
    Haung, W. -L.
    [J]. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2009, 32 (02) : 139 - 146
  • [10] The reproducibility of the virtual organ computer-aided analysis program for evaluating 3-dimensional power Doppler ultrasonography of diffuse thyroid disorders
    S. C. Chiou
    M. H. Hsieh
    H. Y. Chen
    J. D. Lin
    C. C. Chen
    W. H. Hsu
    L. B. Jeng
    C. T. Chang
    R. H. Chen
    T. Y. Wang
    W. L. Haung
    [J]. Journal of Endocrinological Investigation, 2009, 32 : 139 - 146