Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws

被引:46
|
作者
Weimann, A
Rodieck, M
Zantop, T
Hassenpflug, J
Petersen, W
机构
[1] Univ Munster, Dept Trauma Hand & Reconstruct Surg, D-48149 Munster, Germany
[2] Univ Kiel, Dept Orthopaed Surg, D-24098 Kiel, Germany
关键词
hamstring graft fixation; biomechanics; maximal load; tensile stress; failure mode; cyclic testing;
D O I
10.1016/j.arthro.2004.10.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: During the early postoperative period, the stability of the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. The aim of this study was to evaluate if the initial fixation strength of a new suspension screw is comparable to that of the biodegradable interference screw fixation technique in the hamstring reconstruction of the anterior cruciate ligament (ACL). Type of Study: Experimental laboratory study. Methods: We evaluated the initial fixation strength of a biodegradable poly-L-lactide/tri-calcium phosphate (PLLA/TCP) screw that suspended the graft in the bone tunnel and compared it with the strength of an interference screw for fixation of hamstring grafts in ACL reconstruction using bovine knees. Single-cycle and cyclic loading tests were performed using a materials testing machine. Results: The suspension screw provided a significantly higher yield load and ultimate failure load than the interference screw. There was no significant difference in the stiffness of both techniques. The typical failure mode for the suspension screw was fracture of the screw and for the interference screw it was slippage of the graft past the screw. In cyclic testing, both methods of fixation ran out to 1,000 cycles up to 250 N with a mean displacement of 2.6 mm (range, 1.8 to 3.3 mm) for the suspension screw and 4.1 mm (range, 2.3 to 6.0 mm) for the interference screw. Only the grafts fixed with the suspension screw survived a protocol with 1,000 cycles up to 400 N. Conclusions: Our biomechanical data suggest that hamstring graft fixation using a biodegradable PLLA/TCP suspension screw provides an alternative to interference screw fixation. Clinical Relevance: Hamstring graft fixation using a suspension screw provides a reasonable alternative to interference screw fixation.
引用
收藏
页码:266 / 274
页数:9
相关论文
共 50 条
  • [1] Biomechanical testing of hamstring graft tibial tunnel fixation with bioabsorbable interference screws
    Caborn, DNM
    Nyland, J
    Selby, J
    Tetik, O
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09): : 991 - 996
  • [2] Ligament graft initial fixation strength using biodegradable interference screws
    Rupp, S
    Seil, R
    Schneider, A
    Kohn, DM
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1999, 48 (01): : 70 - 74
  • [3] Interference screws should be shorter than the hamstring tendon graft in the bone tunnel for best fixation
    Stalder, Michael
    Farshad, Mazda
    Snedeker, Jess G.
    Meyer, Dominik C.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (03) : 584 - 588
  • [4] Interference screws should be shorter than the hamstring tendon graft in the bone tunnel for best fixation
    Michael Stalder
    Mazda Farshad
    Jess G. Snedeker
    Dominik C. Meyer
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 584 - 588
  • [5] Correlation of bone tunnel diameter with quadrupled hamstring graft fixation strength using a biodegradable interference screw
    Steenlage, E
    Brand, JC
    Johnson, DL
    Caborn, DNM
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (08): : 901 - 907
  • [6] Quadruple Hamstring Anterior Cruciate Ligament Fixation Using Interference Screws
    Scranton, Pierce E., Jr.
    TECHNIQUES IN ORTHOPAEDICS, 2005, 20 (03) : 261 - 263
  • [7] Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction
    Debieux, Pedro
    Franciozi, Carlos E. S.
    Lenza, Mario
    Tamaoki, Marcel Jun
    Magnussen, Robert A.
    Faloppa, Flavio
    Belloti, Joao Carlos
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (07):
  • [8] Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws - Influence of screw length
    Stadelmaier, DM
    Lowe, WR
    Ilahi, OA
    Noble, PC
    Kohl, HW
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (06): : 778 - 783
  • [9] Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone
    Weiler, A
    Hoffmann, RFG
    Stahelin, AC
    Bail, HJ
    Siepe, CJ
    Sudkamp, NP
    ARTHROSCOPY, 1998, 14 (01): : 29 - 37
  • [10] Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
    McGuire, DA
    Barber, FA
    Elrod, BF
    Paulos, LE
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (05): : 463 - 473