Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws

被引:46
|
作者
Weimann, A
Rodieck, M
Zantop, T
Hassenpflug, J
Petersen, W
机构
[1] Univ Munster, Dept Trauma Hand & Reconstruct Surg, D-48149 Munster, Germany
[2] Univ Kiel, Dept Orthopaed Surg, D-24098 Kiel, Germany
关键词
hamstring graft fixation; biomechanics; maximal load; tensile stress; failure mode; cyclic testing;
D O I
10.1016/j.arthro.2004.10.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: During the early postoperative period, the stability of the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. The aim of this study was to evaluate if the initial fixation strength of a new suspension screw is comparable to that of the biodegradable interference screw fixation technique in the hamstring reconstruction of the anterior cruciate ligament (ACL). Type of Study: Experimental laboratory study. Methods: We evaluated the initial fixation strength of a biodegradable poly-L-lactide/tri-calcium phosphate (PLLA/TCP) screw that suspended the graft in the bone tunnel and compared it with the strength of an interference screw for fixation of hamstring grafts in ACL reconstruction using bovine knees. Single-cycle and cyclic loading tests were performed using a materials testing machine. Results: The suspension screw provided a significantly higher yield load and ultimate failure load than the interference screw. There was no significant difference in the stiffness of both techniques. The typical failure mode for the suspension screw was fracture of the screw and for the interference screw it was slippage of the graft past the screw. In cyclic testing, both methods of fixation ran out to 1,000 cycles up to 250 N with a mean displacement of 2.6 mm (range, 1.8 to 3.3 mm) for the suspension screw and 4.1 mm (range, 2.3 to 6.0 mm) for the interference screw. Only the grafts fixed with the suspension screw survived a protocol with 1,000 cycles up to 400 N. Conclusions: Our biomechanical data suggest that hamstring graft fixation using a biodegradable PLLA/TCP suspension screw provides an alternative to interference screw fixation. Clinical Relevance: Hamstring graft fixation using a suspension screw provides a reasonable alternative to interference screw fixation.
引用
收藏
页码:266 / 274
页数:9
相关论文
共 50 条
  • [31] Comparison of Fixation Stability of Resorbable Versus Titanium Plate and Screws in Mandibular Angle Fractures
    Bayram, Burak
    Araz, Kenan
    Uckan, Sina
    Balcik, Cenk
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (08) : 1644 - 1648
  • [32] Clinical outcome of anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft and bioabsorbable interference screw fixation
    Charlton, WPH
    Randolph, DA
    Lemos, S
    Shields, CL
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (04): : 518 - 521
  • [33] The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro
    Camilla Halewood
    Michael T. Hirschmann
    Simon Newman
    Jaffar Hleihil
    Gershon Chaimski
    Andrew A. Amis
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 559 - 567
  • [34] The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro
    Halewood, Camilla
    Hirschmann, Michael T.
    Newman, Simon
    Hleihil, Jaffar
    Chaimski, Gershon
    Amis, Andrew A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (04) : 559 - 567
  • [35] In situ comparison of varying composite tibial tunnel interference screws used for ACL soft tissue graft fixation
    Nyland, John
    Krupp, Ryan
    Greene, Joe
    Bowles, Richard
    Burden, Robert
    Caborn, David N. M.
    KNEE, 2015, 22 (06): : 554 - 558
  • [36] Cross Pin Versus Interference Screw for Femoral Graft Fixation in Hamstring Anterior Cruciate Ligament Reconstruction: A Systematic Review and Meta-analysis of Clinical Outcomes
    Hu, Bin
    Shen, Weiliang
    Zhou, Chenhe
    Meng, Jiahong
    Wu, Haobo
    Yan, Shigui
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (02): : 615 - 623
  • [37] Tendon-to-bone healing of a quadrupled hamstring tendon graft fixed with biodegradable screws in an immature athlete: A radiologic, arthroscopic, histologic, and electromicroscopic investigation
    Fankhauser, F
    Passler, JM
    Schippinger, G
    Boldin, C
    Scarpatetti, M
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (09): : 992 - 997
  • [38] Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque
    Brand, JC
    Pienkowski, D
    Steenlage, E
    Hamilton, D
    Johnson, DL
    Caborn, DNM
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05): : 705 - 710
  • [39] The biomechanics of biodegradable versus titanium interference screw fixation for anterior cruciate ligament augmentation and reconstruction
    Ettinger, Max
    Schumacher, Diana
    Calliess, Tilman
    Dratzidis, Antonios
    Ezechieli, Marco
    Hurschler, Christof
    Becher, Christoph
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (12) : 2499 - 2503
  • [40] Combined Anterior Cruciate Ligament and Posterolateral Corner Reconstruction by Hamstring Tendon Autografts Through a Single Femoral Tunnel by Graft-to-Graft Suspension and Fixation
    Selim, Naser M.
    ARTHROSCOPY TECHNIQUES, 2018, 7 (05): : E457 - +