Controllable preparation of a reverse-phase/hydrophilic interaction mixed-mode chromatographic stationary phase with adjustable selectivity

被引:5
|
作者
Bo, Chunmiao [1 ,2 ]
Dai, Xiaojun [1 ,2 ]
Chen, Weimin [3 ]
Cao, Rui [2 ]
机构
[1] Ningxia Univ, State Key Lab High Efficiency Utilizat Coal & Gre, Yinchuan 750021, Peoples R China
[2] Ningxia Univ, Coll Chem & Chem Engn, Yinchuan 750021, Ningxia, Peoples R China
[3] Ningxia Univ, Inst Environm Engn, Yinchuan 750021, Ningxia, Peoples R China
基金
中国国家自然科学基金;
关键词
INTERACTION LIQUID-CHROMATOGRAPHY; HYDROPHILIC INTERACTION; RADICAL POLYMERIZATION; MODIFIED-SILICA; CATION-EXCHANGE; BONDED SILICA; SURFACE;
D O I
10.1039/c8ay01944d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selectivity is very important for stationary phase applications. However, selectivity is usually quite difficult to adjustonce the ligands are fixed. Departing from the reported methods, dodecyl methacrylate (DOMA) and hydroxyethyl methacrylate (HEMA) were grafted onto a silica surface via two-step surface initiated-atom transfer radical polymerization (SI-ATRP) to synthesize reverse-phase/hydrophilic interaction mixed-mode stationary phases. The grafted amounts of C12 and OH functional groups were controlled by varying the ratios of DOMA to HEMA in the polymerization system. The resulting stationary phases were characterized by transmission electron microscopy (TEM), solid-state C-13 NMR spectroscopy, elemental analysis (EA), Fourier transform infrared (FT-IR) spectrometry, and thermogravimetric analysis (TGA). The chromatographic performance and separation selectivity of the packed columns were investigated in different chromatographic modes using a wide range of analytes, including a non-polar benzene series, moderately polar -agonists as well as organic acids, and strongly polar nucleosides. Exceptionally, the retention of the tested analytes displayed an obvious dependence on the ratio of the two functional monomers in the polymerization. In conclusion, the proposed strategy for the development of a mixed-mode chromatographic stationary phase can provide flexible selectivity by simply tuning the ratios of functional monomers.
引用
收藏
页码:5387 / 5397
页数:11
相关论文
共 50 条
  • [21] Glutathione-based zwitterionic stationary phase for hydrophilic interaction/cation-exchange mixed-mode chromatography
    Shen, Aijin
    Li, Xiuling
    Dong, Xuefang
    Wei, Jie
    Guo, Zhimou
    Liang, Xinmiao
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1314 : 63 - 69
  • [22] SEPARATION PROPERTIES OF A MIXED-MODE STATIONARY PHASE: HYDROPHILIC INTERACTION LIQUID CHROMATOGRAPHY SEPARATION OF B-VITAMINS
    Aral, Tarik
    Aral, Hayriye
    Altindag, Ramazan
    FRESENIUS ENVIRONMENTAL BULLETIN, 2021, 30 (11A): : 12588 - 12594
  • [23] State of art of mixed-mode stationary phase
    Xu Jiwei
    Sun Yuanshe
    Tang Tao
    Xia Mingzhu
    Lei Wu
    Wang Fengyun
    Li Tong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (11) : 1140 - 1146
  • [24] Core-Shell Metal-Organic Frameworks as the Mixed-Mode Stationary Phase for Hydrophilic Interaction/Reversed-Phase Chromatography
    Li, Xueyun
    Li, Bo
    Liu, Mingchen
    Zhou, Yufeng
    Zhang, Liyuan
    Qiao, Xiaoqiang
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (10) : 10320 - 10327
  • [25] Imidazolium embedded C8 based stationary phase for simultaneous reversed-phase/hydrophilic interaction mixed-mode chromatography
    Qiao, Xiaoqiang
    Zhang, Lu
    Zhang, Niu
    Wang, Xin
    Qin, Xinying
    Yan, Hongyuan
    Liu, Haiyan
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1400 : 107 - 116
  • [26] The effect of stationary phase on lipophilicity determination of β-blockers using reverse-phase chromatographic systems
    Welerowicz, T
    Buszewski, B
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (10) : 725 - 736
  • [27] Particle packed mixed-mode chromatographic stationary phase for the separation of peptide in liquid chromatography
    Ali, Faiz
    Cheong, Won Jo
    Rafique, Aamra
    AlOthman, Zeid A.
    Sadia, Maria
    Muhammad, Mian
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (07) : 1430 - 1439
  • [28] PREPARATION AND SELECTIVITY CHARACTERISTICS OF FLUOROCARBONACEOUS BONDED STATIONARY PHASE FOR REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KONAKAHARA, T
    OKADA, S
    MONDE, T
    NAKAYAMA, N
    FURUHASHI, J
    SUGAYA, J
    NIPPON KAGAKU KAISHI, 1991, (12) : 1638 - 1646
  • [29] Preparation and chromatographic evaluation of the hydrophilic interaction chromatography stationary phase based on nucleosides or nucleotides
    Tang, Tingfeng
    Guo, Dandan
    Huang, Shaohua
    ANALYTICAL METHODS, 2021, 13 (03) : 419 - 425
  • [30] Preparation and evaluation of a molybdenum disulfide quantum dots embedded C18 mixed-mode chromatographic stationary phase
    Luo, Qiurong
    Ren, Xiujun
    Wei, Siping
    Zheng, Yunchao
    Gao, Die
    Fu, Qifeng
    Xia, Zhining
    Wang, Lujun
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (06) : 1365 - 1374