Accuracy of Blood Glucose Meters for Self-Monitoring Affects Glucose Control and Hypoglycemia Rate in Children and Adolescents with Type 1 Diabetes

被引:15
|
作者
Boettcher, Claudia [1 ]
Dost, Axel [2 ]
Wudy, Stefan A. [1 ]
Flechtner-Mors, Marion [3 ]
Borkenstein, Martin [4 ]
Schiel, Ralf [5 ]
Weitzel, Dieter [6 ]
Bechtold-Dalla Pozza, Susanne [7 ]
Wolf, Johannes [8 ]
Holl, Reinhard W. [3 ]
机构
[1] Univ Giessen, Div Paediat Endocrinol & Diabetol, Ctr Child & Adolescent Med, D-35392 Giessen, Germany
[2] Univ Hosp Jena, Dept Paediat, Jena, Germany
[3] Univ Ulm, Inst Epidemiol & Med Biometry, D-89069 Ulm, Germany
[4] Med Univ Graz, Dept Paediat, Graz, Austria
[5] MEDIGREIF Inselklin Heringsdorf, Dept Diabet & Metab Dis, Ostseebad Heringsdorf, Germany
[6] Childrens & Adolescents Outpatient Ctr, German Clin Diagnost, Wiesbaden, Germany
[7] Univ Munich, Paediat Endocrinol & Diabetol, Munich, Germany
[8] St Vincent Childrens Hosp, Paderborn, Germany
关键词
COGNITIVE FUNCTION; GLYCEMIC CONTROL; SYSTEMS; INSULIN; COMPLICATIONS; MULTICENTER; IMPACT;
D O I
10.1089/dia.2014.0262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims/Hypothesis: This study investigated the accuracy of blood glucose meters for self-monitoring and its influence on glycated hemoglobin (HbA(1c)) levels and the frequency of hypoglycemic coma. Materials and Methods: Self-measured and simultaneously obtained laboratory blood glucose values from 9,163 patients with type 1 diabetes <18 years of age in the German/Austrian Diabetes Prospective Documentation Initiative registry were analyzed by investigating their compliance with the International Organization for Standardization (ISO) criteria (versions 2003 and 2013) and by error grid analyses. Regression models elucidated effects on glucose control and hypoglycemia rates. Results: Depending on the respective subgroup (defined by sex, age, duration of diabetes, mode of insulin therapy), 78.7-94.7% of the self-monitoring of blood glucose (SMBG) values met the old and 79.7-88.6% met the new ISO criteria. In Clarke and Parkes error grid analyses, the percentages of SMBG values in Zone A ranged between 92.8% and 94.6% (Clarke) and between 92.2% and 95.0% (Parkes). The patient group with SMBG devices measuring "far too low" (compared with the laboratory-obtained glucose levels) presented with a higher HbA(1c) level than those measuring "far too high," "too high," "identical/almost identical," or "too low" (based on quintiles of deviation). Performing "far too high" was associated with the highest rate of hypoglycemic coma in comparison with the other deviation quintiles. Conclusions: This study showed that current SMBG devices fulfilled neither the previous nor the new ISO criteria. Large deviations of the SMBG values from the "true" glucose levels resulted in higher HbA(1c) levels and markedly increased rates of hypoglycemic events.
引用
下载
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [41] Improving the effectiveness of self-monitoring of blood glucose in type 2 diabetes
    Holt, Tim A.
    BRITISH JOURNAL OF GENERAL PRACTICE, 2015, 65 (633): : E211 - E212
  • [42] Frequent Self-Monitoring Blood Glucose Correlated to Better Medication Adherence and Glycemic Control in Children with Type 1 Diabetes Mellitus
    Rochmah, Nur
    Soetjipto, Soetjipto
    Faizi, Muhammad
    Hisbiyah, Yuni
    Perwitasari, Rayi Kurnia
    Fedora, Katherine
    Rosyidah, Laili Nur
    Endarko, Endarko
    Kuswanto, Djoko
    Rini, Eka Agustia
    DIABETES METABOLIC SYNDROME AND OBESITY, 2024, 17 : 2203 - 2209
  • [43] The role of intensified blood glucose self-monitoring in predicting long-term hypoglycemia in type 2 diabetes
    Murata, G
    Duckworth, W
    Hoffman, R
    Wendel, CT
    Bokhari, S
    Adam, K
    Solvas, P
    Shah, J
    DIABETES, 2003, 52 : A464 - A464
  • [44] Accuracy of home blood glucose meters during hypoglycemia
    Trajanoski, Z
    Brunner, GA
    Gfrerer, RJ
    Wach, P
    Pieber, TR
    DIABETES CARE, 1996, 19 (12) : 1412 - 1415
  • [45] METERS FOR SELF-MONITORING OF BLOOD-GLUCOSE - PRECISION AND CLINICAL USEFULNESS
    REINAUER, KM
    EHMANN, R
    RENN, W
    LOCHER, M
    EGGSTEIN, M
    MEDIZINISCHE WELT, 1991, 42 (05): : 390 - 396
  • [46] Comparable efficacy of self-monitoring of quantitative urine glucose with self-monitoring of blood glucose on glycaemic control in non-insulin-treated type 2 diabetes
    Lu, J.
    Bu, R. F.
    Sun, Z. L.
    Lu, Q. S.
    Jin, H.
    Wang, Y.
    Wang, S. H.
    Li, L.
    Xie, Z. L.
    Yang, B. Q.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2011, 93 (02) : 179 - 186
  • [47] Intensified self-monitoring of blood glucose (SMBG) improves glycemic control in type 2 diabetes
    Hoffman, R
    Duckworth, W
    Shah, J
    Solvas, P
    Adam, K
    Wendel, C
    Bokhari, S
    Murata, G
    DIABETES, 2003, 52 : A96 - A96
  • [48] Self-monitoring of blood glucose
    Funnell, Martha Mitchell
    DIABETES EDUCATOR, 2007, 33 (06): : 1012 - 1013
  • [49] Self-monitoring of blood glucose in gestational diabetes mellitus
    Fontaine, P
    DIABETES & METABOLISM, 2003, 29 (02) : S37 - S41
  • [50] Consensus Statement on Self-Monitoring of Blood Glucose in Diabetes
    Schnell, O.
    Alawi, H.
    Battelino, T.
    Ceriello, A.
    Diem, P.
    Felton, A.
    Grzeszczak, W.
    Harno, K.
    Kempler, P.
    Satman, I.
    Verges, B.
    DIABETES STOFFWECHSEL UND HERZ, 2009, 18 (04): : 285 - 289