Accuracy of Blood Glucose Meters for Self-Monitoring Affects Glucose Control and Hypoglycemia Rate in Children and Adolescents with Type 1 Diabetes

被引:15
|
作者
Boettcher, Claudia [1 ]
Dost, Axel [2 ]
Wudy, Stefan A. [1 ]
Flechtner-Mors, Marion [3 ]
Borkenstein, Martin [4 ]
Schiel, Ralf [5 ]
Weitzel, Dieter [6 ]
Bechtold-Dalla Pozza, Susanne [7 ]
Wolf, Johannes [8 ]
Holl, Reinhard W. [3 ]
机构
[1] Univ Giessen, Div Paediat Endocrinol & Diabetol, Ctr Child & Adolescent Med, D-35392 Giessen, Germany
[2] Univ Hosp Jena, Dept Paediat, Jena, Germany
[3] Univ Ulm, Inst Epidemiol & Med Biometry, D-89069 Ulm, Germany
[4] Med Univ Graz, Dept Paediat, Graz, Austria
[5] MEDIGREIF Inselklin Heringsdorf, Dept Diabet & Metab Dis, Ostseebad Heringsdorf, Germany
[6] Childrens & Adolescents Outpatient Ctr, German Clin Diagnost, Wiesbaden, Germany
[7] Univ Munich, Paediat Endocrinol & Diabetol, Munich, Germany
[8] St Vincent Childrens Hosp, Paderborn, Germany
关键词
COGNITIVE FUNCTION; GLYCEMIC CONTROL; SYSTEMS; INSULIN; COMPLICATIONS; MULTICENTER; IMPACT;
D O I
10.1089/dia.2014.0262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims/Hypothesis: This study investigated the accuracy of blood glucose meters for self-monitoring and its influence on glycated hemoglobin (HbA(1c)) levels and the frequency of hypoglycemic coma. Materials and Methods: Self-measured and simultaneously obtained laboratory blood glucose values from 9,163 patients with type 1 diabetes <18 years of age in the German/Austrian Diabetes Prospective Documentation Initiative registry were analyzed by investigating their compliance with the International Organization for Standardization (ISO) criteria (versions 2003 and 2013) and by error grid analyses. Regression models elucidated effects on glucose control and hypoglycemia rates. Results: Depending on the respective subgroup (defined by sex, age, duration of diabetes, mode of insulin therapy), 78.7-94.7% of the self-monitoring of blood glucose (SMBG) values met the old and 79.7-88.6% met the new ISO criteria. In Clarke and Parkes error grid analyses, the percentages of SMBG values in Zone A ranged between 92.8% and 94.6% (Clarke) and between 92.2% and 95.0% (Parkes). The patient group with SMBG devices measuring "far too low" (compared with the laboratory-obtained glucose levels) presented with a higher HbA(1c) level than those measuring "far too high," "too high," "identical/almost identical," or "too low" (based on quintiles of deviation). Performing "far too high" was associated with the highest rate of hypoglycemic coma in comparison with the other deviation quintiles. Conclusions: This study showed that current SMBG devices fulfilled neither the previous nor the new ISO criteria. Large deviations of the SMBG values from the "true" glucose levels resulted in higher HbA(1c) levels and markedly increased rates of hypoglycemic events.
引用
下载
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [31] Evaluation of four portable self-monitoring blood glucose meters
    Lippi, Giuseppe
    Salvagno, Gian Luca
    Guidi, Gian Cesare
    Negri, Mauro
    Rizzotti, Paolo
    ANNALS OF CLINICAL BIOCHEMISTRY, 2006, 43 : 408 - 413
  • [32] Self-monitoring of blood glucose in diabetes: is it worth it?
    O'Kane, Maurice J.
    Pickup, John
    ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 : 273 - 282
  • [33] SELF BLOOD GLUCOSE MONITORING UNDERESTIMATES HYPERGLYCEMIA AND HYPOGLYCEMIA AS COMPARED TO CONTINUOUS GLUCOSE MONITORING IN TYPE 1 AND TYPE 2 DIABETES
    Mangrola, Devna
    Cox, Christine
    Furman, Arianne S.
    Krishnan, Sridevi
    Karakas, Sidika E.
    ENDOCRINE PRACTICE, 2018, 24 (01) : 47 - 52
  • [34] Self-monitoring of blood glucose in children, adolescents, and young adults in the community
    Lecaire, T
    Daniels, K
    Allen, C
    Palta, M
    D'Alessio, D
    DIABETES, 1998, 47 : A155 - A155
  • [35] The effect of self-monitoring of blood glucose on metabolic control in type 2 diabetes patients
    Czupryniak, L.
    Szymanska-Garbacz, E.
    Saryusz-Wolska, M.
    Pawlowski, M.
    Sojczynska, J.
    Wojcik-Odyniec, J.
    Jakubczyk, E.
    Szymborska-Kajanek, A.
    Wrobel, M.
    Ruprecht, Z.
    Majcher-Witczak, G.
    Trojak, A.
    Malecki, M. T.
    Loba, J.
    Strojek, K.
    DIABETOLOGIA, 2011, 54 : S32 - S33
  • [36] Comparative Analysis of the Efficacy and Safety of Continuous Glucose Monitoring and Self-Monitoring Blood Glucose in Type 1 Diabetes Mellitus
    Floyd, Baraka D.
    Chandra, Prakash
    Hall, Stephanie P.
    Phillips, Christopher O.
    Alema-Mensah, Ernest
    Strayhorn, Gregory
    Ofili, Elizabeth
    Umpierrez, Guillermo
    DIABETES, 2010, 59 : A33 - A33
  • [37] Randomized comparison of the metabolic effect of continuous glucose monitoring system (CGMS) and self-monitoring blood glucose (SMBG) in children with type 1 diabetes
    Deiss, DA
    Hartmann, R
    Schmidt, J
    Kordonouri, O
    DIABETES, 2004, 53 : A460 - A461
  • [38] Self-monitoring of blood glucose experiences of adults with type 2 diabetes
    Dlugasch, Lucie B.
    Ugarriza, Doris N.
    JOURNAL OF THE AMERICAN ASSOCIATION OF NURSE PRACTITIONERS, 2014, 26 (06) : 323 - 329
  • [39] Self-monitoring of blood glucose in type 2 diabetes: systematic review
    Clar, C.
    Barnard, K.
    Cummins, E.
    Royle, P.
    Waugh, N.
    HEALTH TECHNOLOGY ASSESSMENT, 2010, 14 (12) : 1 - +
  • [40] Accuracy of devices used for self-monitoring of blood glucose
    Johnson, RN
    Baker, JR
    ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 68 - 74