Background: Rotating hinge knee prostheses (with or without distal femoral replacement) are indicated in cases of unreconstructible bony or soft tissue compromise. Despite their versatility, these implants have demonstrated high rates of mechanical failure. We aimed to review clinical outcomes of a novel hinged knee arthroplasty system. Methods: We reviewed all cases in a prospective database of hinged total knee arthroplasty (with and without distal femoral arthroplasty) involving a single manufacturer's implant system at a large tertiary-level academic health sciences center. We collected reasons for surgery, implant survivorship, reasons for revision, and clinical outcomes (Short Form 12, Western Ontario and McMaster Universities Osteoarthritis Index, and Knee Society Scores). Results: Seventy-six cases of hinged knee implants using the knee system under investigation were performed (39 hinged total knee and 37 distal femoral replacements) between 2011 and 2018, inclusive. Indications for surgery varied, with second-stage reimplantation most common for rotating hinge and fracture most common for distal femoral arthroplasty. There were 6 revisions in the rotating hinge group (none for aseptic loosening) and 5 in the distal femoral arthroplasty group (1 for aseptic loosening). Average follow-up was 2.89 +/- 2.09 years. Postoperative Short Form 12 (Physical Component), Western Ontario and McMaster Universities Osteoarthritis Index, and Knee Society Scores were 30.12 +/- 10.17, 55.90 +/- 21.51, and 115.62 +/- 45.20, respectively. Conclusion: This novel hinged knee system is a highly durable option for complex and revision knee arthroplasty. Early failures tend to be secondary to infection. We observed only a single case of aseptic loosening. Although these early results are encouraging, ongoing follow-up is required to determine long-term prognosis in patients receiving this implant. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:1323 / 1327
页数:5
相关论文
共 50 条
  • [21] Total knee arthroplasty with modular rotating-platform hinge
    Jones, Richard E.
    [J]. ORTHOPEDICS, 2006, 29 (09) : S80 - S82
  • [22] Rotating hinge total knee arthroplasty in severely affected knees
    Westrich, GH
    Mollano, AV
    Sculco, TP
    Buly, RL
    Laskin, RS
    Windsor, R
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (379) : 195 - 208
  • [23] Use of the rotating hinge for salvage of the infected total knee arthroplasty
    Berman, AT
    OBrien, JT
    Israelite, C
    [J]. ORTHOPEDICS, 1996, 19 (01) : 73 - 76
  • [24] ROTATING HINGE REVISION TOTAL KNEE ARTHROPLASTY FOR SEVERE ARTHROFIBROSIS
    Debbi, Eytan M.
    Alpaugh, Kyle
    Driscoll, Daniel A.
    Tarity, T. David
    Gkiatas, Ioannis
    Sculco, Peter K.
    [J]. JBJS ESSENTIAL SURGICAL TECHNIQUES, 2021, 11 (04):
  • [25] The role of rotating hinge implants in revision total knee arthroplasty
    Pasquier, Gilles
    Ehlinger, Matthieu
    Mainard, Didier
    [J]. EFORT OPEN REVIEWS, 2019, 4 (06): : 269 - 278
  • [26] Rotating-hinge total knee arthroplasty in a patient with genu recurvatum after osteomyelitis of the distal femur
    Nishitani, Kohei
    Nakagawa, Yasuaki
    Suzuki, Takashi
    Koike, Kazuhiro
    Nakamura, Takashi
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (04): : 630 - 633
  • [27] Increased constraint of rotating hinge knee prosthesis is associated with poorer clinical outcomes as compared to constrained condylar knee prosthesis in total knee arthroplasty
    Lim, Jason Beng Teck
    Pang, Hee Nee
    Tay, Keng Jin Darren
    Chia, Shi-lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (03): : 529 - 535
  • [28] Increased constraint of rotating hinge knee prosthesis is associated with poorer clinical outcomes as compared to constrained condylar knee prosthesis in total knee arthroplasty
    Jason Beng Teck Lim
    Hee Nee Pang
    Keng Jin Darren Tay
    Shi-lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 529 - 535
  • [29] Survivorship, clinical outcomes and indications for revision in uncemented unicompartmental knee arthroplasty: systematic review
    Puvanendran, A.
    Jaibaji, M.
    Volpin, A.
    Konan, S.
    [J]. ACTA ORTHOPAEDICA BELGICA, 2023, 89 (01): : 83 - 95
  • [30] Clinical outcomes of primary rotating-hinge knee arthroplasty for knees with severe deformity
    Zhang Fujiang
    Liu Yabin
    Xiao Yu
    Liu Wenbin
    [J]. CHINESE MEDICAL JOURNAL, 2014, 127 (09) : 1791 - 1793