Increased constraint of rotating hinge knee prosthesis is associated with poorer clinical outcomes as compared to constrained condylar knee prosthesis in total knee arthroplasty

被引:0
|
作者
Jason Beng Teck Lim
Hee Nee Pang
Keng Jin Darren Tay
Shi-lu Chia
Ngai Nung Lo
Seng Jin Yeo
机构
[1] Singapore General Hospital,Department of Orthopaedic Surgery
[2] Singapore General Hospital,Department of Orthopaedic Surgery
关键词
Rotating hinge knee; Constrained condylar knee; Revision total knee arthroplasty; Outcomes; Complications;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate whether there are any differences in patient-reported outcome measures between semi-constrained condylar constrained knee (CCK) and fully constrained rotating hinge knee (RHK) prostheses in midterm follow-up. We reviewed prospectively collected data of our hospital arthroplasty registry between 2007 and 2014. Thirty-nine patients were identified to have RHK prosthesis TKA and matched for a number of primary/revision TKA, gender, age, body mass index and pre-operative clinical scores to a control group of 78 patients with CCK TKA. Patient demographics, range of movement, varus/valgus deformity, Short Form 36 (SF-36) scores, Oxford Knee Score (OKS), Knee Society Score (KSS) and patient satisfaction were evaluated. Pre-operatively, the RHK and the control group of CCK had similar demographics, proportion of primary/revision TKA and baseline clinical scores (p > 0.05). At 2-year follow-up, patients with CCK prostheses had significantly better clinical outcomes as compared to patients with RHK prosthesis in terms of KSS functional scores, OKS, SF-36 sub-domains of physical functioning, physical role functioning and physical component score. We conclude that at midterm follow-up of 2 years, the CCK patients as compared to RHK patients reported better clinical and functional outcomes in terms of OKS, KSS functional score and SF-36 with a greater proportion of patients who were satisfied and had their expectations met by surgery. Further biomechanical studies are needed to investigate the association between component constraint and clinical outcomes for these prostheses.
引用
收藏
页码:529 / 535
页数:6
相关论文
共 50 条
  • [1] Increased constraint of rotating hinge knee prosthesis is associated with poorer clinical outcomes as compared to constrained condylar knee prosthesis in total knee arthroplasty
    Lim, Jason Beng Teck
    Pang, Hee Nee
    Tay, Keng Jin Darren
    Chia, Shi-lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (03): : 529 - 535
  • [2] Similar outcomes of constrained condylar knee and rotating hinge prosthesis in revision surgery for extension instability after primary total knee arthroplasty
    Miralles-Munoz, Francisco A.
    Pineda-Salazar, Manuel
    Rubio-Morales, Marta
    Gonzalez-Parreno, Santiago
    Ruiz-Lozano, Matias
    Lizaur-Utrilla, Alejandro
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (08)
  • [3] Condylar constrained knee prosthesis and rotating hinge prosthesis for revision total knee arthroplasty for mechanical failure have not the same indications and same results
    Barnoud, William
    Schmidt, Axel
    Swan, John
    Sappey-Marinier, Elliot
    Batailler, Cecile
    Servien, Elvire
    Lustig, Sebastien
    [J]. SICOT-J, 2021, 7
  • [4] Revision Total Knee Arthroplasty with Use of a Constrained Condylar Knee Prosthesis
    Kim, Young-Hoo
    Kim, Jun-Shik
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06): : 1440 - 1447
  • [5] REVISION TOTAL KNEE ARTHROPLASTY USING THE MODERN CONSTRAINED CONDYLAR KNEE PROSTHESIS
    Nakano, Naoki
    Matsumoto, Tomoyuki
    Muratsu, Hirotsugu
    Ishida, Kazunari
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    [J]. ACTA ORTOPEDICA BRASILEIRA, 2016, 24 (06): : 304 - 308
  • [6] TOTAL KNEE ARTHROPLASTY USING THE KINEMATIC ROTATING HINGE PROSTHESIS
    SHAW, JA
    BALCOM, W
    GREER, RB
    [J]. ORTHOPEDICS, 1989, 12 (05) : 647 - 654
  • [7] Long-Term Clinical Outcomes and Survivorship of Revision Total Knee Arthroplasty with Use of a Constrained Condylar Knee Prosthesis
    Kim, Young-Hoo
    Park, Jang-Won
    Kim, Jun-Shik
    Oh, Hyun-Keun
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (10): : 1804 - 1809
  • [8] Rotating hinge knee versus constrained condylar knee in revision total knee arthroplasty: A meta-analysis
    Yoon, Jung-Ro
    Cheong, Ji-Young
    Im, Jung-Taek
    Park, Phil-Sun
    Park, Jae-Ok
    Shin, Young-Soo
    [J]. PLOS ONE, 2019, 14 (03):
  • [9] Constraint in complex primary total knee arthroplasty: rotating hinge versus condylar constrained implants
    Francesco Castagnini
    Barbara Bordini
    Monica Cosentino
    Cristina Ancarani
    Stefano Lucchini
    Giovanni Bracci
    Francesco Traina
    [J]. Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 3965 - 3973
  • [10] The Kinematic Rotating Hinge prosthesis for complex knee arthroplasty
    Springer, BD
    Hanssen, AD
    Sim, FH
    Lewallen, DG
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 283 - 291