Design of a compact corneal topographer to characterize the shape of the cornea

被引:0
|
作者
Campos-Garcia, Manuel [1 ]
Aguirre-Aguirre, Daniel [1 ]
Salvador Perez-Lomeli, Juan [1 ]
Pena-Conzuelo, Andres [1 ]
Huerta-Carranza, Oliver [1 ]
Camargo-Fierro, Christian [2 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Ciencias Aplicadas & Tecnol, Circuito Exterior S-N,Ciudad Univ, Mexico City 04510, DF, Mexico
[2] Inst Politecn Nacl, Escuela Super Med, Calle Plan San Luis Diaz Miron S-N, Mexico City 11340, DF, Mexico
基金
芬兰科学院;
关键词
Null-screen; Corneal Topography; Aspherics; Surface Measurements; Optical Metrology; NULL-SCREEN;
D O I
10.1117/12.2556052
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work we report the design of a conical corneal null-screen compact topographer, which uses a mobile device to capture null-screen reflection produced by the posterior corneal surface. The instrument features a head holder like those of virtual reality headset with the aim of align the topographer. For corneal topography the device is calibrated by testing a reference surface where the geometrical parameters such as the radius of curvature and the conic constant, are obtained. We present examples of surface topography measurements on some human corneas.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] SHAPE OF THE CORNEA AND CONJUNCTIVA
    WICHTERLE, K
    VODNANSKY, J
    WICHTERLE, O
    OPTOMETRY AND VISION SCIENCE, 1991, 68 (03) : 232 - 235
  • [42] Effect of the skew ray error on corneal topography using a cone topographer
    Huerta-Carranza, Oliver
    Campos-Garcia, Manuel
    Pantoja-Arredondo, Luis Angel
    Granados-Agustin, Fermin Salomon
    OPTICAL FABRICATION AND TESTING VIII, 2024, 13021
  • [43] Repeatability of Internal Aberrometry with a New Simultaneous Capture Aberrometer/Corneal Topographer
    Gifford, Paul
    Swarbrick, Helen A.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (06) : 929 - 938
  • [44] Cornea shape and accommodation
    Popiolek-Masajada, A
    Pierscionek, BK
    Kasprzak, H
    12TH CZECH-SLOVAK-POLISH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2001, 4356 : 364 - 366
  • [45] Modeling the conical corneal null-screen topographer with the Fermat principle
    Pena-Conzuelo, Andres
    Campos-Garcia, Manuel
    OPTICS AND PHOTONICS FOR ADVANCED DIMENSIONAL METROLOGY, 2021, 11352
  • [46] Assessment of the Impact of Saccade on Corneal Topography Using Video-Topographer
    Yang, Zhenghao
    Yokoi, Norihiko
    Georgiev, Georgi Asenov
    Niu, Mengxi
    Kato, Hiroaki
    Koizumi, Noriko
    Kinoshita, Shigeru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [47] Contact lens-induced corneal swelling and surface changes measured with the Orbscan II corneal topographer
    Moezzi, AM
    Fonn, D
    Simpson, TL
    Sorbara, L
    OPTOMETRY AND VISION SCIENCE, 2004, 81 (03) : 189 - 193
  • [48] Corneal Shape, Volume, and Interocular Symmetry: Parameters to Optimize the Design of Biosynthetic Corneal Substitutes
    Durr, Georges M.
    Auvinet, Edouard
    Ong, Jeb
    Meunier, Jean
    Brunette, Isabelle
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (08) : 4275 - 4282
  • [49] Accuracy and sensitivity analysis of the conical null-screen based corneal topographer
    Cossio-Guerrero, Cesar
    Campos-Garcia, Manuel
    CURRENT DEVELOPMENTS IN LENS DESIGN AND OPTICAL ENGINEERING XVII, 2016, 9947
  • [50] A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes
    Ferreira, Tiago B.
    Ribeiro, Filomena J.
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 1521 - 1529