Design of a compact corneal topographer to characterize the shape of the cornea

被引:0
|
作者
Campos-Garcia, Manuel [1 ]
Aguirre-Aguirre, Daniel [1 ]
Salvador Perez-Lomeli, Juan [1 ]
Pena-Conzuelo, Andres [1 ]
Huerta-Carranza, Oliver [1 ]
Camargo-Fierro, Christian [2 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Ciencias Aplicadas & Tecnol, Circuito Exterior S-N,Ciudad Univ, Mexico City 04510, DF, Mexico
[2] Inst Politecn Nacl, Escuela Super Med, Calle Plan San Luis Diaz Miron S-N, Mexico City 11340, DF, Mexico
基金
芬兰科学院;
关键词
Null-screen; Corneal Topography; Aspherics; Surface Measurements; Optical Metrology; NULL-SCREEN;
D O I
10.1117/12.2556052
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work we report the design of a conical corneal null-screen compact topographer, which uses a mobile device to capture null-screen reflection produced by the posterior corneal surface. The instrument features a head holder like those of virtual reality headset with the aim of align the topographer. For corneal topography the device is calibrated by testing a reference surface where the geometrical parameters such as the radius of curvature and the conic constant, are obtained. We present examples of surface topography measurements on some human corneas.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Precision of Corneal Aberrations Measured by a New SD-OCT/Placido Topographer and Its Agreement With a Scheimpflug/Placido Topographer
    Ning, Rui
    Niu, Lingling
    Xing, Wenqian
    Wan, Ting
    Huang, Xiaomin
    Xiahou, Jinxuan
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Wang, Xiaoying
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (06) : 405 - +
  • [32] CORNEAL TRANSPLANTATION AND THE ARTIFICIAL CORNEA
    Albon, Julie
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2003, 3 (01) : 95 - 106
  • [33] Clinical applications of the OPD-Scan wavefront aberrometer/corneal topographer
    Buscemi, P
    JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (03) : S385 - S388
  • [34] Topographer reconstruction of the nonrotation-symmetric anterior corneal surface features
    Sicam, Victor Arni D. P.
    Van der Heijde, Rob G. L.
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (12) : 910 - 918
  • [35] Comparison of Accuracy of Intraocular Lens Calculations Using Automated Keratometry, a Placido-Based Corneal Topographer, and a Combined Placido-Based and Dual Scheimpflug Corneal Topographer
    Shirayama, Mariko
    Wang, Li
    Koch, Douglas D.
    Weikert, Mitchell P.
    CORNEA, 2010, 29 (10) : 1136 - 1138
  • [36] Specular surface reconstruction for multi-camera corneal topographer arrangements
    Fazekas, Zoltan
    Soumelidis, Alexandros
    Bodis-Szomoru, Andras
    Schipp, Ferenc
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2254 - +
  • [37] Repeatability and comparability of corneal power and corneal astigmatism obtained from a point-source color light-emitting diode topographer, a Placido-based corneal topographer, and a low-coherence reflectometer
    Ventura, Bruna V.
    Al-Mohtaseb, Zaina
    Wang, Li
    Koch, Douglas D.
    Weikert, Mitchell P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2242 - 2250
  • [38] Evaluation of the performance of the posterior edge tracker of the Orbscan II corneal topographer
    Roberts, CJ
    Mahmoud, A
    Castellano, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U2 - U2
  • [39] Comparative Analysis of Some Modal Reconstruction Methods of the Shape of the Cornea from Corneal Elevation Data
    Martinez-Finkelshtein, Andrei
    Delgado, Antonia M.
    Castro, Gracia M.
    Zarzo, Alejandro
    Alio, Jorge L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (12) : 5639 - 5645
  • [40] The impact of the posterior corneal surface shape on the wavefront aberrations of the cornea following refractive surgery.
    Munger, R