Liquid chromatography-electron ionization mass spectrometry: Fields of application and evaluation of the performance of a Direct-EI interface

被引:23
|
作者
Cappiello, A [1 ]
Famiglini, G [1 ]
Palma, P [1 ]
Siviero, A [1 ]
机构
[1] Univ Urbino, Ist Sci Chim F Bruner, I-61029 Urbino, Italy
关键词
nano-column liquid chromatography; electron ionization mass spectrometry; Direct-EI; trace analysis;
D O I
10.1002/mas.20054
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A comprehensive evaluation and a thorough discussion of the fields of possible applications of the Direct-EI interface are described in this review. Direct-EI allows the direct introduction of the effluent from a capillary HPLC column into the electron ionization (EI) ion source of a mass spectrometer Thanks to the reduced liquid intake and an in-source nebulizer the interfacing process occurs smoothly and entirely into the ion source. No intermediate interfacing mechanisms of any sort are interposed between the column and the mass spectrometer, thus circumventing any undesired sample loss and minimizing the effort for instrument modification. Theoretically, any GC-MS system can be converted into an LC-MS for EI amenable compounds. Several parameters, crucial for a successful integration of liquid chromatography and mass spectrometry, have been considered in the evaluation of the functioning of such an interface: limit of detection, linearity of response, reproducibility, and chromatographic compatibility. Different mobile phases, also containing non-volatile buffers, were taken into account, demonstrating an outstanding separation flexibility. The entire set of experiments was carried out at different flow rates and temperatures of the ion source. The interface behavior was also tested in real world applications, with mixtures of pesticides, hormones, nitro-PAH, and endocrine-disrupting compounds, allowing picogram level detection and the possibility to record library-matchable, readily interpretable electron ionization mass spectra, for prompt compound characterization and confirmation. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:978 / 989
页数:12
相关论文
共 50 条
  • [31] Sonic spray ionization interface for liquid chromatography-mass spectrometry
    Björkman, HT
    Edlund, PO
    Jacobsson, SP
    ANALYTICA CHIMICA ACTA, 2002, 468 (02) : 263 - 274
  • [32] New Ionization Technology for Interface of Liquid Chromatography-Mass Spectrometry
    Tian, Tian
    Zhang, Fang
    Zhang, Shusheng
    Feng, Chenguo
    Su, Yue
    Lin, Guoqiang
    PROGRESS IN CHEMISTRY, 2020, 32 (05) : 604 - 616
  • [33] Characterization of anthocyanin from red sorghum (Sorghum bicolor) bran by liquid chromatography-electron spray ionization mass spectrometry analysis
    Suganyadevi, P.
    Saravanakumar, M.
    Mohandas, S.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2021, 27 (2-4) : 107 - 114
  • [34] Direct coupling of ionic high-performance liquid chromatography with electrospray ionization mass spectrometry utilizing a microdialysis junction interface
    Liu, CL
    Verma, SS
    JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) : 93 - 104
  • [35] Performance liquid chromatography and liquid-chromatography-ejectrospray ionization-mass spectrometry
    Liu, SM
    Chen, KS
    Schiemann, W
    Strack, D
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (08) : 1023 - 1023
  • [36] Identification of a Radical Formed in the Reaction Mixtures of Ram Seminal Vesicle Microsomes with Arachidonic Acid Using High Performance Liquid Chromatography-Electron Spin Resonance Spectrometry and High Performance Liquid Chromatography-Electron Spin Resonance-Mass Spectrometry
    Minakata, Katsuyuki
    Iwahashi, Hideo
    JOURNAL OF CLINICAL BIOCHEMISTRY AND NUTRITION, 2010, 46 (02) : 135 - 139
  • [37] Determination of the propylene oxide-hemoglobin adduct by gas chromatography-electron impact ionization mass spectrometry
    Shin, Ho-Sang
    Ahn, Hye-Sil
    JOURNAL OF MASS SPECTROMETRY, 2006, 41 (06): : 802 - 809
  • [38] Improving quantitative gas chromatography-electron ionization mass spectrometry results using a modified ion source: Demonstration for a pharmaceutical application
    D'Autry, Ward
    Wolfs, Kris
    Hoogmartens, Jos
    Adams, Erwin
    Van Schepdael, Ann
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (26) : 4034 - 4038
  • [39] ANALYSIS OF STEROL ESTERS BY CAPILLARY GAS CHROMATOGRAPHY-ELECTRON IMPACT AND CHEMICAL IONIZATION-MASS SPECTROMETRY
    LUSBY, WR
    THOMPSON, MJ
    KOCHANSKY, J
    LIPIDS, 1984, 19 (11) : 888 - 901
  • [40] Nano-liquid chromatography-direct electron ionization mass spectrometry: improving performance by a new ion source adapter
    Flender, Cornelia
    Wolf, Christian
    Leonhard, Peter
    Karas, Michael
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (10): : 1004 - 1010