An improved shielded RF transmit coil for low-frequency NMR and MRI

被引:4
|
作者
Kuzmin, V. V. [1 ]
Bidinosti, C. P. [2 ]
Hayden, M. E. [3 ]
Nacher, P. -J. [1 ]
机构
[1] UPMC Sorbonne Univ, Coll France, ENS PSL Res Univ, Lab Kastler Brossel,CNRS, F-75005 Paris, France
[2] Univ Winnipeg, Dept Phys, Winnipeg, MB R3B 2E9, Canada
[3] Simon Fraser Univ, Dept Phys, Burnaby, BC V5A 1S6, Canada
关键词
RF coils; NMR; MRI;
D O I
10.1016/j.jmr.2015.05.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe an actively shielded cylindrical RF transmit coil producing a highly uniform internal field (+/- 0.5%) over an extended volume and a strongly suppressed (divided by 20) external field. Direct field mapping and experimental checks using in-situ NMR and MRI of polarised He-3 at low temperature demonstrate performance consistent with numerical field computations. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 50 条
  • [31] Comprehensive analysis of transmit performance for an 8-element loop MRI RF coil at 300 MHz
    Kozlov, M.
    Turner, R.
    40TH EUROPEAN MICROWAVE CONFERENCE, 2010, : 328 - 331
  • [32] Shielding of low-frequency magnetic interference in weak-field MRI by a single-layer cylindrical coil
    Planinsic, G
    JOURNAL OF MAGNETIC RESONANCE, 1997, 126 (01) : 30 - 38
  • [33] IMPROVED LOW-FREQUENCY CURRENT-AMPLIFIERS
    NEDUNGADI, A
    PROCEEDINGS OF THE IEEE, 1979, 67 (11) : 1569 - 1570
  • [34] IMPROVED LOW-FREQUENCY STABILITY OF BOLOMETRIC DETECTORS
    WILBANKS, T
    DEVLIN, M
    LANGE, AE
    SATO, S
    BEEMAN, JW
    HALLER, EE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 566 - 572
  • [35] RESULTS FROM IMPROVED LOW-FREQUENCY ACCELEROMETRY
    DRATLER, J
    BLOCK, B
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1971, 52 (04): : 285 - &
  • [36] FEA simulations for low-frequency multi-layer magnetically shielded rooms
    Yang, Songnan
    Zhang, Xiaohui
    Gao, Jiuxiang
    Liu, Yuanyuan
    Zhang, Jinsheng
    Xi, Xiaoli
    AIP ADVANCES, 2022, 12 (08)
  • [37] Low-frequency NMR with a non-resonant circuit
    Hopper, Timothy
    Mandal, Soumyajit
    Cory, David
    Huerlimann, Martin
    Song, Yi-Qiao
    JOURNAL OF MAGNETIC RESONANCE, 2011, 210 (01) : 69 - 74
  • [38] ADJUSTABLE PHASE DEVICE FOR LOW-FREQUENCY NMR EXPERIMENTS
    WEYAND, K
    SIMON, E
    LEUCHTER, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1979, 50 (12): : 1521 - 1526
  • [39] Comprehensive analysis of transmit performance for an 8-element loop MRI RF transceiver coil at 300 MHz
    Kozlov, Mikhail
    Xue, Rong
    Turner, Robert
    2012 ASIA-PACIFIC MICROWAVE CONFERENCE (APMC 2012), 2012, : 1064 - 1066
  • [40] Source of low-frequency fluctuations in functional MRI signal
    Razavi, Mehrdad
    Eaton, Brent
    Paradiso, Sergio
    Mina, Mani
    Hudetz, Anthony G.
    Bolinger, Lizann
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 891 - 897