Comprehensive analysis of transmit performance for an 8-element loop MRI RF transceiver coil at 300 MHz

被引:0
|
作者
Kozlov, Mikhail [1 ]
Xue, Rong
Turner, Robert [1 ]
机构
[1] Max Planck Inst Human Cognit & Brain Sci, D-04103 Leipzig, Germany
关键词
Antenna arrays; Biomedical imaging; Computational electromagnetics;
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
We numerically investigated the performance of an 8-channel loop-based MRI RF transceiver coil of length 200 mm at 300 MHz. The transceiver was loaded by three human head models placed at five axial positions. For each position and size of the model a set of tune capacitors was obtained, and the robustness and safety of near field generation was evaluated. The transceiver coil showed high robustness, although the safety supervision factor needed to be adjusted for each head position. An optimal head position could be found that did not require transceiver retuning. In this position, a possible reduction of both transmit RF magnetic field and safety excitation efficiency needs to be monitored.
引用
收藏
页码:1064 / 1066
页数:3
相关论文
共 12 条
  • [1] Comprehensive analysis of transmit performance for an 8-element loop MRI RF coil at 300 MHz
    Kozlov, M.
    Turner, R.
    40TH EUROPEAN MICROWAVE CONFERENCE, 2010, : 328 - 331
  • [2] Analysis of RF transmit performance for a multi-row multi-channel MRI loop array at 300 and 400 MHz
    Kozlov, Mikhail
    Turner, Robert
    ASIA-PACIFIC MICROWAVE CONFERENCE 2011, 2011, : 1190 - 1193
  • [3] RF transmit robustness of dual-row MRI array at 300 MHz
    Kozlov, Mikhail
    Turner, Robert
    2013 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC 2013), 2013, : 551 - 553
  • [4] Influence of a Dielectric Insert of High Permittivity on the Transmit Performance of a 300 MHz Multi-channel MRI Loop Array
    Kozlov, M.
    Turner, R.
    PIERS 2011 MARRAKESH: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2011, : 116 - 120
  • [5] Towards Ultra-Low RF Power Simultaneous Transmit and Receive (STAR) MRI with a Wearable RF Transceiver Head Coil
    Colwell, Zachary A.
    Kandala, Sri Kirthi
    DelaBarre, Lance
    Idiyatullin, Djaudat
    Adriany, Gregor
    Garwood, Michael
    Vaughan, John Thomas
    Sohn, Sung-Min
    2024 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM, IMS 2024, 2024, : 1008 - 1011
  • [6] Analysis of RF transmit performance for a 7T dual row multichannel MRI loop array
    Kozlov, Mikhail
    Turner, Robert
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 547 - 553
  • [7] Robustness of 300MHz 8-channel dual-row transmit arrays for MRI
    Kozlov, M.
    Moeller, H. E.
    2015 IEEE INTERNATIONAL CONFERENCE ON MICROWAVES, COMMUNICATIONS, ANTENNAS AND ELECTRONIC SYSTEMS (COMCAS), 2015,
  • [8] Influence of the Position of Decoupling Capacitors on RF Transmit Performance for a 7 T MRI Loop Array
    Kozlov, M.
    Turner, R.
    PROCEEDINGS OF PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2012), 2012, : 1323 - 1327
  • [9] Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz
    Collins, CM
    Yang, QX
    Wang, JH
    Zhang, X
    Liu, H
    Michaeli, S
    Zhu, XH
    Adriany, G
    Vaughan, JT
    Anderson, P
    Merkle, H
    Ugurbil, K
    Smith, MB
    Chen, W
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) : 1026 - 1028
  • [10] Influence of Shield Distance on RF Transmit Performance for a 7T Multi-channel MRI Loop Array
    Kozlov, M.
    Turner, R.
    PROCEEDINGS OF PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2012), 2012, : 255 - 259