Microsensor for Cell Force Measurement

被引:1
|
作者
Swieszkowski, Wojciech [1 ]
Smolik, Waldemar T. [1 ]
Danz, Norbert [2 ]
Forester, Erik [2 ]
Kaiser, Jean-Pierre [3 ]
Bruinink, Arie [3 ]
Kurzydlowski, Krzysztof J. [1 ]
机构
[1] Warsaw Univ Technol, PL-02507 Warsaw, Poland
[2] Fraunhofer Inst Appl Opt & Precis Engn, D-07745 Jena, Germany
[3] Swiss Fed Labs Mat Testing & Res, Empa, CH-9014 St Gallen, Switzerland
关键词
Cell Forces; Cell Motility; Cell Imaging; Micro-Patterned Substrate; Micropost Array; TRACTION FORCES;
D O I
10.1166/sl.2010.1339
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cell elasticity, motility and migration are very important for understanding various biological processes. Currently, monitoring cellular traction forces is desired as new marker to monitor cell functionality. We developed a sensor system for cell force measurement based upon a polymer microchip covered with a micropillar matrix. The spring constant is chosen to enable pillar bending by cellular forces. The microchip is read out optically. Besides a transmission image to analyze pillar bending, two different fluorescence images of dye markers can be taken sequentially. Matrix with the cells is illuminated by spatially homogenized LED radiation. The focal position during long term experiments can be maintained by means of a piezo stage in order to obtain highly resolved images from the CCD imager. Sophisticated software controls the optical system and performs image registration. First, one transmission (red) as well as two fluorescence images (blue & green) are taken using appropriate CCD gain and integration times. Fluorescence information yields those pillar positions that are at least covered by a cell. The transmission image is used to calculate the magnitude and direction of pillars deflection. Therefore, detection of single pillar position and its deviation from a hexagonal grid is analyzed automatically, enabling a mapping of traction forces. The system containing transducer polymer chip, optics, and dedicated software analysis is a complete imaging system for image registration, single cell visualization and cellular force measurement. First results of cellular force measurements obtained are presented.
引用
收藏
页码:736 / 743
页数:8
相关论文
共 50 条
  • [41] Measurement of cell traction force with a thin film PDMS cantilever
    Holley, Merrel T.
    YekrangSafakar, Ashkan
    Maziveyi, Mazvita
    Alahari, Suresh K.
    Park, Kidong
    [J]. BIOMEDICAL MICRODEVICES, 2017, 19 (04)
  • [42] Measurement of cell traction force with a thin film PDMS cantilever
    Merrel T. Holley
    Ashkan YekrangSafakar
    Mazvita Maziveyi
    Suresh K. Alahari
    Kidong Park
    [J]. Biomedical Microdevices, 2017, 19
  • [43] PLASMONIC MICROPILLARS FOR MASSIVELY PARALLEL PRECISION CELL FORCE MEASUREMENT
    Xiao, Fan
    Wen, Ximiao
    Chiou, Pei-Yu
    [J]. 30TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2017), 2017, : 243 - 246
  • [44] Microsensor Device for Minimally Invasive Measurement of Moisture Storage in Plants Shoots
    Ino, Fumiya
    Ishida, Kazuma
    Terao, Kyohei
    Takao, Hidekuni
    Shimokawa, Fusao
    [J]. 2020 IEEE SENSORS, 2020,
  • [45] On the modeling of a piezoelectrically actuated microsensor for simultaneous measurement of fluids viscosity and density
    Rezazadeh, Ghader
    Ghanbari, Mina
    Mirzaee, Iraj
    Keyvani, Aliasghar
    [J]. MEASUREMENT, 2010, 43 (10) : 1516 - 1524
  • [46] EARLY DETECTION OF CELL-METABOLISM WITH A SILICON MICROSENSOR
    MARTINOIA, S
    MELONI, M
    PARODI, MT
    TEDESCO, M
    CICCARELLI, C
    GRATTAROLA, M
    [J]. CYTOTECHNOLOGY, 1993, 11 : 86 - 88
  • [47] Thin Layer Ammonia Microsensor Chip and System for Measurement of Ammonia Nitrogen
    Bian He-Ming
    Bian Chao
    Tong Jian-Hua
    Sun Ji-Zhou
    Zhang Hong
    Han Jing-Hong
    Xia Shan-Hong
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (02) : 196 - 200
  • [48] Interferometric measurement using bimorph actuated staggered mirror (BASM) microsensor
    Lim, Si-Hyung
    Yim, Hong Jae
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2008, 22 (04) : 740 - 745
  • [49] Ag/polypyrrole composites for polarizable dry microsensor used in bioimpedance measurement
    Telipan, G.
    Pislaru-Danescu, L.
    Ion, I.
    Marinescu, V
    [J]. CAS 2020 PROCEEDINGS: 2020 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 2020, : 23 - 26
  • [50] Interferometric measurement using bimorph actuated staggered mirror (BASM) microsensor
    Si-Hyung Lim
    Hong Jae Yim
    [J]. Journal of Mechanical Science and Technology, 2008, 22