Real-time sonoelastography using an external reference material: test-retest reliability of healthy Achilles tendons

被引:17
|
作者
Schneebeli, Alessandro [1 ]
Del Grande, Filippo [2 ]
Vincenzo, Gabriele [2 ]
Cescon, Corrado [1 ]
Clijsen, Ron [3 ,4 ,5 ]
Biordi, Fulvio [6 ]
Barbero, Marco [1 ]
机构
[1] Univ Appl Sci & Arts Southern Switzerland, Dept Business Econ Hlth & Social Care, Rehabil Res Lab 2rLab, Manno, Switzerland
[2] EOC, Osped Reg Lugano, Serv Radiol, Lugano, Switzerland
[3] Univ Appl Sci & Arts Southern Switzerland, Dept Business Econ Hlth & Social Care, Landquart, Switzerland
[4] Univ Coll Physiotherapy, Thim van der Laan AG, Landquart, Switzerland
[5] Vrije Univ Brussel, Fac Phys Educ & Phys Therapy, Brussels, Belgium
[6] ESAOTE SpA, Genoa, Italy
关键词
Sonoelastography; Achilles tendon; Reliability; SHEAR-WAVE ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; PATTERN DESCRIPTION; TENDINOPATHY; MUSCLE; ELASTICITY; AGREEMENT; STIFFNESS; EXERCISE; ETIOLOGY;
D O I
10.1007/s00256-016-2382-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To establish the test-retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC2.k) and Bland-Altman plot were used to assess test-retest reliability. The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC2.k of 0.84 (95 % CI: 0.64-0.92) for reference material, 0.91 (95 % CI: 0.83-0.95) for Achilles tendons and 0.95 (95 % CI: 0.91-0.97) for Kager fat pads (KFP). The ICC2.k value for skin was 0.30 (95 % CI: -0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC2.k of 0.93 (95 % CI: 0.87-0.96) for reference material, 0.72 (95 % CI: 0.50-0.84) for skin, 0.93 (95 % CI: 0.87-0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66-0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC2.k of 0.87 (95 % CI: 0.75-0.93), and in the contracted state, it was very high with an ICC2.k of 0.94 (95 % CI: 0.90-0.97). Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity.
引用
收藏
页码:1045 / 1052
页数:8
相关论文
共 50 条
  • [41] The Coefficient of Variation of Step Time Can Overestimate Gait Abnormality: Test-Retest Reliability of Gait-Related Parameters Obtained with a Tri-Axial Accelerometer in Healthy Subjects
    Fujiwara, Shunrou
    Sato, Shinpei
    Sugawara, Atsushi
    Nishikawa, Yasumasa
    Koji, Takahiro
    Nishimura, Yukihide
    Ogasawara, Kuniaki
    SENSORS, 2020, 20 (03)
  • [42] Test-retest reliability of time-varying patterns of brain activity across single band and multiband resting-state functional magnetic resonance imaging in healthy older adults
    Cahart, Marie-Stephanie
    Dell'Acqua, Flavio
    Giampietro, Vincent
    Cabral, Joana
    Timmers, Maarten
    Streffer, Johannes
    Einstein, Steven
    Zelaya, Fernando
    Williams, Steven C. R.
    O'Daly, Owen
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [43] Identification of stable endogenous reference genes for real-time PCR in the human fetal gonad using an external standard technique
    O'Shaughnessy, Peter J.
    Monteiro, Ana
    Fowler, Paul A.
    MOLECULAR HUMAN REPRODUCTION, 2011, 17 (10) : 620 - 625
  • [44] SPECT of serotonin transporters using 123I-ADAM:: Optimal imaging time after bolus injection and long-term test-retest in healthy volunteers
    Catafau, AM
    Pérez, V
    Penengo, MM
    Bullich, S
    Danús, M
    Puigdemont, D
    Pascual, JC
    Corripio, I
    Llop, J
    Perich, J
    Alvarez, E
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (08) : 1301 - 1309
  • [45] SPECT of serotonin transporters using 123I-ADAM:: optimal time imaging after bolus injection and long-term test-retest in healthy volunteers
    Catafau, AM
    Pérez, V
    Penengo, M
    Bullich, S
    Danús, M
    Puigdemont, D
    Corripio, I
    Pascual, JC
    Perich, X
    Alvarez, E
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S288 - S288
  • [46] Test-Retest Reliability and Minimum Detectable Change Using the K4b2: Oxygen Consumption, Gait Efficiency, and Heart Rate for Healthy Adults During Submaximal Walking
    Darter, Benjamin J.
    Rodriguez, Kelly M.
    Wilken, Jason M.
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2013, 84 (02) : 223 - 231
  • [47] Real-time RT-PCR detection of Bovine Viral Diarrhoea virus in whole blood using an external RNA reference
    Young, N. J.
    Thomas, C. J.
    Collins, M. E.
    Brownlie, J.
    JOURNAL OF VIROLOGICAL METHODS, 2006, 138 (1-2) : 218 - 222
  • [48] Test-retest reliability of resting-state cerebral blood flow quantification using pulsed Arterial Spin Labeling (PASL) over 3 weeks vs 8 weeks in healthy controls
    Kyrou, Alexandra
    Gruenert, Elina
    Wuethrich, Florian
    Nadesalingam, Niluja
    Chapellier, Victoria
    Nuoffer, Melanie G.
    Pavlidou, Anastasia
    Lefebvre, Stephanie
    Walther, Sebastian
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2024, 341
  • [49] Left Atrial Volumes and Phasic Function in Healthy Children: Reference Values Using Real-Time Three-Dimensional Echocardiography
    Linden, Katharina
    Goldschmidt, Franziska
    Laser, Kai Thorsten
    Winkler, Christian
    Koerperich, Hermann
    Dalla-Pozza, Robert
    Breuer, Johannes
    Herberg, Ulrike
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (08) : 1036 - +
  • [50] Real-time test-bed system development using power hardware-in-the-loop (PHIL) simulation technique for reliability test of DC nano grid
    Kyung-Wook Heo
    Hyun-Jun Choi
    Jee-Hoon Jung
    Journal of Power Electronics, 2020, 20 : 784 - 793