Background Choroidal thickness (CT) measurements differ between swept source optical coherence tomography (SS-OCT) and spectral domain OCT (SD-OCT) devices for point thickness measurements. We aimed to assess the comparability of mean macular CT measurements between SS-OCT and SD-OCT devices. Methods In a prospective cohort study of 25 healthy volunteers, OCT scans were performed sequentially with the deep range imaging (DRI) OCT-1 and Spectralis OCT using standardised imaging protocols. These OCT scans were independently graded by reading centre-certified graders to obtain mean CT in the various Early Treatment Diabetic Retinopathy Study (ETDRS) subfields. Paired t tests and intraclass correlation coefficients (ICCs) were used to compare the measurements. Results The difference in mean central subfield CT between DRI OCT-1 and Spectralis was 49.3 mu m (p<0.001), while differences in CT in various ETDRS subfields varied from 42.1 to 67.2 mu m. After manual adjustment of the segmentation boundaries for the central subfield in the DRI OCT-1, the mean central subfield CT for DRI OCT-1 increased from 263.1 to 293.3 mu m (p<0.001), and the resultant difference between DRI OCT-1 and Spectralis decreased from 49.3 to 19.1 mu m (a decrease of 61.3%; p<0.001). CT between the three-dimensional and radial scanning protocols of the DRI OCT-1 were highly comparable, with differences generally under 10 mu m and ICC of 0.888 for the central subfield. Conclusions CT measurements between automated segmentations from the DRI OCT-1 and manual segmentations on the Spectralis OCT may differ by more than 50 mu m. This difference can be reduced, but not eliminated, by manual adjustment of segmentation boundaries by trained graders, and should be accounted for when comparing results between the two devices.
引用
收藏
页码:995 / 999
页数:5
相关论文
共 50 条
  • [1] Comparison of macular retinal and choroidal thicknesses from Swept Source and Spectral Domain Optical Coherence Tomography
    Cheong, Kai Xiong
    Lim, Louis Wei Yi
    Ngo, Wei Kiong
    Tan, Colin S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] Comparison of choroidal thicknesses using swept source and spectral domain optical coherence tomography in diseased and normal eyes
    Tan, Colin S. H.
    Ngo, Wei Kiong
    Cheong, Kai Xiong
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (03) : 354 - 358
  • [3] Comparison of swept source optical coherence tomography and spectral domain optical coherence tomography in polypoidal choroidal vasculopathy
    Ting, Daniel S. W.
    Cheung, Gemmy C. M.
    Lim, Laurence S.
    Yeo, Ian Y. S.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (09): : 815 - 819
  • [4] Comparison of choroidal thickness measurements between spectral domain optical coherence tomography and swept source optical coherence tomography in children
    Chun On Lee
    Xiujuan Zhang
    Nan Yuan
    Shumin Tang
    Li Jia Chen
    Carol Y. Cheung
    Jason C. Yam
    Scientific Reports, 11
  • [5] Comparison of choroidal thickness measurements between spectral domain optical coherence tomography and swept source optical coherence tomography in children
    Lee, Chun On
    Zhang, Xiujuan
    Yuan, Nan
    Tang, Shumin
    Chen, Li Jia
    Cheung, Carol Y.
    Yam, Jason C.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] Comparison of choroidal thickness measurements using swept source and spectral domain optical coherence tomography in pachychoroid diseases
    Lee, Min-Woo
    Park, Hye-Jin
    Shin, Yong-Il
    Lee, Woo-Hyuk
    Lim, Hyung-Bin
    Kim, Jung-Yeul
    PLOS ONE, 2020, 15 (02):
  • [7] Comparison of penetration depth in choroidal imaging using swept source vs spectral domain optical coherence tomography
    Waldstein, S. M.
    Faatz, H.
    Szimacsek, M.
    Glodan, A-M
    Podkowinski, D.
    Montuoro, A.
    Simader, C.
    Gerendas, B. S.
    Schmidt-Erfurth, U.
    EYE, 2015, 29 (03) : 409 - 415
  • [8] Comparison of penetration depth in choroidal imaging using swept source vs spectral domain optical coherence tomography
    S M Waldstein
    H Faatz
    M Szimacsek
    A-M Glodan
    D Podkowinski
    A Montuoro
    C Simader
    B S Gerendas
    U Schmidt-Erfurth
    Eye, 2015, 29 : 409 - 415
  • [9] Comparison between Spectral Domain and Swept Source Optical Coherence Tomography Angiographic Imaging of Choroidal Neovascularization in Age-Related Macular Degeneration
    Gregori, Giovanni
    Miller, Andrew R.
    Zhang, Qinqin
    Zheng, Fang
    Dias, Joao Rafael
    Yehoshua, Zohar
    Feuer, William J.
    Chen, Chieh-Li
    Kubach, Sophie
    Durbin, Mary K.
    Wang, Ruikang K.
    Rosenfeld, Philip J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [10] Comparison of Retinal Thicknesses Measured Using Swept-Source and Spectral-Domain Optical Coherence Tomography Devices
    Tan, Colin S.
    Chan, Joel C.
    Cheong, Kai Xiong
    Ngo, Wei Kiong
    Sadda, SriniVas R.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (02): : 172 - 179