Comparison of choroidal thickness measurements between spectral domain optical coherence tomography and swept source optical coherence tomography in children

被引:0
|
作者
Chun On Lee
Xiujuan Zhang
Nan Yuan
Shumin Tang
Li Jia Chen
Carol Y. Cheung
Jason C. Yam
机构
[1] The Chinese University of Hong Kong,Department of Ophthalmology and Visual Sciences
[2] Prince of Wales Hospital,Department of Ophthalmology and Visual Sciences
[3] Hong Kong Eye Hospital,undefined
来源
Scientific Reports | / 11卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Choroidal thickness is associated with many ocular conditions, interchangeability among different generations of optical coherence tomography is therefore important for both research purpose and clinical application. Hence, we compared choroidal thickness measurements between spectral-domain optical coherence tomography (SD-OCT) and swept-source optical coherence tomography (SS-OCT) in healthy paediatric eyes. A total of 114 children from the population-based Hong Kong Children Eye Study with mean age of 7.38 ± 0.82 years were included. Choroidal thickness of the right eye was measured by both devices. The central foveal choroidal thickness (CFCT) measured by SD-OCT and SS-OCT was 273.24 ± 54.29 μm and 251.84 ± 47.12 μm respectively. Inter-device correlation coefficient was 0.840 (95% CI 0.616–0.918). However, choroidal thickness obtained by SD-OCT was significantly thicker than that measured by SS-OCT with a mean difference of 21.40 ± 33.13 μm (P < 0.001). Bland–Altman limit of agreement on the relative difference scale for SD-OCT/SS-OCT was 86.33 μm. Validated conversion equation for translating SD-OCT CFCT measurement into SS-OCT was SS-OCT = 35.261 + 0.810 × SD-OCT. In conclusion, intra-class correlation coefficient (ICC) shows an acceptable agreement between SD-OCT and SS-OCT, however, there was a significant inter-device difference of choroidal thickness measurements in normal children eyes. Therefore, the measurements are not interchangeable.
引用
收藏
相关论文
共 50 条
  • [1] Comparison of choroidal thickness measurements between spectral domain optical coherence tomography and swept source optical coherence tomography in children
    Lee, Chun On
    Zhang, Xiujuan
    Yuan, Nan
    Tang, Shumin
    Chen, Li Jia
    Cheung, Carol Y.
    Yam, Jason C.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Comparison of swept source optical coherence tomography and spectral domain optical coherence tomography in polypoidal choroidal vasculopathy
    Ting, Daniel S. W.
    Cheung, Gemmy C. M.
    Lim, Laurence S.
    Yeo, Ian Y. S.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (09): : 815 - 819
  • [3] Comparison of choroidal thickness measurements using swept source and spectral domain optical coherence tomography in pachychoroid diseases
    Lee, Min-Woo
    Park, Hye-Jin
    Shin, Yong-Il
    Lee, Woo-Hyuk
    Lim, Hyung-Bin
    Kim, Jung-Yeul
    PLOS ONE, 2020, 15 (02):
  • [4] Comparison of Spectral-Domain and Swept-Source Optical Coherence Tomography Choroidal Thickness Measurements in Normal Eyes
    Luu, Jennifer Yen
    Sha, Patricia
    Durbin, Mary K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [5] A comparative analysis of choroidal thickness map in healthy eyes using spectral domain optical coherence tomography and swept source optical coherence tomography
    Lee, Byung Ro
    Shin, Yong Un
    Lim, Han Woong
    Lee, Sang Hyup
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Comparison of macular choroidal thicknesses from swept source and spectral domain optical coherence tomography
    Tan, Colin S.
    Cheong, Kai Xiong
    Lim, Louis W.
    Sadda, SriniVas R.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (07) : 995 - 999
  • [7] Choroidal Analysis in Healthy Eyes Using Swept-Source Optical Coherence Tomography Compared to Spectral Domain Optical Coherence Tomography
    Adhi, Mehreen
    Liu, Jonathan J.
    Qavi, Ahmed H.
    Grulkowski, Ireneusz
    Lu, Chen D.
    Mohler, Kathrin J.
    Ferrara, Daniela
    Kraus, Martin F.
    Baumal, Caroline R.
    Witkin, Andre J.
    Waheed, Nadia K.
    Hornegger, Joachim
    Fujimoto, James G.
    Duker, Jay S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (06) : 1272 - 1281
  • [8] Choroidal thickness in the era of swept-source optical coherence tomography
    Agarwal, Aniruddha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 256 - 257
  • [9] Comparison of macular retinal and choroidal thicknesses from Swept Source and Spectral Domain Optical Coherence Tomography
    Cheong, Kai Xiong
    Lim, Louis Wei Yi
    Ngo, Wei Kiong
    Tan, Colin S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [10] A comparison of image quality between swept source optical coherence tomography and spectral domain optical coherence tomography according to ocular media opacity
    Shin, Yong Un
    Lee, Byung Ro
    Lim, Han Woong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)