Urinary tract infections in children: Testing a novel, noninvasive, point-of-care diagnostic marker

被引:4
|
作者
Lubell, Tamar R. [1 ]
Barasch, Jonathan M. [2 ,3 ]
King, Benjamin [4 ,5 ]
Ochs, Julie B. [1 ,6 ]
Fan, Weijia [7 ]
Duong, Jimmy [7 ]
Chitre, Manasi [1 ,8 ]
Dayan, Peter S. [1 ]
机构
[1] Columbia Univ, Dept Emergency Med, Div Pediat Emergency Med, Vagelos Coll Phys & Surg, New York, NY 10032 USA
[2] Columbia Univ, Div Nephrol, Dept Med, Vagelos Coll Phys & Surg, New York, NY 10032 USA
[3] Columbia Univ, Div Nephrol, Dept Pathol & Cell Biol, Vagelos Coll Phys & Surg, New York, NY 10032 USA
[4] Columbia Univ, Dept Pediat, Vagelos Coll Phys & Surg, New York, NY 10032 USA
[5] Weill Cornell Med, Dept Primary Care, New York, NY USA
[6] New York Inst Technol, Coll Osteopath Med, Old Westbury, NY 11568 USA
[7] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, New York, NY USA
[8] Albert Einstein Coll Med, Div Pediat Emergency Med, Dept Pediat, Bronx, NY 10467 USA
关键词
biomarkers; pediatric emergency medicine; urinary tract infections; GELATINASE-ASSOCIATED LIPOCALIN; INFANTS; URINALYSIS; BIOMARKERS; KIDNEY;
D O I
10.1111/acem.14402
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives Urinary neutrophil gelatinase-associated lipocalin (uNGAL) appears highly accurate to identify urinary tract infections (UTIs) when obtained via catheterization. Our primary aim was to determine the agreement in uNGAL levels between paired catheter and bag urine specimens. Our secondary aim was to compare the diagnostic test characteristics of quantitative uNGAL, dipstick uNGAL (a potential point-of-care test), and urinalysis (UA). Methods This was a prospective study of febrile children < 24 months evaluated for UTIs. We evaluated quantitative uNGAL at a previously identified threshold of 39.1 ng/mL, dipstick uNGAL at its built-in threshold of >50 ng/mL, and UA at standard thresholds for leukocyte esterase (LE). A positive urine culture was defined as >100,000 CFUs/mL of a pathogen. Results A total of 211 patients were included (10% with positive urine cultures); 116 had paired catheterized and bagged samples. The agreement between catheterized and bagged samples at a quantitative uNGAL cutoff of >= 39.1 ng/mL was 0.76 (95% confidence interval [CI] = 0.67 to 0.83) and 0.77 (95% CI = 0.68 to 0.84) at a uNGAL dipstick threshold of >50 ng/mL. The area under the receiver operating characteristic curve for uNGAL from a catheterized sample was 0.96 (95% CI = 0.89 to 1.00) compared to 0.93 (95% CI = 0.87 to -0.99) from a bagged sample. The sensitivities of catheterized sample quantitative and dipstick uNGAL (90.5%) were higher than UA at a LE threshold of >= 1+ (57.1%). Bagged-sample uNGAL had lower quantitative and dipstick specificities (both 73.8%) than from catheterized samples (94.3% and 95.3% respectively), similar to UA. Conclusions uNGAL from bagged and catheterized samples showed insufficient agreement to be used interchangeably. The low specificity of uNGAL from bagged samples suggests that sampling technique affects uNGAL levels.
引用
收藏
页码:326 / 333
页数:8
相关论文
共 50 条
  • [31] Point-of-Care Urinary Cotinine Testing as a Marker of Smoking Status in Surgical Patients: A Systematic Review
    Vyas, R.
    Rollett, R.
    Bagirathan, S.
    Fennell, N.
    BRITISH JOURNAL OF SURGERY, 2019, 106 : 123 - 123
  • [32] Diagnostic test accuracy of point-of-care procalcitonin to diagnose serious bacterial infections in children
    Waterfield, Thomas
    Maney, Julie-Ann
    Lyttle, Mark D.
    McKenna, James P.
    Roland, Damian
    Corr, Michael
    Patenall, Bethany
    Shields, Michael D.
    Woolfall, Kerry
    Fairley, Derek
    BMC PEDIATRICS, 2020, 20 (01)
  • [33] Diagnostic test accuracy of point-of-care procalcitonin to diagnose serious bacterial infections in children
    Thomas Waterfield
    Julie-Ann Maney
    Mark D Lyttle
    James P McKenna
    Damian Roland
    Michael Corr
    Bethany Patenall
    Michael D Shields
    Kerry Woolfall
    Derek Fairley
    BMC Pediatrics, 20
  • [34] A fidget spinner for the point-of-care diagnosis of urinary tract infection
    Issac Michael
    Dongyoung Kim
    Oleksandra Gulenko
    Sumit Kumar
    Saravana Kumar
    Jothi Clara
    Dong Yeob Ki
    Juhee Park
    Hyun Yong Jeong
    Taek Soo Kim
    Sunghoon Kwon
    Yoon-Kyoung Cho
    Nature Biomedical Engineering, 2020, 4 : 591 - 600
  • [35] A fidget spinner for the point-of-care diagnosis of urinary tract infection
    Michael, Issac
    Kim, Dongyoung
    Gulenko, Oleksandra
    Kumar, Sumit
    Kumar, Saravana
    Clara, Jothi
    Ki, Dong Yeob
    Park, Juhee
    Jeong, Hyun Yong
    Kim, Taek Soo
    Kwon, Sunghoon
    Cho, Yoon-Kyoung
    NATURE BIOMEDICAL ENGINEERING, 2020, 4 (06) : 591 - 600
  • [36] Quality assurance for point-of-care diagnostic testing: It is not negotiable
    Murtagh, Maurine M.
    AFRICAN JOURNAL OF LABORATORY MEDICINE, 2016, 5 (02)
  • [37] Improving diagnostic antimicrobial stewardship in respiratory tract infections: a protocol for a scoping review investigating point-of-care testing programmes in community pharmacy
    Saha, Sajal K.
    Promite, Shukla
    Botheras, Carly L.
    Manias, Elizabeth
    Mothobi, Nomvuyo
    Robinson, Suzanne
    Athan, Eugene
    BMJ OPEN, 2023, 13 (02):
  • [38] Point-of-care testing for procalcitonin in identifying bacterial infections in young infants: a diagnostic accuracy study
    Thomas Waterfield
    Julie-Ann Maney
    Martin Hanna
    Derek Fairley
    Michael D. Shields
    BMC Pediatrics, 18
  • [39] Point-of-Care Serum Amyloid A as a Diagnostic Marker for Neonatal Sepsis
    Vishakha Sharma
    Rajat Grover
    Mayank Priyadarshi
    Suman Chaurasia
    Nowneet Kumar Bhat
    Sriparna Basu
    Poonam Singh
    Indian Journal of Pediatrics, 2024, 91 : 571 - 577
  • [40] Point-of-Care Serum Amyloid A as a Diagnostic Marker for Neonatal Sepsis
    Sharma, Vishakha
    Grover, Rajat
    Priyadarshi, Mayank
    Chaurasia, Suman
    Bhat, Nowneet Kumar
    Basu, Sriparna
    Singh, Poonam
    INDIAN JOURNAL OF PEDIATRICS, 2024, 91 (06): : 571 - 577