The development of an ICT-based formaldehyde-responsive fluorescence turn-on probe with a high signal-to-noise ratio

被引:40
|
作者
Yang, Xueling [1 ]
He, Longwei [1 ]
Xu, Kaixin [1 ]
Yang, Yunzhen [1 ]
Lin, Weiying [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Inst Fluorescent Probes Biol Imaging, Sch Mat Sci & Engn, Jinan 250022, Shandong, Peoples R China
关键词
MONITORING FORMALDEHYDE; LIVING CELLS; SENSOR; PRECONCENTRATION; MALONDIALDEHYDE; FLUOROPHORE; CYSTEINE; TISSUE; SERUM;
D O I
10.1039/c8nj02467g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An illuminating ICT-based formaldehyde-responsive fluorescent probe (PBD-FA) with long wavelength emission was judiciously designed and synthesized, which is suitable for detecting FA in aqueous solution and living cells, both with significant fluorescence signal-to-noise ratios.
引用
收藏
页码:12361 / 12364
页数:4
相关论文
共 50 条
  • [1] An ICT-Based Mitochondria-Targeted Fluorescent Probe for Hydrogen Peroxide with a Large Turn-On Fluorescence Signal
    Liang, Xiao
    Zhang, Lu
    Xu, Xiaoyi
    Qiao, Dan
    Shen, Tangliang
    Yin, Zheng
    Shang, Luqing
    CHEMISTRYSELECT, 2019, 4 (04): : 1330 - 1336
  • [2] Rational design of an iminocoumarin-based fluorescence probe for peroxynitrite with high signal-to-noise ratio
    Huang, Zejian
    Shi, Lei
    Liu, Huihong
    Zhou, Zu-Kun
    Xiang, Hua
    Gong, Shengzhao
    Mao, Guojiang
    Shao, Guang
    Yang, Sheng
    LUMINESCENCE, 2024, 39 (02)
  • [3] Rapid detection of CO in vitro and in vivo with a ratiometric probe showing near-infrared turn-on fluorescence, large Stokes shift, and high signal-to-noise ratio
    Zhou, Enbo
    Gong, Shengyi
    Feng, Guoqiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 301
  • [4] An improved bimolecular fluorescence complementation assay with a high signal-to-noise ratio
    Kodama, Yutaka
    Hu, Chang-Deng
    BIOTECHNIQUES, 2010, 49 (05) : 793 - +
  • [5] Cascaded Optical Kerr Gate for Fluorescence Measurement With High Signal-to-Noise Ratio
    Huang, Zhenqiang
    Kang, Zhen
    Tan, Wenjiang
    Si, Jinhai
    Hou, Xun
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2024, 36 (01) : 55 - 58
  • [6] An ESIPT based fluorescent probe for imaging hydrogen sulfide with a large turn-on fluorescence signal
    Deng, Beibei
    Ren, Mingguang
    Kong, Xiuqi
    Zhou, Kai
    Lin, Weiying
    RSC ADVANCES, 2016, 6 (67): : 62406 - 62410
  • [7] Selective naked eye and "turn-on" fluorescence chemodosimeter for CN- by activated Michael acceptor possessing different polar substituents: Reduced ICT-based signal transduction
    Maurya, Nirma
    Singh, Ashok Kumar
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 245 : 74 - 80
  • [8] Use of independent component analysis to improve signal-to-noise ratio in multi-probe fluorescence microscopy
    Dao, L.
    Lucotte, B.
    Glancy, B.
    Chang, L. -C.
    Hsu, L. -Y.
    Balaban, R. S.
    JOURNAL OF MICROSCOPY, 2014, 256 (02) : 133 - 144
  • [9] A rapid-responsive fluorescent probe based on coumarin for selective sensing of sulfite in aqueous solution and its bioimaging by turn-on fluorescence signal
    Wang, Lei
    Li, Wenxuan
    Zhi, Wenjing
    Ye, Dandan
    Wang, Yun
    Ni, Liang
    Bao, Xu
    DYES AND PIGMENTS, 2017, 147 : 357 - 363
  • [10] A fast-responsive two-photon fluorescent probe for detecting palladium(0) with a large turn-on fluorescence signal
    Wang, Jian-Yong
    Liu, Zhan-Rong
    Ren, Mingguang
    Deng, Beibei
    Lin, Weiying
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2016, 317 : 108 - 114