Rational design of an iminocoumarin-based fluorescence probe for peroxynitrite with high signal-to-noise ratio

被引:0
|
作者
Huang, Zejian [1 ]
Shi, Lei [1 ,5 ]
Liu, Huihong [2 ]
Zhou, Zu-Kun [3 ]
Xiang, Hua [1 ]
Gong, Shengzhao [1 ]
Mao, Guojiang [4 ]
Shao, Guang [3 ,6 ]
Yang, Sheng [2 ,7 ]
机构
[1] Guangdong Ind Polytech, Guangdong Engn Tech Res Ctr Green Household Chem, Sch Chem Engn & Technol, Guangzhou, Peoples R China
[2] Hunan Normal Univ, Coll Chem & Chem Engn, Lab Chem Biol & Tradit Chinese Med Res, Minist Educ, Changsha, Peoples R China
[3] Sun Yat Sen Univ, Sch Chem, Guangzhou, Guangdong, Peoples R China
[4] Henan Normal Univ, Collaborat Innovat Ctr Henan Prov Green Mfg Fine C, Henan Key Lab Organ Funct Mol & Drug Innovat, Sch Chem & Chem Engn,Minist Educ,Key Lab Green Che, Xinxiang 453007, Henan, Peoples R China
[5] Guangdong Ind Polytech, Sch Light Chem Technol, Guangdong Engn Tech Res Ctr Green Household Chem, Guangzhou 510300, Guangdong, Peoples R China
[6] Sun Yat Sen Univ, Sch Chem, Guangzhou 510275, Guangdong, Peoples R China
[7] Hunan Normal Univ, Coll Chem & Chem Engn, Lab Chem Biol & Tradit Chinese Med Res, Minist Educ, Changsha 410081, Peoples R China
关键词
fluorescent probe; peroxynitrite; iminocourmarin; bioimaging; BIOCHEMISTRY; PROGRESS; OXIDE; TICT;
D O I
10.1002/bio.4697
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As a high reactive oxygen species (ROS) and a reactive nitrogen species (RNS), peroxynitrite anion (ONOO-) is widely present in organisms and plays influential roles in physiological and pathological processes. It is of great significance to develop effective fluorescent probes for imaging peroxynitrite variation in living systems. Herein we present a novel fluorescent probe TQC0 for monitoring ONOO- based on the iminocoumarin platform, and this probe was synthesized by the knoevenagel condensation between a dihydropyridine-salicylaldehyde derivative and 2-benzothiazole-acetonitrile, and subsequently masked with the boronate moiety. The obtained probe TQC0 exhibited a high signal-to-noise ratio (206-fold) and a quick 'turn-on' response (about 10 min) with great selectivity and sensitivity. Furthermore, the probe TQC0 was successfully applied for imaging ONOO- in living cells with low cytotoxicity. A novel fluorescent probe TQC0 was rationally designed and synthesized for monitoring peroxynitrite anion (ONOO-) based on the iminocoumarin scaffold. This probe exhibited 206-fold enhancement and a quick 'turn-on' response (about 10 min) toward ONOO- with great selectivity and high sensitivity, which enabled the probe TQC0 to visualize ONOO- in living cells. image
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Optimization of signal-to-noise ratio for efficient microarray probe design
    Matveeva, Olga V.
    Nechipurenko, Yury D.
    Riabenko, Evgeniy
    Ragan, Chikako
    Nazipova, Nafisa N.
    Ogurtsov, Aleksey Y.
    Shabalina, Svetlana A.
    BIOINFORMATICS, 2016, 32 (17) : 552 - 558
  • [2] The development of an ICT-based formaldehyde-responsive fluorescence turn-on probe with a high signal-to-noise ratio
    Yang, Xueling
    He, Longwei
    Xu, Kaixin
    Yang, Yunzhen
    Lin, Weiying
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (15) : 12361 - 12364
  • [3] Theoretical studies on the structural and spectroscopic properties of an iminocoumarin-based probe and its metal complexation: an implication for a fluorescence probe
    Guo, Yuan-Ru
    Li, Xing-Rui
    Zhang, Ming-Jing
    Pan, Qing-Jiang
    Sun, Zhong-Ming
    DALTON TRANSACTIONS, 2013, 42 (36) : 13004 - 13013
  • [4] Approach to the Design of a Polarization Maintaining Fiber Electric Field Probe for High Signal-to-Noise Ratio
    Kim, Seung Kwan
    Lim, Sun Do
    Lee, Dong-Joon
    Hwang, In-June
    Hong, Young-Pyo
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2022, 40 (19) : 6576 - 6582
  • [5] An improved bimolecular fluorescence complementation assay with a high signal-to-noise ratio
    Kodama, Yutaka
    Hu, Chang-Deng
    BIOTECHNIQUES, 2010, 49 (05) : 793 - +
  • [6] Design of phase only DOEs with a high signal-to-noise ratio
    Meister, M
    Winfield, RJ
    OPTO-IRELAND 2002: OPTICS AND PHOTONICS TECHNOLOGIES AND APPLICATIONS, PTS 1 AND 2, 2003, 4876 : 1045 - 1053
  • [7] Cascaded Optical Kerr Gate for Fluorescence Measurement With High Signal-to-Noise Ratio
    Huang, Zhenqiang
    Kang, Zhen
    Tan, Wenjiang
    Si, Jinhai
    Hou, Xun
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2024, 36 (01) : 55 - 58
  • [8] Design of a Poly Silicon MEMS Microphone for High Signal-to-Noise Ratio
    Dehe, Alfons
    Wurzer, Martin
    Fueldner, Marc
    Krumbein, Ulrich
    2013 PROCEEDINGS OF THE EUROPEAN SOLID-STATE DEVICE RESEARCH CONFERENCE (ESSDERC), 2013, : 292 - 295
  • [9] Signal-to-noise ratio analysis and improvement for fluorescence tomography imaging
    Wang, Huiquan
    Feng, Xing
    Shi, Boya
    Liang, Wenxuan
    Chen, Yongping
    Wang, Jinhai
    Li, Xingde
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (09):
  • [10] Theoretical investigation of the signal-to-noise ratio in fluorescence lifetime imaging
    Philip, J
    Carlsson, K
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (02): : 368 - 379