Rational design of an iminocoumarin-based fluorescence probe for peroxynitrite with high signal-to-noise ratio

被引:0
|
作者
Huang, Zejian [1 ]
Shi, Lei [1 ,5 ]
Liu, Huihong [2 ]
Zhou, Zu-Kun [3 ]
Xiang, Hua [1 ]
Gong, Shengzhao [1 ]
Mao, Guojiang [4 ]
Shao, Guang [3 ,6 ]
Yang, Sheng [2 ,7 ]
机构
[1] Guangdong Ind Polytech, Guangdong Engn Tech Res Ctr Green Household Chem, Sch Chem Engn & Technol, Guangzhou, Peoples R China
[2] Hunan Normal Univ, Coll Chem & Chem Engn, Lab Chem Biol & Tradit Chinese Med Res, Minist Educ, Changsha, Peoples R China
[3] Sun Yat Sen Univ, Sch Chem, Guangzhou, Guangdong, Peoples R China
[4] Henan Normal Univ, Collaborat Innovat Ctr Henan Prov Green Mfg Fine C, Henan Key Lab Organ Funct Mol & Drug Innovat, Sch Chem & Chem Engn,Minist Educ,Key Lab Green Che, Xinxiang 453007, Henan, Peoples R China
[5] Guangdong Ind Polytech, Sch Light Chem Technol, Guangdong Engn Tech Res Ctr Green Household Chem, Guangzhou 510300, Guangdong, Peoples R China
[6] Sun Yat Sen Univ, Sch Chem, Guangzhou 510275, Guangdong, Peoples R China
[7] Hunan Normal Univ, Coll Chem & Chem Engn, Lab Chem Biol & Tradit Chinese Med Res, Minist Educ, Changsha 410081, Peoples R China
关键词
fluorescent probe; peroxynitrite; iminocourmarin; bioimaging; BIOCHEMISTRY; PROGRESS; OXIDE; TICT;
D O I
10.1002/bio.4697
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As a high reactive oxygen species (ROS) and a reactive nitrogen species (RNS), peroxynitrite anion (ONOO-) is widely present in organisms and plays influential roles in physiological and pathological processes. It is of great significance to develop effective fluorescent probes for imaging peroxynitrite variation in living systems. Herein we present a novel fluorescent probe TQC0 for monitoring ONOO- based on the iminocoumarin platform, and this probe was synthesized by the knoevenagel condensation between a dihydropyridine-salicylaldehyde derivative and 2-benzothiazole-acetonitrile, and subsequently masked with the boronate moiety. The obtained probe TQC0 exhibited a high signal-to-noise ratio (206-fold) and a quick 'turn-on' response (about 10 min) with great selectivity and sensitivity. Furthermore, the probe TQC0 was successfully applied for imaging ONOO- in living cells with low cytotoxicity. A novel fluorescent probe TQC0 was rationally designed and synthesized for monitoring peroxynitrite anion (ONOO-) based on the iminocoumarin scaffold. This probe exhibited 206-fold enhancement and a quick 'turn-on' response (about 10 min) toward ONOO- with great selectivity and high sensitivity, which enabled the probe TQC0 to visualize ONOO- in living cells. image
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A nontoxic, photostable and high signal-to-noise ratio mitochondrial probe with mitochondrial membrane potential and viscosity detectivity
    Chen, Yanan
    Qi, Jianguo
    Huang, Jing
    Zhou, Xiaomin
    Niu, Linqiang
    Yan, Zhijie
    Wang, Jianhong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 189 : 634 - 641
  • [32] Research on the optimization method for PGNAA system design based on Signal-to-Noise Ratio evaluation
    Li, JiaTong
    Jia, WenBao
    Hei, DaQian
    Yao, Zeen
    Cheng, Can
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (06) : 2221 - 2229
  • [33] Design of FIR Fractional Delay Filter Based on Maximum Signal-to-Noise Ratio Criterion
    Tseng, Chien-Cheng
    Lee, Su-Ling
    2013 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA), 2013,
  • [34] Signal Detection Algorithm Design Based on Stochastic Resonance Technology Under Low Signal-to-Noise Ratio
    Jiang X.
    Diao M.
    Qu S.
    Journal of Shanghai Jiaotong University (Science), 2019, 24 (03) : 328 - 334
  • [35] Signal Detection Algorithm Design Based on Stochastic Resonance Technology Under Low Signal-to-Noise Ratio
    江晓林
    刁鸣
    渠苏苏
    Journal of Shanghai Jiaotong University(Science), 2019, 24 (03) : 328 - 334
  • [36] On Noncoherent Fading Relay Channels at High Signal-to-Noise Ratio
    Koch, Tobias
    Kramer, Gerhard
    IEEE TRANSACTIONS ON INFORMATION THEORY, 2013, 59 (04) : 2221 - 2241
  • [37] High signal-to-noise ratio observations of EC 14026 pulsators
    Billères, M
    Fontaine, G
    WHITE DWARFS, 2003, 105 : 65 - 68
  • [38] HIGH SIGNAL-TO-NOISE RATIO - THE SPECTROSCOPIC KEY TO ALGOL SYSTEMS
    TOMKIN, J
    SPACE SCIENCE REVIEWS, 1989, 50 (1-2) : 245 - 255
  • [39] Microfluidic chip detection instrument with high signal-to-noise ratio
    Cai, EL
    Cen, ZF
    Li, XT
    Lin, YQ
    Huang, XM
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 1, 2004, : 1282 - 1285
  • [40] SIGNAL-TO-NOISE RATIO MODELS FOR HIGH-DENSITY RECORDING
    FINKELSTEIN, BI
    CHRISTENSEN, ER
    IEEE TRANSACTIONS ON MAGNETICS, 1986, 22 (05) : 898 - 900