Conventional balloon angioplasty versus peripheral cutting balloon angioplasty for treatment of femoropopliteal artery in-stent restenosis: Initial experience

被引:132
|
作者
Dick, Petra [1 ]
Sabeti, Schila [1 ]
Mlekusch, Wolfgang [1 ]
Schlager, Oliver [1 ]
Amighi, Jasmin [1 ]
Haumer, Markus [1 ]
Cejna, Manfred [1 ]
Minar, Erich [1 ]
Schillinger, Martin [1 ]
机构
[1] Vienna Gen Hosp, Dept Internal Med 2, Div Angiol, Sch Med, A-1090 Vienna, Austria
关键词
D O I
10.1148/radiol.2481071159
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively determine whether cutting balloon angioplasty, when compared with conventional balloon angioplasty (CBA), improves morphologic and clinical outcome in patients with femoropopliteal in-stent restenosis. Materials and Methods: Patients with symptomatic femoropopliteal in-stent restenosis were randomly assigned to undergo CBA or peripheral cutting balloon angioplasty (PCBA) for treatment of lesions up to 20 cm in length. Patients were followed up clinically and with duplex ultrasonography (US) at 1, 3, and 6 months for occurrence of a restenosis of 50% or higher. The Fisher exact test and Mann Whitney U test were used for statistical analyses. Results: Forty patients were enrolled; one patient was lost to follow-up. In the remaining patients, CBA was performed in 22 patients; PCBA was used in 17 patients. Average lesion length was 80 mm +/- 68 (standard deviation). Restenosis rates at 6 months were 65% (11 of 17; 95% confidence interval: 42%, 88%) after PCBA versus 73% (16 of 22; 95% confidence interval: 54%, 92%) after CBA (P = .73). Ankle brachial index (0.83 vs 0.75, P = .26) and maximum walking capacity on the treadmill (117 m vs 103 m, P = .97) at 6 months were also not significantly different between the two groups. Conclusion: PCBA failed to prove superiority compared with CBA for treatment of femoropopliteal in-stent restenosis in this pilot study. In restenotic lesions with an average length of approximately 8 cm, both treatment modalities yielded disappointing 6-month patency rates.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [1] Cutting balloon angioplasty versus balloon angioplasty for treating diffuse in-stent restenosis
    Spanos, V
    Sarais, C
    Toutouzas, K
    Moshiri, S
    Montorfano, M
    Briguori, C
    Stankovic, G
    Colombo, A
    EUROPEAN HEART JOURNAL, 2002, 23 : 553 - 553
  • [2] Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis - Results of the Restenosis Cutting Balloon Evaluation Trial (RESCUT)
    Albiero, R
    Silber, S
    Di Mario, C
    Cernigliaro, C
    Battaglia, S
    Reimers, B
    Frasheri, A
    Klauss, V
    Auge, JM
    Rubartelli, P
    Morice, MC
    Cremonesi, A
    Schofer, J
    Bortone, A
    Colombo, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (06) : 943 - 949
  • [3] Cutting balloon angioplasty for treatment of in-stent restenosis
    Lauer, B
    Schmidt, B
    Stellbring, S
    Ambrosch, H
    Boudriot, E
    Diederich, K
    Hambrecht, R
    Krankenberg, H
    Sick, P
    Zotz, R
    Schuler, G
    CIRCULATION, 2000, 102 (18) : 365 - 365
  • [4] Cutting Balloon angioplasty for the treatment of in-stent restenosis
    Albiero, R
    Nishida, T
    Karvouni, E
    Corvaja, N
    Vaghetti, M
    Di Mario, C
    Colombo, A
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (04) : 452 - 459
  • [5] The impact of Cutting Balloon Angioplasty for the treatment of diffuse In-Stent Restenosis. Comparison with conventional balloon angioplasty
    Iijima, R
    Nakamura, M
    Kitagawa, Y
    Nakajima, R
    Yoshitama, T
    Takagi, T
    Anzai, H
    Tunoda, T
    Yamaguchi, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 80A - 80A
  • [6] Cutting Balloon angioplasty for in-stent restenosis
    Kurbaan, AS
    Foale, RA
    Sigwart, U
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (04) : 480 - 483
  • [7] Drug-eluting balloon angioplasty versus uncoated balloon angioplasty for the treatment of in-stent restenosis of the femoropopliteal arteries
    Kayssi, Ahmed
    Al-Jundi, Wissam
    Papia, Giuseppe
    Kucey, Daryl S.
    Forbes, Thomas
    Rajan, Dheeraj K.
    Neville, Richard
    Dueck, Andrew D.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (01):
  • [8] Preliminary experience with cutting balloon angioplasty for iliac artery in-stent restenosis
    Tsetis, Dimitrios
    Belli, Anna Maria
    Morgan, Robert
    Basile, Antonio
    Kostas, Theodoros
    Manousaki, Eirini
    Katsamouris, Asterios
    Gourtsoyiannis, Nicholas
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (02) : 193 - 202
  • [9] The efficiency of cutting balloon angioplasty in the treatment of in-stent restenosis
    Ates, Haci
    Duygu, Hamza
    Cakir, Cayan
    Acet, Halit
    Akdemir, Sefa
    Akyildiz, Zehra Ilke
    Kocabas, Ugur
    Nazli, Cem
    Ergene, Oktay
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2011, 11 (05): : 436 - 440
  • [10] Drug-eluting stent versus balloon angioplasty for treatment of femoropopliteal in-stent restenosis
    Murata, N.
    Takahara, M.
    Soga, Y.
    Tosaka, A.
    Iida, O.
    Tanaka, N.
    Yamashina, A.
    EUROPEAN HEART JOURNAL, 2016, 37 : 76 - 76