Cutting Balloon angioplasty for the treatment of in-stent restenosis

被引:1
|
作者
Albiero, R [1 ]
Nishida, T [1 ]
Karvouni, E [1 ]
Corvaja, N [1 ]
Vaghetti, M [1 ]
Di Mario, C [1 ]
Colombo, A [1 ]
机构
[1] EMO Ctr Cuore Columbus, I-20145 Milan, Italy
关键词
coronary angioplasy; Cutting Balloon; restenosis; stents;
D O I
10.1002/1522-726X(200008)50:4<452::AID-CCD19>3.0.CO;2-W
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The results using the Cutting Balloon for the treatment of in-stent restenosis may be superior to those of conventional percutaneous transluminal coronary angioplasty (PTCA) or even the combination of PTCA preceded by rotational atherectomy, The reasons for these possible differences are not yet well defined, The case we report suggests that the Cutting Balloon achieves a better final result than conventional PTCA, by making the tissue more amenable to being pushed outward through the stent struts, Cathet Cardiovasc. Intervent 50:452-459, 2000 (C) 2000 Wiley-Liss, Inc.
引用
收藏
页码:452 / 459
页数:8
相关论文
共 50 条
  • [1] Cutting balloon angioplasty for treatment of in-stent restenosis
    Lauer, B
    Schmidt, B
    Stellbring, S
    Ambrosch, H
    Boudriot, E
    Diederich, K
    Hambrecht, R
    Krankenberg, H
    Sick, P
    Zotz, R
    Schuler, G
    CIRCULATION, 2000, 102 (18) : 365 - 365
  • [2] Cutting Balloon angioplasty for in-stent restenosis
    Kurbaan, AS
    Foale, RA
    Sigwart, U
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (04) : 480 - 483
  • [3] The efficiency of cutting balloon angioplasty in the treatment of in-stent restenosis
    Ates, Haci
    Duygu, Hamza
    Cakir, Cayan
    Acet, Halit
    Akdemir, Sefa
    Akyildiz, Zehra Ilke
    Kocabas, Ugur
    Nazli, Cem
    Ergene, Oktay
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2011, 11 (05): : 436 - 440
  • [4] Cutting balloon angioplasty for in-stent restenosis.
    Stankovic, G
    Albiero, R
    Di Mario, C
    Corvaja, N
    Nishida, T
    Vaghetti, M
    Sivieri, G
    Colombo, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (8A): : 24I - 24I
  • [5] Cutting balloon angioplasty versus balloon angioplasty for treating diffuse in-stent restenosis
    Spanos, V
    Sarais, C
    Toutouzas, K
    Moshiri, S
    Montorfano, M
    Briguori, C
    Stankovic, G
    Colombo, A
    EUROPEAN HEART JOURNAL, 2002, 23 : 553 - 553
  • [6] Cutting Balloon Combined with Drug-Coated Balloon Angioplasty for the Treatment of In-Stent Restenosis
    Zheng, You-Cheng
    Lee, Wei-Chieh
    Fang, Hsiu-Yu
    Chen, Chien-Jen
    Yang, Cheng-Hsu
    Wu, Chiung-Jen
    Fang, Chih-Yuan
    INTERNATIONAL HEART JOURNAL, 2021, 62 (06) : 1213 - 1220
  • [7] Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis - Results of the Restenosis Cutting Balloon Evaluation Trial (RESCUT)
    Albiero, R
    Silber, S
    Di Mario, C
    Cernigliaro, C
    Battaglia, S
    Reimers, B
    Frasheri, A
    Klauss, V
    Auge, JM
    Rubartelli, P
    Morice, MC
    Cremonesi, A
    Schofer, J
    Bortone, A
    Colombo, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (06) : 943 - 949
  • [8] The impact of Cutting Balloon Angioplasty for the treatment of diffuse In-Stent Restenosis. Comparison with conventional balloon angioplasty
    Iijima, R
    Nakamura, M
    Kitagawa, Y
    Nakajima, R
    Yoshitama, T
    Takagi, T
    Anzai, H
    Tunoda, T
    Yamaguchi, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 80A - 80A
  • [9] Cutting balloon angioplasty for the treatment of in-stent restenosis: A matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty
    Adamian, M
    Colombo, A
    Briguori, C
    Nishida, T
    Marsico, F
    Di Mario, C
    Albiero, R
    Moussa, I
    Moses, JW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) : 672 - 679
  • [10] Intracoronary β-radiation combined with cutting balloon angioplasty for treatment of in-stent restenosis.
    Zhou, Y
    Qu, D
    Liu, W
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (8A): : 17A - 17A