Conventional balloon angioplasty versus peripheral cutting balloon angioplasty for treatment of femoropopliteal artery in-stent restenosis: Initial experience

被引:132
|
作者
Dick, Petra [1 ]
Sabeti, Schila [1 ]
Mlekusch, Wolfgang [1 ]
Schlager, Oliver [1 ]
Amighi, Jasmin [1 ]
Haumer, Markus [1 ]
Cejna, Manfred [1 ]
Minar, Erich [1 ]
Schillinger, Martin [1 ]
机构
[1] Vienna Gen Hosp, Dept Internal Med 2, Div Angiol, Sch Med, A-1090 Vienna, Austria
关键词
D O I
10.1148/radiol.2481071159
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively determine whether cutting balloon angioplasty, when compared with conventional balloon angioplasty (CBA), improves morphologic and clinical outcome in patients with femoropopliteal in-stent restenosis. Materials and Methods: Patients with symptomatic femoropopliteal in-stent restenosis were randomly assigned to undergo CBA or peripheral cutting balloon angioplasty (PCBA) for treatment of lesions up to 20 cm in length. Patients were followed up clinically and with duplex ultrasonography (US) at 1, 3, and 6 months for occurrence of a restenosis of 50% or higher. The Fisher exact test and Mann Whitney U test were used for statistical analyses. Results: Forty patients were enrolled; one patient was lost to follow-up. In the remaining patients, CBA was performed in 22 patients; PCBA was used in 17 patients. Average lesion length was 80 mm +/- 68 (standard deviation). Restenosis rates at 6 months were 65% (11 of 17; 95% confidence interval: 42%, 88%) after PCBA versus 73% (16 of 22; 95% confidence interval: 54%, 92%) after CBA (P = .73). Ankle brachial index (0.83 vs 0.75, P = .26) and maximum walking capacity on the treadmill (117 m vs 103 m, P = .97) at 6 months were also not significantly different between the two groups. Conclusion: PCBA failed to prove superiority compared with CBA for treatment of femoropopliteal in-stent restenosis in this pilot study. In restenotic lesions with an average length of approximately 8 cm, both treatment modalities yielded disappointing 6-month patency rates.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [41] Mechanism of cutting balloon angioplasty for in-stent restenosis: An intravascular ultrasound study
    Montorsi, P
    Galli, S
    Fabbiocchi, F
    Loaldi, A
    Grancini, L
    Ravagnani, P
    Trabattoni, D
    Cozzi, S
    Grasselli, D
    Bartorelli, AL
    CIRCULATION, 2001, 104 (17) : 616 - +
  • [42] Mechanism of cutting balloon angioplasty for in-stent restenosis: An intravascular ultrasound study
    Montorsi, P
    Galli, S
    Fabbiocchi, F
    Loaldi, A
    Trabattoni, D
    Grancini, L
    Cozzi, S
    Ravagnani, P
    Parodi, O
    Bartorelli, AL
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (02) : 166 - 173
  • [43] Re: "Cutting Balloon Versus Conventional Balloon Angioplasty in Short Femoropopliteal Arterial Stenoses"
    Parmar, Vinay
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (05) : 628 - 629
  • [44] CONVENTIONAL BALLOON ANGIOPLASTY FOR FEMOROPOPLITEAL ARTERY OCCLUSIONS
    MORGENSTERN, BR
    GETRAJDMAN, GI
    LAFFEY, KJ
    BIXON, R
    MARTIN, EC
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 1991, 8 (02) : 145 - 154
  • [45] CONVENTIONAL BALLOON ANGIOPLASTY FOR FEMOROPOPLITEAL ARTERY OCCLUSIONS
    MORGENSTERN, BR
    GETRAJDMAN, GI
    LAFFEY, KJ
    BIXON, R
    MARTIN, EC
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 1990, 7 (02) : 159 - 168
  • [46] Cutting balloon angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis: multicenter registry in japan
    Nakamura, S
    Saito, E
    Miyauchi, T
    Yokoyama, J
    Kanazawa, A
    Hayama, Y
    Hozawa, K
    Nakamura, S
    Nakamura, H
    Yamamoto, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 36A - 37A
  • [47] BALLOON ANGIOPLASTY FOR TREATMENT OF IN-STENT RESTENOSIS - FEASIBILITY, SAFETY, AND EFFICACY
    MACANDER, PJ
    ROUBIN, GS
    AGRAWAL, SK
    CANNON, AD
    DEAN, LS
    BAXLEY, WA
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (02): : 125 - 131
  • [49] Peer review report 1 on "Paclitaxel-Coated Versus Uncoated Balloon Angioplasty for Femoropopliteal Artery In-Stent Restenosis"
    Baram, Aram
    INTERNATIONAL JOURNAL OF SURGERY, 2017, 37 : S316 - S316
  • [50] Percutaneous coronary balloon angioplasty for treatment of complex in-stent restenosis
    Salas, FN
    Romo, AI
    Polo, MC
    Alonso, LI
    Ibargollin, R
    REVISTA ESPANOLA DE CARDIOLOGIA, 1997, 50 (10): : 738 - 741