Validation of CT brain perfusion methods using a realistic dynamic head phantom

被引:39
|
作者
Riordan, Alan J. [1 ]
Prokop, Mathias [1 ,2 ]
Viergever, Max A. [1 ]
Dankbaar, Jan Willem [1 ]
Smit, Ewoud J. [1 ]
de Jong, Hugo W. A. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Radboud Univ Nijmegen, Dept Radiol, NL-6525 GA Nijmegen, Netherlands
关键词
CT perfusion; brain CT; phantom; SINGULAR-VALUE DECOMPOSITION; HUMAN CEREBRAL-CORTEX; ACUTE STROKE; BLOOD-FLOW; COMPUTED-TOMOGRAPHY; VOLUME; THRESHOLDS; HEMATOCRIT; SIMULATION; RESOLUTION;
D O I
10.1118/1.3592639
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Development and evaluation of a realistic hybrid head phantom for the validation of quantitative CT brain perfusion methods. Methods: A combination, or hybrid, of CT images of an anthropomorphic head phantom together with clinically acquired MRI brain images was used to construct a dynamic hybrid head phantom. Essential CT imaging parameters such as spatially dependent noise, effects of resolution, tube settings, and reconstruction parameters were intrinsically included by scanning a skull phantom using CT perfusion (CTP) protocols with varying mAs. These data were combined with processed high resolution 7T clinical MRI images to include healthy and diseased brain parenchyma, as well as the cerebral vascular system. Time attenuation curves emulating contrast bolus passage based on perfusion as observed in clinical studies were added. Using the phantom, CTP images were generated using three brain perfusion calculation methods: bcSVD, sSVD, and fit-based deconvolution, and the linearity and accuracy of the three calculation methods was assessed. Dependency of perfusion outcome on calculation method was compared to clinical data. Furthermore, the potential of the phantom to optimize brain perfusion packages was investigated. Results: All perfusion calculation methods showed overestimation of low perfusion values and underestimation of high perfusion values. Good correlation in behavior between phantom and clinical data was found (R-2 = 0.84). Conclusions: A dynamic hybrid head phantom constructed from CT and MRI data was demonstrated to realistically represent clinical CTP studies, which is useful for assessing CT brain perfusion acquisition, reconstruction, and analysis. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3592639]
引用
收藏
页码:3212 / 3221
页数:10
相关论文
共 50 条
  • [1] Development of a realistic, dynamic digital brain phantom for CT Perfusion validation
    Divel, Sarah E.
    Segars, W. Paul
    Christensen, Soren
    Wintermark, Max
    Lansberg, Maarten G.
    Pelc, Norbert J.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [2] Dynamic CT head phantom for perfusion and angiography studies
    Russell, K.
    Blazeski, A.
    Dannecker, K.
    Lee, Q. Y.
    Holscher, C.
    Donahue, C.
    van Kampen, W.
    MEDICAL IMAGING 2010: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2010, 7626
  • [3] A realistic Phantom of the head for the Validation of attenuation corrections methods in PET-MRI
    Harries, J.
    Jochimsen, T. H.
    Scholz, T.
    Schlender, T.
    Barthel, H.
    Sabri, O.
    Sattler, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S451 - S451
  • [4] Validation of Low Dose CT Perfusion Using Projection View Sharing On a CT Perfusion Phantom
    Martin, T.
    Wang, K.
    Bechwati, I.
    Wang, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E362 - E362
  • [5] Realistic Head Phantom for Evaluation of Brain Stroke Localization Methods Using 3D Printer
    Lee, Juneseok
    Bang, Jihoon
    Choi, Jaehoon
    JOURNAL OF ELECTROMAGNETIC ENGINEERING AND SCIENCE, 2016, 16 (04) : 254 - 258
  • [6] A realistic phantom of the human head for validation of attenuation correction methods in PET-MRI
    Harries, Johanna
    Jochimsen, Thies
    Scholz, Thomas
    Schlender, Tina
    Barthel, Henryk
    Sabri, Osama
    Sattler, Bernhard
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [7] Dynamic CT perfusion measurement in a cardiac phantom
    Ziemer, Benjamin P.
    Hubbard, Logan
    Lipinski, Jerry
    Molloi, Sabee
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (07): : 1451 - 1459
  • [8] Dynamic CT perfusion measurement in a cardiac phantom
    Benjamin P. Ziemer
    Logan Hubbard
    Jerry Lipinski
    Sabee Molloi
    The International Journal of Cardiovascular Imaging, 2015, 31 : 1451 - 1459
  • [9] Realistic head phantom to test microwave systems for brain imaging
    Mohammed, Beada'a J.
    Abbosh, Amin M.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2014, 56 (04) : 979 - 982
  • [10] Region of interest evaluation of SPECT image reconstruction methods using a realistic brain phantom
    Xia, WS
    Glick, SJ
    Pan, TS
    Soares, EJ
    Luo, DS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1336 - 1341