Electronic portal image assisted reduction of systematic set-up errors in head and neck irradiation

被引:97
|
作者
de Boer, HCJ
de Koste, JRV
Creutzberg, CL
Visser, AG
Levendag, PC
Heijmen, BJM
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Div Clin Phys, Dept Radiat Oncol, NL-3008 Rotterdam, Netherlands
[2] Univ Nijmegen, Joint Ctr Radiat Oncol Arnhem Nijmegen, Nijmegen, Netherlands
关键词
head and neck cancer; set-up verification; portal imaging; electronic portal imaging device;
D O I
10.1016/S0167-8140(01)00437-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify systematic and random patient set-up errors in head and neck irradiation and to investigate the impact of an off-line correction protocol on the systematic errors. Material and methods: Electronic portal images were obtained for 31 patients treated for primary supra-glottic larynx carcinoma who were immobilised using a polyvinyl chloride cast. The observed patient Set-Lip errors were input to the shrinking action level (SAL) off-line decision protocol and appropriate set-up corrections were applied. To assess the impact of the protocol, the positioning accuracy without application of set-up corrections was reconstructed. Results: The set-up errors obtained without set-up corrections (1 standard deviation (SD) = 1.5-2 mm for random and systematic errors) were comparable to those reported in other studies on similar fixation devices On an average, six fractions per patient were imaged and the set-up of half the patients was changed due to the decision protocol. Most changes were detected during weekly check measurements, not during the first days of treatment. The application of the SAL protocol reduced the width of the distribution of systematic errors to 1 mm (1 SD), as expected from simulations. A retrospective analysis Showed that this accuracy should be attainable with only two measurements per patient using a different off-line correction protocol, which does not apply action levels. Conclusions: Off-line verification protocols can be particularly effective in head and neck patients due to the smallness of the random setup errors. The excellent set-up reproducibility that can be achieved with such protocols enables accurate dose delivery in conformal treatments. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:299 / 308
页数:10
相关论文
共 50 条
  • [1] Evaluation of set-up errors in head and neck radiotherapy using electronic portal imaging
    Strbac, Bojan
    Jokic, Vesna Spasic
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (05): : 531 - 536
  • [2] Evaluation of set-up errors using electronic portal imaging in head and neck carcinoma
    Bayman, E.
    Uruk Ataman, O.
    Akman, F.
    Kynay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 82 : S35 - S35
  • [3] Evaluation of set-up errors using electronic portal imaging in head and neck carcinoma
    Ataman, Oe.
    Demirtas Bayman, E.
    Akman, F.
    Kinay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S306 - S306
  • [4] Interfractional set-up errors evaluation by daily electronic portal imaging of IMRT in head and neck cancer patients
    Pehlivan, Berrin
    Pichenot, Charlotte
    Castaing, Marine
    Auperin, Anne
    Lefkopoulos, Dimitri
    Arriagada, Rodrigo
    Bourhis, Jean
    [J]. ACTA ONCOLOGICA, 2009, 48 (03) : 440 - 445
  • [5] Image Guidance Derived Set-up Errors for Head and Neck IMRT Patients
    Richmond, N.
    Pilling, K.
    Thompson, E.
    Walker, C.
    Dunlop, P.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (03) : S50 - S51
  • [6] Analysis of set-up errors and assessment of adequate margins in head and neck tumors irradiation
    Morawska-Kaczynska, M.
    Skowronska-Gardas, A.
    Semaniak, A.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 94 - 94
  • [7] Systematic set-up errors for IMRT in the head and neck region: effect on dose distribution
    Samuelsson, A
    Mercke, C
    Johansson, KA
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 66 (03) : 303 - 311
  • [8] Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device
    Gupta, Tejpal
    Chopra, Supriya
    Kadam, Avinash
    Agarwal, Jai Prakash
    Devi, P. Reena
    Ghosh-Laskar, Sarbani
    Dinshaw, Ketayun Ardeshir
    [J]. RADIATION ONCOLOGY, 2007, 2 (1)
  • [9] Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device
    Tejpal Gupta
    Supriya Chopra
    Avinash Kadam
    Jai Prakash Agarwal
    P Reena Devi
    Sarbani Ghosh-Laskar
    Ketayun Ardeshir Dinshaw
    [J]. Radiation Oncology, 2
  • [10] Evaluation of set-up errors and determination of set-up margin in pelvic radiotherapy by electronic portal imaging device (EPID)
    Noghreiyan, Vajiheh Vejdani
    Nasseri, Shahrookh
    Anvari, Kazem
    Naji, Maryam
    Momennezhad, Mehdi
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 150 - 156