Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device

被引:29
|
作者
Gupta, Tejpal [1 ]
Chopra, Supriya [2 ]
Kadam, Avinash [1 ]
Agarwal, Jai Prakash [2 ]
Devi, P. Reena [1 ]
Ghosh-Laskar, Sarbani [2 ]
Dinshaw, Ketayun Ardeshir [2 ]
机构
[1] Tata Mem Hosp, ACTREC, Dept Radiat Oncol, Kharghar, Navi Mumbai, India
[2] Tata Mem Hosp, Dept Radiat Oncol, Bombay 400012, Maharashtra, India
关键词
D O I
10.1186/1748-717X-2-44
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Set-up errors are an inherent part of radiation treatment process. Coverage of target volume is a direct function of set-up margins, which should be optimized to prevent inadvertent irradiation of adjacent normal tissues. The aim of this study was to evaluate three-dimensional (3D) set-up errors and propose optimum margins for target volume coverage in head and neck radiotherapy. Methods: The dataset consisted of 93 pairs of orthogonal simulator and corresponding portal images on which 558 point positions were measured to calculate translational displacement in 25 patients undergoing conventional head and neck radiotherapy with antero-lateral wedge pair technique. Mean displacements, population systematic (Sigma) and random (sigma) errors and 3D vector of displacement was calculated. Set-up margins were calculated using published margin recipes. Results: The mean displacement in antero-posterior (AP), medio-lateral (ML) and supero-inferior (SI) direction was -0.25 mm (-6.50 to +7.70 mm), -0.48 mm (-5.50 to +7.80 mm) and +0.45 mm (-7.30 to +7.40 mm) respectively. Ninety three percent of the displacements were within 5 mm in all three cardinal directions. Population systematic (Sigma) and random errors (sigma) were 0.96, 0.98 and 1.20 mm and 1.94, 1.97 and 2.48 mm in AP, ML and SI direction respectively. The mean 3D vector of displacement was 3.84 cm. Using van Herk's formula, the clinical target volume to planning target volume margins were 3.76, 3.83 and 4.74 mm in AP, ML and SI direction respectively. Conclusion: The present study report compares well with published set-up error data relevant to head and neck radiotherapy practice. The set-up margins were < 5 mm in all directions. Caution is warranted against adopting generic margin recipes as different margin generating recipes lead to a different probability of target volume coverage.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device
    Tejpal Gupta
    Supriya Chopra
    Avinash Kadam
    Jai Prakash Agarwal
    P Reena Devi
    Sarbani Ghosh-Laskar
    Ketayun Ardeshir Dinshaw
    [J]. Radiation Oncology, 2
  • [2] Evaluation of set-up errors in head and neck radiotherapy using electronic portal imaging
    Strbac, Bojan
    Jokic, Vesna Spasic
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (05): : 531 - 536
  • [3] Evaluation of set-up errors using electronic portal imaging in head and neck carcinoma
    Bayman, E.
    Uruk Ataman, O.
    Akman, F.
    Kynay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 82 : S35 - S35
  • [4] Evaluation of set-up errors using electronic portal imaging in head and neck carcinoma
    Ataman, Oe.
    Demirtas Bayman, E.
    Akman, F.
    Kinay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S306 - S306
  • [5] Evaluation of Patient Set Up Errors in Head and Neck Three-Dimensional (3D) Conformal and Intensity-Modulated Radiotherapy Using Electronic Portal Imaging Device
    Farajollahi, Alireza
    Mohammadzadeh, Narjes
    Momennezhad, Mahdi
    Naseri, Shahrokh
    Mohebbi, Shokoufeh
    Shahedi, Fateme
    Mohebbi, Shadi
    [J]. Iranian Journal of Medical Physics, 2022, 19 (05) : 270 - 274
  • [6] Evaluation of set-up errors and determination of set-up margin in pelvic radiotherapy by electronic portal imaging device (EPID)
    Noghreiyan, Vajiheh Vejdani
    Nasseri, Shahrookh
    Anvari, Kazem
    Naji, Maryam
    Momennezhad, Mehdi
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 150 - 156
  • [7] Comparison of immobilisation, imaging and set-up errors during head and neck radiotherapy
    Hay, L.
    Devlin, L.
    Duffton, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2044 - S2045
  • [8] Interfractional set-up errors evaluation by daily electronic portal imaging of IMRT in head and neck cancer patients
    Pehlivan, Berrin
    Pichenot, Charlotte
    Castaing, Marine
    Auperin, Anne
    Lefkopoulos, Dimitri
    Arriagada, Rodrigo
    Bourhis, Jean
    [J]. ACTA ONCOLOGICA, 2009, 48 (03) : 440 - 445
  • [9] Electronic portal image assisted reduction of systematic set-up errors in head and neck irradiation
    de Boer, HCJ
    de Koste, JRV
    Creutzberg, CL
    Visser, AG
    Levendag, PC
    Heijmen, BJM
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 61 (03) : 299 - 308
  • [10] Set-up errors in radiotherapy for oesophageal cancers - Is electronic portal imaging or conebeam more accurate?
    Hawkins, Maria A.
    Aitken, Alexandra
    Hansen, Vibeke N.
    McNair, Helen A.
    Tait, Diana M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 98 (02) : 249 - 254