A Novel Amperometric Biosensor Based on Poly(allylamine hydrochloride) for Determination of Ethanol in Beverages

被引:9
|
作者
Istrate, Oana Maria [1 ]
Rotariu, Lucian [1 ,2 ]
Bala, Camelia [1 ,2 ]
机构
[1] Univ Bucharest, LaborQ, Bucharest 030018, Romania
[2] Univ Bucharest, Dept Analyt Chem, Bucharest 030018, Romania
关键词
alcohol dehydrogenase; biosensor; screen-printed electrode; ethanol; PRINTED CARBON ELECTRODE; ALCOHOL-DEHYDROGENASE; CONDUCTING POLYMER; MASS-SPECTROMETRY; NADH; IMMOBILIZATION; FERMENTATION; GASOLINE;
D O I
10.3390/s21196510
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, we report on a new type of ethanol biosensor based on a screen-printed electrode modified with poly(allylamine hydrochloride). The alcohol dehydrogenase was immobilized on the surface of the sensor using the sol-gel matrix. Working parameters such as applied potential, pH, NAD(+) concentration, storage conditions were optimized. A response range between 0.05 and 2 mM was found with a sensitivity of 13.45 & PLUSMN; 0.67 mu A/mM & BULL;cm(2) and a detection limit of 20 mu M. The developed biosensor was used to detect ethanol in commercial beverages with good accuracy.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Simple and Rapid Determination of Ethanol Content in Beer Using an Amperometric Biosensor
    Polan, Vojtech
    Eisner, Ales
    Vytras, Karel
    CHEMOSENSORS, 2015, 3 (02): : 169 - 177
  • [22] An amperometric microbial biosensor development based on Candida tropicalis yeast cells for sensitive determination of ethanol
    Akyilmaz, E
    Dinçkaya, E
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (07): : 1263 - 1269
  • [23] Ethanol Determination in Alcoholic Beverages Using Two Different Amperometric Enzyme Sensors
    Angeloni, Riccardo
    Tomassetti, Mauro
    Castrucci, Mauro
    Campanella, Luigi
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (01) : 56 - 67
  • [24] Sensitivity Enhancement of a Humidity Sensor Based on poly(sodium phosphate) and poly(allylamine hydrochloride)
    Hernaez, Miguel
    Lopez-Torres, Diego
    Elosua, Cesar
    Matias, Ignacio R.
    Arregui, Francisco J.
    2013 IEEE SENSORS, 2013, : 1669 - 1672
  • [25] Tuning the Surface Properties of Poly(Allylamine Hydrochloride)-Based Multilayer Films
    Ciejka, Justyna
    Grzybala, Michal
    Gut, Arkadiusz
    Szuwarzynski, Michal
    Pyrc, Krzysztof
    Nowakowska, Maria
    Szczubialka, Krzysztof
    MATERIALS, 2021, 14 (09)
  • [26] A novel amperometric phenol biosensor based on immobilized HRP on poly(glycidylmethacrylate)-grafted iron oxide nanoparticles for the determination of phenol derivatives
    Cevik, Emre
    Senel, Mehmet
    Baykal, Abdulhadi
    Abasiyanik, M. Fatih
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 396 - 405
  • [27] Simultaneous Voltammetric Determination of Ascorbic Acid and Sulfite in Beverages Employing a Glassy Carbon Electrode Modified with Carbon Nanotubes within a Poly(Allylamine Hydrochloride) Film
    Sartori, Elen Romao
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2012, 24 (03) : 627 - 634
  • [28] A novel combined thermometric and amperometric biosensor for lactose determination based on immobilised cellobiose dehydrogenase
    Yakovleva, Maria
    Buzas, Orsolya
    Matsumura, Hirotoshi
    Samejima, Masahiro
    Igarashi, Kiyohiko
    Larsson, Per-Olof
    Gorton, Lo
    Danielsson, Bengt
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 251 - 256
  • [29] A novel disposable amperometric biosensor based on trienzyme electrode for the determination of total creatine kinase
    Liu, Chun-Xiu
    Jiang, Li-Ying
    Wang, Hui
    Guo, Zong-Hui
    Cai, Xin-Xia
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) : 295 - 300
  • [30] A nylon membrane based amperometric biosensor for polyphenol determination
    Narang, Jagriti
    Chauhan, Nidhi
    Singh, Anamika
    Pundir, C. S.
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2011, 72 (3-4) : 276 - 281