Test of 24 strip line radiation detector based on semi-insulating GaAs using X-ray source

被引:0
|
作者
Zat'ko, B [1 ]
Dubecky, F [1 ]
Perd'ochová, A [1 ]
Scepko, P [1 ]
Melov, V [1 ]
Skriniarová, J [1 ]
Haupt, L [1 ]
机构
[1] Slovak Acad Sci, Inst Elect Engn, SK-84104 Bratislava, Slovakia
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Line detector with 32-strips based on semi-insulating GaAs is fabricated. Analog and digital read-out electronic chain with 24 read-out channels with the strip line detector is connected. The progressive SMD technology with automatic assembling of electronic devices for readout front-end electronic is used Testing of counting ability of each strip with micro collimated X-ray source up to 60 kV is carried out. The cross talk between neighbouring strips is analyzed.
引用
收藏
页码:243 / 246
页数:4
相关论文
共 50 条
  • [31] Response of semi-insulating 100 μm thick GaAs detector for α-particles, γ-rays and X-rays
    Kordyasz, AJ
    Strzelecka, SG
    Kownacki, J
    Dobrzanski, L
    Hruban, A
    Orlowski, W
    Wegner, E
    Reissig, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (03): : 716 - 720
  • [32] Role of minority carrier extraction in performance of radiation detectors based on semi-insulating GaAs
    Dubecky, F
    Zat'ko, B
    Necas, V
    Sekácová, M
    Huran, J
    Bohácek, P
    Ferrari, C
    Kordos, P
    Förster, A
    ASDAM '02, CONFERENCE PROCEEDINGS, 2002, : 145 - 148
  • [33] An exploration of the semi-insulating GaAs-based particle detector at temperatures below 300 K
    Darmo, J
    Dubecky, F
    Zat'ko, B
    Necas, V
    Pelfer, PG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 437 - 440
  • [34] The semi-insulating GaAs-based particle detector at IEE SAS:: first imaging results
    Darmo, J
    Dubecky, F
    Zat'ko, B
    Bohácek, P
    Sekácová, M
    Kvitkovic, J
    Necas, V
    Pelfer, PG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 418 - 421
  • [35] X- and gamma-ray detectors based on bulk semi-insulating GaAs & InP:: Present status and prospects
    Dubecky, F
    Darmo, J
    Zat'ko, B
    Fornari, R
    Necas, V
    Krempasky, M
    Pelfer, PG
    Sekácová, M
    Bohácek, P
    SIMC-XI: 2000 INTERNATIONAL SEMICONDUCTING AND INSULATING MATERIALS CONFERENCE, PROCEEDINGS, 2000, : 151 - 158
  • [36] Simulation of polarization dynamics in semi-insulating, Cr-compensated GaAs pixelated sensors under high x-ray fluxes
    Zambon, P.
    AIP ADVANCES, 2021, 11 (07)
  • [37] On the detection performance of semi-insulating GaAs detectors coupled to multichannel ASIC DX64 for X-ray imaging applications
    Zat'ko, Bohumir
    Dubecky, Frantisek
    Scepko, Pavol
    Grybos, Pawel
    Mudron, Jan
    Maj, Piotr
    Szczygiel, Robert
    Frollo, Ivan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 101 - 104
  • [38] Electrical and detection performance of radiation detector based on bulk semi-insulating InP: Fe:: Role of detector volume
    Zat'ko, B
    Dubecky, F
    Darmo, J
    Euthymiou, P
    Necas, V
    Krempasky, M
    Sekácová, M
    Korytár, D
    Csabay, O
    Harmatha, L
    Pelfer, PG
    ASDAM 2000: THIRD INTERNATIONAL EUROCONFERENCE ON ADVANCED SEMICONDUCTOR DEVICES AND MICROSYSTEMS - CONFERENCE PROCEEDINGS, 2000, : 429 - 432
  • [39] X-ray imaging using a pixel GaAs detector
    Nucl Instrum Methods Phys Res Sect A, 2-3 (547):
  • [40] X-ray imaging using a tunable coherent X-ray source based on parametric X-ray radiation
    Hayakawa, Y.
    Takahashi, Y.
    Kuwada, T.
    Sakae, T.
    Tanaka, T.
    Nakao, K.
    Nogami, K.
    Inagaki, M.
    Hayakawa, K.
    Sato, I.
    JOURNAL OF INSTRUMENTATION, 2013, 8