Test of 24 strip line radiation detector based on semi-insulating GaAs using X-ray source

被引:0
|
作者
Zat'ko, B [1 ]
Dubecky, F [1 ]
Perd'ochová, A [1 ]
Scepko, P [1 ]
Melov, V [1 ]
Skriniarová, J [1 ]
Haupt, L [1 ]
机构
[1] Slovak Acad Sci, Inst Elect Engn, SK-84104 Bratislava, Slovakia
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Line detector with 32-strips based on semi-insulating GaAs is fabricated. Analog and digital read-out electronic chain with 24 read-out channels with the strip line detector is connected. The progressive SMD technology with automatic assembling of electronic devices for readout front-end electronic is used Testing of counting ability of each strip with micro collimated X-ray source up to 60 kV is carried out. The cross talk between neighbouring strips is analyzed.
引用
收藏
页码:243 / 246
页数:4
相关论文
共 50 条
  • [21] Technology and Performance Study of a Two-Line Monolithic X- and γ-Ray Detection Chip Based on Semi-Insulating GaAs
    Bohacek, P.
    Dubecky, F.
    Zat'ko, B.
    Sekacova, M.
    Huran, J.
    Necas, V.
    Mudron, J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (06) : 3354 - 3358
  • [22] The X-ray sensitivity of semi-insulating polycrystalline CdZnTe thick films
    Won, Jae Ho
    Kim, Ki Hyun
    Suh, Jong Hee
    Cho, Shin Hang
    Cho, Pyong Kon
    Hong, Jin Ki
    Kim, Sun Ung
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 206 - 208
  • [23] Performance of a Schottky surface barrier radiation detector based on bulk undoped semi-insulating GaAs at reduced temperature
    Zat'ko, B
    Dubecky, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (02) : 625 - 629
  • [24] Digital X-ray portable scanner based on monolithic semi-insulating GaAs detectors:: General description and first "quantum" images
    Dubecky, F
    Perd'ochová, A
    Scepko, P
    Zat'ko, B
    Sekerka, V
    Necas, V
    Sekácová, M
    Hudec, M
    Bohácek, P
    Huran, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 118 - 124
  • [25] Role of electrode technology in radiation detector based on semi-insulating InP in development of detector array
    Dubecky, F
    Bohácek, P
    Zatko, B
    Sekácová, M
    Huran, J
    Smatko, V
    Fornari, R
    Gombia, E
    Mosca, R
    Pelfer, PG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 181 - 191
  • [26] THE DISTRIBUTION OF LATTICE STRAIN AND TILT IN LEC SEMI-INSULATING GAAS MEASURED BY DOUBLE CRYSTAL X-RAY TOPOGRAPHY
    BARNETT, SJ
    BROWN, GT
    TANNER, BK
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1987, (87): : 615 - 620
  • [27] Detection of fast neutrons using detectors based on semi-insulating GaAs
    Zat'ko, B.
    Sedlackova, K.
    Dubecky, F.
    Bohacek, P.
    Sekacova, M.
    Necas, V.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [28] Electrical Properties and X-ray Sensitivity of Semi-insulating CdZnTe:Pb Crystals
    Won, J. H.
    Cho, S. H.
    Suh, J. H.
    Kim, K. H.
    Hong, J. K.
    Kim, S. U.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3660 - 3663
  • [29] Electrical properties and X-ray spectrum of semi-insulating CdZnTe:Pb crystals
    Won, J. H.
    Kim, K. H.
    Cho, S. H.
    Suh, J. H.
    Hong, J. K.
    Kim, S. U.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02): : 211 - 214
  • [30] X-RAY AND SEM INVESTIGATION OF CRYSTAL DEFECTS IN N-TYPE, P-TYPE AND SEMI-INSULATING GAAS
    FRANZOSI, P
    SALVIATI, G
    ACTA PHYSICA HUNGARICA, 1985, 57 (3-4) : 251 - 261