Impact of electrospray ion source platforms on matrix effect due to plasma phospholipids in the determination of rivastigmine by LC-MS/MS

被引:8
|
作者
Trivedi, Vikas [1 ]
Upadhyay, Vivek [1 ]
Yadav, Manish [2 ]
Shrivastav, Pranav S. [3 ]
Sanyal, Mallika [1 ,4 ]
机构
[1] Kadi Sarva Vishwavidyalaya, Dept Chem, Sect 15-23, Gandhinagar 382015, India
[2] Alkem Labs Ltd, Bioanalyt Dept, Bombay 400013, Maharashtra, India
[3] Gujarat Univ, Sch Sci, Dept Chem, Ahmadabad 380009, Gujarat, India
[4] St Xaviers Coll, Dept Chem, Ahmadabad 380009, Gujarat, India
关键词
LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; MAJOR METABOLITE; SOURCE DESIGN; NAP; 226-90; ELIMINATION; SUPPRESSION; LC/MS/MS; ELUTION; SAMPLES;
D O I
10.4155/bio.14.85
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: This study evaluates the performance of three electrospray ionization source designs to monitor the interference of plasma phospholipids for reliable estimation of rivastigmine by LC-MS/MS for method ruggedness. The variation in the area response due to matrix effects was assessed by post-column infusion, post-extraction spiking and standard-line slope methods. Results: The observed interference due to coeluting phospholipids (m/z: 524.0/184.0) at the retention time of rivastigmine was 39.5, 12.9 and 0.4% using angular spray, orthogonal spray and dual orthogonal ion source spray design, respectively. Similarly, %CV for standard line slopes was 6.9, 4.6 and 2.0, respectively. Conclusion: Z-spray source design provided better and efficient transfer of gas phase ions into the mass analyzer compared with angular and orthogonal spray. The study showed that Z-spray ion source provided minimum interference from phospholipids compared with other ion source designs.
引用
收藏
页码:2301 / 2316
页数:16
相关论文
共 50 条
  • [1] In electrospray ionization source hydrogen/deuterium exchange LC-MS and LC-MS/MS for characterization of metabolites
    Lam, W
    Ramanathan, R
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (04) : 345 - 353
  • [2] Quantitation of melatonin and n-acetylserotonin in human plasma by nanoflow LC-MS/MS and electrospray LC-MS/MS
    Carter, Melissa D.
    Calcutt, M. Wade
    Malow, Beth A.
    Rose, Kristie L.
    Hachey, David L.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (03): : 277 - 285
  • [3] Systematic evaluation of plasma phospholipids for reliable and precise determination of dronedarone and desbutyldronedarone by LC-MS/MS
    Parekh, Jignesh M.
    Sanyal, Mallika
    Yadav, Manish
    Shrivastav, Pranav S.
    BIOANALYSIS, 2014, 6 (19) : 2635 - 2650
  • [4] LC-MS–MS Determination of Pregabalin in Human Plasma
    Vikas V. Vaidya
    Santosh M. Yetal
    Shikha M. N. Roy
    Noel A. Gomes
    Santosh S. Joshi
    Chromatographia, 2007, 66 : 925 - 928
  • [5] Determination of Meropenem in Rabbit Plasma by LC-MS/MS
    Lin, Guanyang
    Zhang, Haiyan
    Xue, Feng
    Li, Wenjuan
    Liu, Naihua
    Chen, Lianguo
    Wang, Xianqin
    Xu, Renai
    Ma, Jianshe
    LATIN AMERICAN JOURNAL OF PHARMACY, 2011, 30 (10): : 1895 - 1900
  • [6] Determination of lercanidipine in human plasma by LC-MS/MS
    Jang, Moon-Sun
    La, Sookie
    Chang, Kyu Young
    Kang, Seung Woo
    Han, Sang Beom
    Lee, Kyung Ryul
    Lee, Hee Joo
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2008, 21 (01): : 34 - 40
  • [7] Determination of pethidine in human plasma by LC-MS/MS
    Wang, Xianqin
    Xiang, Zheng
    Cai, Xiaojun
    Wu, Haiya
    Wang, Xuebao
    Li, Junwei
    Zhang, Meiling
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (07) : 833 - 837
  • [8] Determination of Ribavirin in Human Plasma by LC-MS/MS
    Ostervall, J.
    Ostlund, A.
    Pohanka, A.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 725 - 725
  • [9] Validation of the LC-MS/MS method for the quantification of mevalonic acid in human plasma and determination of the matrix effect
    Saini, G. S.
    Wani, T. A.
    Gautam, A.
    Varshney, B.
    Ahmed, T.
    Rajan, K. S.
    Pillai, K. K.
    Paliwal, J. K.
    JOURNAL OF LIPID RESEARCH, 2006, 47 (10) : 2340 - 2345
  • [10] Elimination of LC-MS/MS matrix effect due to phospholipids using specific solid-phase extraction elution conditions
    Lahaie, Mathieu
    Mess, Jean-Nicholas
    Furtado, Milton
    Garofolo, Fabio
    BIOANALYSIS, 2010, 2 (06) : 1011 - 1021