Potentiometric Screen-Printed Bisensor for Simultaneous Determination of Chromium(III) and Chromium(VI)

被引:15
|
作者
Sanchez-Moreno, Raul A. [1 ]
Jesus Gismera, Ma [1 ]
Teresa Sevilla, Ma [1 ]
Procopio, Jesus R. [1 ]
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain
关键词
Chromium; Screen-printed electrode; Graphite-epoxy composite; Flow-injection potentiometry; Potentiometry; SIMULTANEOUS QUANTIFICATION; MEMBRANE SENSORS; ELECTRODES; SPECIATION; BATCH;
D O I
10.1002/elan.201000437
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable dual screen-printed electrode was designed and evaluated for the direct and simultaneous determination of chromium(VI) and chromium(III) in batch and flow analysis. For this purpose a carbon screen-printed bielectrode was modified with a graphite-epoxy composite which contains diphenylcarbazide and another graphiteepoxy composite prepared with di(2-hydroxyphenylimino) ethane. The principal analytical parameters of the potentiometric responses in batch and flow analysis were optimized and calculated. The bisensor shows optimal detection limits of 7.7 x 10(-7) M and 7.9 x 10(-6) M in static mode, and 9.0 x 10(-7) M and 1.2 x 10(-5) M in flow analysis for hexavalent and trivalent chromium, respectively. This potentiometric device was employed with successful results to determine both chromium species in leachates from municipal solid waste landfills.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 50 条
  • [1] Screen-printed sensor for batch and flow injection potentiometric chromium(VI) monitoring
    Raúl A. Sánchez-Moreno
    M. Jesús Gismera
    M. Teresa Sevilla
    Jesús R. Procopio
    [J]. Analytical and Bioanalytical Chemistry, 2010, 397 : 331 - 338
  • [2] Screen-printed sensor for batch and flow injection potentiometric chromium(VI) monitoring
    Sanchez-Moreno, Raul A.
    Jesus Gismera, M.
    Teresa Sevilla, M.
    Procopio, Jesus R.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (01) : 331 - 338
  • [3] Simultaneous Determination of Chromium(VI) and Chromium(III) by Capillary Electrophoresis
    Sadayuki Himeno
    Yoichi Nakashima
    Ken-ichi Sano
    [J]. Analytical Sciences, 1998, 14 : 369 - 373
  • [4] Simultaneous determination of chromium(VI) and chromium(III) by capillary electrophoresis
    Himeno, S
    Nakashima, Y
    Sano, K
    [J]. ANALYTICAL SCIENCES, 1998, 14 (02) : 369 - 373
  • [5] Sequential determination of chromium(VI) and chromium(III) by potentiometric flow-injection method
    Ohura, H
    Imato, T
    Matsuo, I
    Yamasaki, S
    [J]. BUNSEKI KAGAKU, 2000, 49 (01) : 59 - 64
  • [6] The solid potentiometric electrode for determination of chromium (III, VI) ions
    Amerkhanova, Sh. K.
    [J]. BULLETIN OF THE UNIVERSITY OF KARAGANDA-CHEMISTRY, 2013, (69): : 29 - 33
  • [7] Electrochemical determination of chromium(VI) using metallic nanoparticle-modified carbon screen-printed electrodes
    Dominguez-Renedo, Olga
    Ruiz-Espelt, Laura
    Garcia-Astorgano, Natalia
    Julia Arcos-Martinez, M.
    [J]. TALANTA, 2008, 76 (04) : 854 - 858
  • [8] Screen-printed electrodes for electroanalytical sensing, of chromium VI in strong acid media
    Miscoria, S. A.
    Jacq, C.
    Maeder, T.
    Martin Negri, R.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 294 - 302
  • [9] SIMULTANEOUS AND SEQUENTIAL DETERMINATION OF CHROMIUM(VI) AND CHROMIUM(III) BY UNSEGMENTED FLOW METHODS
    RUZ, J
    RIOS, A
    DECASTRO, MDL
    VALCARCEL, M
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (05): : 499 - 502
  • [10] Screen-printed electrochemical chromium (VI) sensing electrodes for effluent bioremediation monitoring
    Maeder, T.
    Miscoria, S.
    Jacq, C.
    Ryser, P.
    Martin Negri, R.
    [J]. 26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1303 - 1306