Screen-printed electrodes for electroanalytical sensing, of chromium VI in strong acid media

被引:52
|
作者
Miscoria, S. A. [1 ,2 ]
Jacq, C. [3 ]
Maeder, T. [3 ]
Martin Negri, R. [1 ]
机构
[1] Univ Buenos Aires, Fac Ciencias Exactas & Nat, DQIAyQF, Inst Quim Fis Mat Medio Ambiente & Energia INQUIM, Buenos Aires, DF, Argentina
[2] Univ Nacl Patagonia San Juan Bosco, Fac Ciencias Nat, Dept Quim, Comodoro Rivadavia, Chubut, Argentina
[3] Ecole Polytech Fed Lausanne, LPM, CH-1015 Lausanne, Switzerland
来源
关键词
Electrochemical sensors; Hexavalent chromium; Screen-printed electrodes; Thick-film technology; UPHILL PERMEATION; CARBON NANOTUBES; NATURAL-WATERS; SPECIATION; CR(VI); SAMPLES; SYSTEM; DIPHENYLCARBAZIDE; CHROMATOGRAPHY; REDUCTION;
D O I
10.1016/j.snb.2014.01.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simple, low-cost and acid-resistant carbon-based screen-printed electrodes (SPEs) addressed to detection of hexavalent chromium species, Cr(VI), in sulfuric acid at pH about 1, were prepared and characterized. Working and counter electrodes were prepared jointly on the same substrate in a single strip (working-counter electrodes pair). The batch printing process allowed obtaining many working-counter electrode pairs in a unique step. The developed working electrodes are comprised of several layers deposited on an alumina substrate: (1) bottom silver conductor, (2) dense organic-graphite composite conductor, (3) active layer consisting of a porous organic-graphite composite which contains a Cr(III) ionophore for testing Cr(III) obtained after reducing Cr(VI), and (4) an insulating and protective dielectric. All materials except the bottom Ag conductor were made on an organic matrix based on a thermoplastic polymer, polyvinylbutyral (PVB). The amperometric determination of Cr(VI) species at pH 1 was performed over a wide concentration range (dynamic range 3 mu M-40 mM). The range for linear amperometric response is 3 mu M-10mM, with sensitivity about 0.08 mAmM(-1). The sensitivity is improved in comparison with previously developed sensors, while keeping a low limit of detection (LOD about 1 mu M). The response of the sensors are not interfered by the presence of Cr(III) in the solution, although the sensor can detect local formation of Cr(III) at the electrode surface after the reduction of Cr(VI) when diethylenetriaminepentaacetic acid (DTPA), a complexing agent for Cr(III) is incorporated into the pastes. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:294 / 302
页数:9
相关论文
共 50 条
  • [1] Electroanalytical sensing of chromium(III) and (VI) utilising gold screen printed macro electrodes
    Metters, Jonathan P.
    Kadara, Rashid O.
    Banks, Craig E.
    [J]. ANALYST, 2012, 137 (04) : 896 - 902
  • [2] Screen-printed electrochemical chromium (VI) sensing electrodes for effluent bioremediation monitoring
    Maeder, T.
    Miscoria, S.
    Jacq, C.
    Ryser, P.
    Martin Negri, R.
    [J]. 26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1303 - 1306
  • [3] Utilising copper screen-printed electrodes (CuSPE) for the electroanalytical sensing of sulfide
    Thakur, Bhawana
    Bernalte, Elena
    Smith, Jamie P.
    Foster, Christopher W.
    Linton, Patricia E.
    Sawant, Shilpa N.
    Banks, Craig E.
    [J]. ANALYST, 2016, 141 (04) : 1233 - 1238
  • [4] Graphite screen printed electrodes for the electrochemical sensing of chromium(VI)
    Hallam, Philip M.
    Kampouris, Dimitrios K.
    Kadara, Rashid O.
    Banks, Craig E.
    [J]. ANALYST, 2010, 135 (08) : 1947 - 1952
  • [5] Graphene Quantum Dots Modified Screen-printed Electrodes as Electroanalytical Sensing Platform for Diethylstilbestrol
    Gevaerd, Ava
    Banks, Craig E.
    Bergamini, Marcio F.
    Marcolino-Junior, Luiz Humberto
    [J]. ELECTROANALYSIS, 2019, 31 (05) : 838 - 843
  • [6] Electroanalytical Overview: Screen-Printed Electrochemical Sensing Platforms
    Crapnell, Robert D.
    Banks, Craig E.
    [J]. CHEMELECTROCHEM, 2024,
  • [7] Ultraflexible Screen-Printed Graphitic Electroanalytical Sensing Platforms
    Foster, Christopher W.
    Metters, Jonathan P.
    Kampouris, Dimitrios K.
    Banks, Craig E.
    [J]. ELECTROANALYSIS, 2014, 26 (02) : 262 - 274
  • [8] Carbon Black-Modified Screen-Printed Electrodes as Electroanalytical Tools
    Arduini, Fabiana
    Di Nardo, Fabio
    Amine, Aziz
    Micheli, Laura
    Palleschi, Giuseppe
    Moscone, Danila
    [J]. ELECTROANALYSIS, 2012, 24 (04) : 743 - 751
  • [9] Graphene Oxide Bulk-Modified Screen-Printed Electrodes Provide Beneficial Electroanalytical Sensing Capabilities
    Rowley-Neale, Samuel J.
    Brownson, Dale A. C.
    Smith, Graham
    Banks, Craig E.
    [J]. BIOSENSORS-BASEL, 2020, 10 (03):
  • [10] Electroanalytical Sensing of Flunitrazepam Based on Screen Printed Graphene Electrodes
    Garcia-Gutierrez, Enriqueta
    Lledo-Fernandez, Carlos
    [J]. CHEMOSENSORS, 2013, 1 (03) : 68 - 77