Screen-printed sensor for batch and flow injection potentiometric chromium(VI) monitoring

被引:14
|
作者
Sanchez-Moreno, Raul A. [1 ]
Jesus Gismera, M. [1 ]
Teresa Sevilla, M. [1 ]
Procopio, Jesus R. [1 ]
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain
关键词
Chromium(VI); Screen-printed electrode; Graphite-epoxy composite; Diphenylcarbohydrazide; Flow-injection potentiometry; Potentiometry; ION-SELECTIVE ELECTRODES; MEMBRANE SENSOR; ELECTROCHEMICAL SENSORS; COMPOSITE; CARBON;
D O I
10.1007/s00216-009-3437-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A disposable screen-printed electrode was designed and evaluated for direct detection of chromium(VI) in batch and flow analysis. The carbon screen-printed electrode was modified with a graphite-epoxy composite. The optimal graphite-epoxy matrix contains 37.5% graphite powder, 12.5% diphenylcarbohydrazide, a selective compound for chromium(VI), and 50% epoxy resin. The principal analytical parameters of the potentiometric response in batch and flow analysis were optimized and calculated. The screen-printed sensor exhibits a response time of 20 +/- 1 s. In flow analysis, the analytical frequency of sampling is 70 injections per hour using 0.1 M NaNO3 solution at pH 3 as the carrier, a flow rate of 2.5 mL.min(-1), and an injection sample volume of 0.50 mL. The sensor shows potentiometric responses that are very selective for chromium(VI) ions and optimal detection limits in both static mode (2.1 x 10(-7) M) and online analysis (9.4 x 10(-7) M). The disposable potentiometric sensor was employed to determine toxicity levels of chromium(VI) in mineral, tap, and river waters by flow-injection potentiometry and batch potentiometry. Chromium(VI) determination was also carried out with successful results in leachates from municipal solid waste landfills.
引用
收藏
页码:331 / 338
页数:8
相关论文
共 50 条
  • [1] Screen-printed sensor for batch and flow injection potentiometric chromium(VI) monitoring
    Raúl A. Sánchez-Moreno
    M. Jesús Gismera
    M. Teresa Sevilla
    Jesús R. Procopio
    [J]. Analytical and Bioanalytical Chemistry, 2010, 397 : 331 - 338
  • [2] Potentiometric Screen-Printed Bisensor for Simultaneous Determination of Chromium(III) and Chromium(VI)
    Sanchez-Moreno, Raul A.
    Jesus Gismera, Ma
    Teresa Sevilla, Ma
    Procopio, Jesus R.
    [J]. ELECTROANALYSIS, 2011, 23 (01) : 287 - 294
  • [3] Screen-printed electrochemical chromium (VI) sensing electrodes for effluent bioremediation monitoring
    Maeder, T.
    Miscoria, S.
    Jacq, C.
    Ryser, P.
    Martin Negri, R.
    [J]. 26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1303 - 1306
  • [4] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    El-Attar, Rehab O.
    Hendawy, Hassan A. M.
    Khaled, Elmorsy
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (11) : 3019 - 3029
  • [5] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    Rehab O. El-Attar
    Hassan A. M. Hendawy
    Elmorsy Khaled
    [J]. Journal of the Iranian Chemical Society, 2020, 17 : 3019 - 3029
  • [6] A screen-printed flexible flow sensor
    Moschos, A.
    Syrovy, T.
    Syrova, L.
    Kaltsas, G.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (05)
  • [7] A new modified screen-printed sensor for monitoring of ultratrace concentrations of Mo(VI)
    Jedruchniewicz, Katarzyna
    Tyszczuk-Rotko, Katarzyna
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 847
  • [8] Novel Green Screen-Printed Potentiometric Sensor for Monitoring Antihistamine Drug Chlorphenoxamine HCl in Various Matrices
    Ashraf, Ahmed
    El-Zeany, Badr A.
    Sedik, Ghada A.
    Rostom, Yasmin
    ElDin, Norhan Badr
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (07)
  • [9] Screen-printed reference electrodes for potentiometric measurements
    Tymecki, L
    Zwierkowska, Z
    Koncki, R
    [J]. ANALYTICA CHIMICA ACTA, 2004, 526 (01) : 3 - 11
  • [10] Novel naproxenate screen-printed potentiometric sensors
    Khaled, Elmorsy
    Shoukry, Eman M.
    Amin, Mona F.
    Said, Basmat A. M.
    Abd-Elmonem, Mahmmoud S.
    [J]. EGYPTIAN PHARMACEUTICAL JOURNAL, 2018, 17 (03) : 201 - 211