Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

被引:0
|
作者
Taeubner, Angelika
Bruns, Thomas
机构
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison CCAUV.V-S1 was organized to compare measurements of sinusoidal angular accelerations in the frequency range from 0.4 Hz to 1 kHz. This was a bilateral comparison between the Korea Research Institute of Standards and Science (KRISS), Republic of Korea, and the Physikalisch-Technische Bundesanstalt (PTB), Germany. Both NMIs applied laser interferometry in compliance with ISO 16063-15:2006 "Methods for the calibration of vibration and shock transducers - Part 15: Primary angular vibration calibration by laser interferometry". The complex voltage sensitivity (magnitude and phase) of one angular transfer standard in the frequency range of 0.4 Hz to 100 Hz and the complex charge sensitivity (magnitude and phase) of one angular reference standard in the frequency range of 1 Hz to 1000 Hz were measured.
引用
收藏
页数:53
相关论文
共 50 条
  • [11] Final report on supplementary comparison SADCMET.AUV.V-S1
    Veldman, Ian
    von Martens, Hans-Juergen
    METROLOGIA, 2004, 41
  • [12] Final Report on Supplementary Comparison APMP.AUV.V-S1
    Sun, Qiao
    Veldman, Ian
    METROLOGIA, 2013, 50
  • [13] The methods for the calibration of vibration pick-ups by laser interferometry: part V. Uncertainty evaluation on the ratio of transducer's peak output value to peak input acceleration in shock calibration
    Nozato, H.
    Oota, A.
    Ishigami, T.
    Usuda, T.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (12)
  • [14] International key comparison APMP.QM-S1: Comparison of primary standards of nitrogen in helium
    Botha, Angelique
    Smeulders, Damian
    Kato, Kenji
    Oh, Sang
    Kim, Byung
    METROLOGIA, 2010, 47
  • [15] New physics in (b)over-bar → (s)over-bar transitions and the Bd,s0 → V1V2 angular analysis
    Datta, Alakabha
    Duraisamy, Murugeswaran
    London, David
    PHYSICAL REVIEW D, 2012, 86 (07)
  • [16] SIMMF-S1 TESTING MACHINE CALIBRATION IN COMPRESSION SIM COMPARISON UP TO 100 kN
    Villarroel Poblete, Juan Christian
    Oliva C, Hernan
    Soto Pinto, Luis Ruben
    Haucke, Guenther
    METROLOGIA, 2014, 51
  • [17] Supplementary comparison on 1,018 V and 10 V voltage standards (COOMET.EM-S20)
    Straistari, S.
    Schumacher, Bernhard
    METROLOGIA, 2019, 56 (1A)
  • [18] Bilateral comparison EURAMETMP-S10 Final report Calibration of a SRG between 0.005 Pa and 1 Pa, and of a CDG between 0.5 Pa and 100 Pa 2010-2011
    Medina, Nieves
    METROLOGIA, 2011, 48
  • [19] Bilateral comparison of 1 V and 10 V standards between the DMDM (Serbia) and the BIPM, January to March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Pantelic-Babic, J.
    Sofranac, Z.
    Zivkovic, V.
    METROLOGIA, 2015, 52
  • [20] Bilateral Comparison of 1 V and 10 V Standards between the INM (Romania) and the BIPM, August to October 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Simionescu, M.
    Cirneanu, L.
    METROLOGIA, 2014, 51