Evaluation of the Roche Elecsys Toxo IgG and IgM electrochemiluminescence immunoassay for the detection of gestational Toxoplasma infection

被引:26
|
作者
Prusa, Andrea-Romana [1 ]
Hayde, Michael [1 ]
Unterasinger, Lukas [1 ]
Pollak, Arnold [1 ]
Herkner, Kurt R. [1 ,2 ]
Kasper, David C. [1 ,2 ]
机构
[1] Med Univ Vienna, Dept Paediat & Adolescent Med, A-1090 Vienna, Austria
[2] Med Univ Vienna, Res Core Unit Paediat Biochem & Analyt, A-1090 Vienna, Austria
关键词
Toxoplasma gondu Congenital toxoplasmosis; Gestational infection; Serologic screening; POLYMERASE-CHAIN-REACTION; IMMUNOSORBENT AGGLUTINATION ASSAY; FELDMAN DYE TEST; CONGENITAL TOXOPLASMOSIS; IMMUNOGLOBULIN-G; PREGNANT-WOMEN; PRENATAL TREATMENT; GONDII INFECTION; AMNIOTIC-FLUID; DIAGNOSIS;
D O I
10.1016/j.diagmicrobio.2010.07.011
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Unidentified gestational infection with Toxoplasma gondu may lead to fetal infection with severe complications later in childhood Because diagnosis of maternal infection solely depends on serology, routine tests with high sensitivity and specificity are required In this study, the new Roche Elecsys Toxo IgG and IgM immunoassay was compared with Sabin-Feldman dye test and immunosorbent agglutination assay-IgM as reference test Serum samples were analyzed from 927 pregnant women, including 100 negative, 706 chronic, and 121 acute infections The combination of both Elecsys IgG and IgM assays demonstrated high sensitivity and specificity of 97 1% and 100 0%, respectively, and a positive and negative predictive value of 100 0% and 81 3%, respectively The Elecsys assay is a useful tool as a first-line screening method to detect gestational infections However, if gestational infection is assumed, confirmatory testing by a reference laboratory might be necessary to discriminate between pre- and postconceptional infection to start antiparasitic treatment to avoid mother-tofetus transmission and severe sequelae (C) 2010 Elsevier Inc All rights reserved
引用
收藏
页码:352 / 357
页数:6
相关论文
共 50 条
  • [1] MULTICENTER EVALUATION OF THE ELECSYS TOXO IgG AND IgM TESTS FOR THE DIAGNOSIS OF INFECTION WITH TOXOPLASMA GONDII
    Meylan, Pascal
    Paris, Luc
    Liesenfeld, Oliver
    [J]. EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2015, 5 (02): : 150 - 158
  • [2] Performance of Elecsys® Toxo IgG and IgM Immunoassays
    van Helden, Josef
    [J]. CLINICAL LABORATORY, 2009, 55 (7-8) : 267 - 273
  • [3] Evaluation of fully automated assays for the detection of Rubella IgM and IgG antibodies by the Elecsys® immunoassay system
    van Helden, Josef
    Grangeot-Keros, Liliane
    Vauloup-Fellous, Christelle
    Vleminckx, Renaud
    Masset, Frederic
    Revello, Maria-Grazia
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2014, 199 : 108 - 115
  • [4] Elecsys® immunoassay systems using electrochemiluminescence detection
    Erler, K
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 1998, 110 : 5 - 10
  • [5] Comparative evaluation of the ARCHITECT Toxo IgG, IgM, and IgG Avidity assays for anti-Toxoplasma antibodies detection in pregnant women sera
    Gay-Andrieu, Francoise
    Fricker-Hidalgo, Helene
    Sickinger, Eva
    Espern, Anne
    Brenier-Pinchart, Marie-Pierre
    Braun, Hans-Bertram
    Pelloux, Herve
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 65 (03) : 279 - 287
  • [6] Performance evaluation of the Roche Elecsys® CMV IgG and IgM on the modular analytics E170
    Meylan, P.
    Chappuis, S.
    Laengin, T.
    Bertele, R.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2009, 46 : S48 - S48
  • [7] Bicentric evaluation of Access Toxo immunoglobulin M (IgM) and IgG assays and IMx Toxo IgM and IgG assays and comparison with platelia Toro IgM and IgG assays
    Decoster, A
    Lecolier, B
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (07) : 1606 - 1609
  • [8] Detection of immunoglobulin G (IgG) and IgM antibodies to Toxoplasma gondii: Evaluation of four commercial immunoassay systems
    Hofgartner, WT
    Swanzy, SR
    Bacina, RM
    Condon, J
    Gupta, M
    Matlock, PE
    Bergeron, DL
    Plorde, JJ
    Fritsche, TR
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (12) : 3313 - 3315
  • [9] Evaluation of plasma ACTH stability using the Roche Elecsys immunoassay
    Nandakumar, Vijayalakshmi
    Theobald, J. Paul
    Algeciras-Schimnich, Alicia
    [J]. CLINICAL BIOCHEMISTRY, 2020, 81 : 59 - 62
  • [10] System evaluation of ElectroChemiLuminescence immunoassay analyzer Elecsys(R) 1010
    Finke, W
    Furst, O
    Jansen, P
    Meyer, HD
    [J]. CLINICAL CHEMISTRY, 1996, 42 (06) : 193 - 193