Evaluation of fully automated assays for the detection of Rubella IgM and IgG antibodies by the Elecsys® immunoassay system

被引:5
|
作者
van Helden, Josef [1 ]
Grangeot-Keros, Liliane [2 ]
Vauloup-Fellous, Christelle [2 ]
Vleminckx, Renaud [3 ]
Masset, Frederic [3 ]
Revello, Maria-Grazia [4 ]
机构
[1] Med Versorgungszentrum Dr Stein & Kollegen, Lab Med Mikrobiol Infektionsepidemiol Virol Trans, D-41061 Monchengladbach, Germany
[2] Hop Antoine Beclere, Serv Microbiol Immunol Biol, Clamart, France
[3] LABM BIOPATH Cite Europe Quest, Coquelles, France
[4] Fdn IRCCS, Policlin San Matteo, Pavia, Italy
关键词
Rubella screening; Elecsys; Sensitivity; Specificity; PREGNANCY; AVIDITY; PREVENTION; INFECTION; PARTICLES;
D O I
10.1016/j.jviromet.2014.01.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Screening for acute rubella infection in pregnancy is an important element of antenatal care. This study compared the sensitivity, specificity and reproducibility of two new, fully automated Elecsys (R) Rubella IgM and IgG immunoassays designed for the Elecsys 2010, Modular Analytics E170, COBAS e-411 and COBAS e-601 and e602 analytical platforms, with current assays using serum from patients with primary rubella infections, vaccinated patients, patients with potentially cross-reacting infections and on routine samples in clinical laboratories in France, Germany and Italy. Both assays showed good within-run and within-laboratory precision. A sensitivity of 79.8-96.0% was demonstrated for Elecsys IgM in primary, early acute infection, consistent with existing assays. In samples obtained from routine antenatal screening, the Elecsys Rubella IgM assay revealed high specificity (98.7-99.0%). A significantly (p < 0.0001) lower reactivity was demonstrated in samples from previously infected patients where acute rubella infection was excluded, and the incidence of false positives in patients with potentially cross-reacting infections was lower with Elecsys Rubella IgM compared with other. The Elecsys Rubella IgG assay exhibited a relative-sensitivity of 99.9-100.0% and specificity of 97.4-100.0% in samples from routine antenatal screening. The Elecsys Rubella IgM and IgG assays allow convenient, rapid and reliable determination of anti-rubella antibodies. Sensitivity, specificity and reproducibility were comparable with existing assay systems. Assay results were available in approximately half the time required for currently employed methods and the assays are compatible with widely used analytical platforms. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:108 / 115
页数:8
相关论文
共 50 条
  • [1] Performance Evaluation of a Fully Automated Immunoassay for the Detection of Human Growth Hormone on the Elecsys® Immunoassay System
    van Helden, Josef
    Hermsen, Derek
    von Ahsen, Nicholas
    Bidlingmaier, Martin
    [J]. CLINICAL LABORATORY, 2014, 60 (10) : 1641 - 1651
  • [2] Evaluation of an automated chemiluminescent immunoassay for the detection of anti-rubella virus IgM antibodies
    Pustowoit, B.
    Liebert, U. G.
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S318 - S318
  • [3] Clinical evaluation of new automated cytomegalovirus IgM and IgG assays for the Elecsys® analyser platform
    M. G. Revello
    C. Vauloup-Fellous
    L. Grangeot-Keros
    J. van Helden
    Y. Dickstein
    I. Lipkin
    A. Mühlbacher
    T. Lazzarotto
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2012, 31 : 3331 - 3339
  • [4] Evaluation of four fully-automated immunoassays for the detection of cytomegalovirus IGM and IGG antibodies
    Ly, T. D.
    Dautigny, M.
    Gonzalo, S.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2009, 46 : S49 - S49
  • [5] Evaluation of the Roche Elecsys Toxo IgG and IgM electrochemiluminescence immunoassay for the detection of gestational Toxoplasma infection
    Prusa, Andrea-Romana
    Hayde, Michael
    Unterasinger, Lukas
    Pollak, Arnold
    Herkner, Kurt R.
    Kasper, David C.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2010, 68 (04) : 352 - 357
  • [6] Evaluation of Rubella IgG and IgM assays on the new Vidia® instrument
    Medici, M. C.
    Albonetti, V.
    Martinelli, M.
    Chezzi, C.
    Dettori, G.
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S640 - S641
  • [7] Clinical Evaluation of Fully Automated Elecsys® Syphilis Assay for the Detection of Antibodies of Treponema pallidum
    Li, Dongdong
    An, Jingna
    Wang, Tingting
    Tao, Chuanmin
    Wang, Lanlan
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (06) : 1164 - 1168
  • [8] Evaluation of antinuclear antibodies (ANA) detection with a fully automated enzyme immunoassay
    Haliassos, A
    Papasteriadi, C
    Tsirogianni, A
    Farmakis, G
    Siorfane, A
    [J]. CLINICAL CHEMISTRY, 2004, 50 (06) : A52 - A52
  • [9] AN EVALUATION OF ELISA KITS FOR RUBELLA IGG-ANTIBODIES AND IGM-ANTIBODIES
    PARISHAMELIN, A
    FUSTECIBARBOURE, S
    [J]. JOURNAL OF VIROLOGICAL METHODS, 1985, 10 (04) : 355 - 361
  • [10] DETECTION OF RUBELLA VIRUS-SPECIFIC IMMUNOGLOBULIN-G (IGG), IGM, AND IGA ANTIBODIES BY IMMUNOBLOT ASSAYS
    ZHANG, T
    MAURACHER, CA
    MITCHELL, LA
    TINGLE, AJ
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (04) : 824 - 830