Diagnostic yield of endoscopic ultrasound-guided liver biopsy in comparison to percutaneous liver biopsy: a systematic review and meta-analysis

被引:16
|
作者
Facciorusso, Antonio [1 ,2 ]
Crino, Stefano Francesco [2 ]
Ramai, Daryl [3 ]
Fabbri, Carlo [4 ]
Mangiavillano, Benedetto [5 ]
Lisotti, Andrea [6 ]
Muscatiello, Nicola [1 ]
Cotsoglou, Christian [7 ]
Fusaroli, Pietro [6 ]
机构
[1] Osped Riuniti Di Foggia, Sect Gastroenterol, Dept Med & Surg Sci, Foggia, Italy
[2] Univ Hosp Verona, Pancreas Inst, Gastroenterol & Digest Endoscopy Unit, Dept Med, Verona, Italy
[3] Brooklyn Hosp, Gastroenterol & Hepatol, Med Ctr, Brooklyn, NY USA
[4] Forli Cesena Hosp, Gastroenterol & Digest Endoscopy Unit, Ausl Romagna, Forli Cesena, Italy
[5] Humanitas Mater Domini, Gastrointestinal Endoscopy Unit, Castellanza, Italy
[6] Univ Bologna, Hosp Imola, Gastroenterol Unit, Bologna, Italy
[7] ASST Brianza, Vimercate Hosp, Gen Surg Unit, Vimercate, Italy
关键词
EUS; FNB; FNA; adequacy; FINE-NEEDLE-ASPIRATION; PANCREATIC LESIONS; ANTIVIRAL THERAPY; HEPATITIS-C; FORK-TIP; STIFFNESS; SAFETY;
D O I
10.1080/17474124.2022.2020645
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background It is still unclear whether endoscopic ultrasound liver biopsy (EUS-LB) determines superior results in comparison to percutaneous liver biopsy (PC-LB). Aim of this meta-analysis was to compare the diagnostic outcomes of these two techniques. Research Design and Methods Literature search was conducted through June 2021 and identified 7 studies. The primary outcome was total length of specimen. Results were expressed as odds ratio (OR) or mean difference along with 95% confidence interval (CI). Results Pooled total length of specimen was 29.9 mm (95% CI 24.1-35.7) in the EUS-LB group and 29.7 mm (95% CI 27.1-32.2) in the PC-LB group, with no difference between the two approaches (mean difference -0.35 mm, 95% CI -5.31 to 4.61; p = 0.89), although sensitivity analysis restricted to higher quality studies found a superior performance of PC-LB over EUS-LB. Pooled number of complete portal tracts was 12.9 (7.7-18) in the EUS-LB and 14.4 (10.7-18) in the PC-LB group, with no difference in direct comparison (mean difference -1.58, -5.98 to 2.81; p = 0.48). No difference between the two groups was observed in terms of severe adverse event rate (OR 1.11, 0.11-11.03; p = 0.93). Conclusion EUS-LB and PC-LB are comparable in terms of diagnostic performance and safety profile.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [41] Ultrasound-guided percutaneous biopsy for focal liver lesions: Adverse events and diagnostic yield in a single-centre analysis
    Poeschel, Theresa
    Blank, Valentin
    Schlosser, Tobias
    Lingscheidt, Thomas
    Boehlig, Albrecht
    Wiegand, Johannes
    Karlas, Thomas
    PLOS ONE, 2024, 19 (05):
  • [42] USE OF ENDOSCOPIC ULTRASOUND-GUIDED THROUGH-THE-NEEDLE MICROFORCEPS BIOPSY IMPROVES DIAGNOSTIC YIELD FOR PANCREATIC CYSTIC LESIONS: A SYSTEMATIC REVIEW AND META-ANALYSIS
    McCarty, Thomas R.
    Rustagi, Tarun
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB201 - AB202
  • [43] Diagnostic Value of Ultrasound-Guided Needle Biopsy in Undiagnosed Pleural Effusions: A Systematic Review and Meta-Analysis
    Lin, Z.
    Wang, J.
    Wu, D.
    Wang, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [44] Diagnostic value of ultrasound-guided needle biopsy in undiagnosed pleural effusions A systematic review and meta-analysis
    Lin, Zhidi
    Wu, Donghong
    Wang, Jinlin
    Wang, Chuqiao
    Huang, Mingkai
    MEDICINE, 2020, 99 (27) : E21076
  • [45] Efficacy and Safety of Endoscopic Ultrasound-Guided Liver Biopsies in Parenchymal Liver Diseases: A Systematic Review and Meta-Analysis
    Shah, Anup
    Martinez, Isabel C. Guerrido
    Valentin, Nelson
    Golfeyz, Shmuel
    Collins, Kelsey E.
    Hershman, Melissa
    Weisberg, Ilan
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2018, 113 : S565 - S566
  • [46] EFFICACY AND SAFETY OF ENDOSCOPIC ULTRASOUND-GUIDED LIVER BIOPSIES IN PARENCHYMAL LIVER DISEASES: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Shah, Anup
    Martinez, Isabel Guerrido
    Valentin, Nelson
    Hershman, Melissa
    Collins, Kelsey
    Golfeyz, Shmuel
    Weisberg, Ilan
    GASTROINTESTINAL ENDOSCOPY, 2019, 89 (06) : AB326 - AB327
  • [47] Efficacy and safety of endoscopic ultrasound-guided liver biopsies in parenchymal liver diseases: A systematic review and meta-analysis
    Shah, Anup
    Martinez, Isabel Guerrido
    Valentin, Nelson
    Hershman, Melissa
    Collins, Kelsey
    Golfeyz, Shmuel
    Weisberg, Ilan
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : E316 - E316
  • [48] ENDOSCOPIC ULTRASOUND-GUIDED ABLATION TECHNIQUES FOR LIVER TUMORS. A SYSTEMATIC REVIEW AND META-ANALYSIS
    Gonzalez, Juan
    Nunes, Felipe
    Landim, Davi
    Aguirre, Diego Cadena
    Bernardo, Wanderley
    De Moura, Diogo
    De Moura, Eduardo
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (06) : AB813 - AB813
  • [49] Ultrasound-guided percutaneous liver biopsy: A review of what operators need to know
    Alturkistani, Husain
    Alsergani, Abdullah H.
    Alzeer, Meshari
    Alturkistani, Anas
    Zaini, Renad
    Bauones, Salem
    MEDICINE, 2024, 103 (30)
  • [50] DIAGNOSTIC YIELD OF TWO ENDOSCOPIC ULTRASOUND-GUIDED LIVER BIOPSY TECHNIQUES ("WET SALINE" AND "WET HEPARIN") FOR PARENCHYMAL LIVER DISEASE
    Saraireh, Hamzeh
    Abdelfattah, Thaer
    Puri, Puneet
    Lippman, Robert
    Mutha, Pritesh R.
    Fuchs, Michael
    Shah, Tilak U.
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB333 - AB333