Diagnostic yield of endoscopic ultrasound-guided liver biopsy in comparison to percutaneous liver biopsy: a systematic review and meta-analysis

被引:16
|
作者
Facciorusso, Antonio [1 ,2 ]
Crino, Stefano Francesco [2 ]
Ramai, Daryl [3 ]
Fabbri, Carlo [4 ]
Mangiavillano, Benedetto [5 ]
Lisotti, Andrea [6 ]
Muscatiello, Nicola [1 ]
Cotsoglou, Christian [7 ]
Fusaroli, Pietro [6 ]
机构
[1] Osped Riuniti Di Foggia, Sect Gastroenterol, Dept Med & Surg Sci, Foggia, Italy
[2] Univ Hosp Verona, Pancreas Inst, Gastroenterol & Digest Endoscopy Unit, Dept Med, Verona, Italy
[3] Brooklyn Hosp, Gastroenterol & Hepatol, Med Ctr, Brooklyn, NY USA
[4] Forli Cesena Hosp, Gastroenterol & Digest Endoscopy Unit, Ausl Romagna, Forli Cesena, Italy
[5] Humanitas Mater Domini, Gastrointestinal Endoscopy Unit, Castellanza, Italy
[6] Univ Bologna, Hosp Imola, Gastroenterol Unit, Bologna, Italy
[7] ASST Brianza, Vimercate Hosp, Gen Surg Unit, Vimercate, Italy
关键词
EUS; FNB; FNA; adequacy; FINE-NEEDLE-ASPIRATION; PANCREATIC LESIONS; ANTIVIRAL THERAPY; HEPATITIS-C; FORK-TIP; STIFFNESS; SAFETY;
D O I
10.1080/17474124.2022.2020645
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background It is still unclear whether endoscopic ultrasound liver biopsy (EUS-LB) determines superior results in comparison to percutaneous liver biopsy (PC-LB). Aim of this meta-analysis was to compare the diagnostic outcomes of these two techniques. Research Design and Methods Literature search was conducted through June 2021 and identified 7 studies. The primary outcome was total length of specimen. Results were expressed as odds ratio (OR) or mean difference along with 95% confidence interval (CI). Results Pooled total length of specimen was 29.9 mm (95% CI 24.1-35.7) in the EUS-LB group and 29.7 mm (95% CI 27.1-32.2) in the PC-LB group, with no difference between the two approaches (mean difference -0.35 mm, 95% CI -5.31 to 4.61; p = 0.89), although sensitivity analysis restricted to higher quality studies found a superior performance of PC-LB over EUS-LB. Pooled number of complete portal tracts was 12.9 (7.7-18) in the EUS-LB and 14.4 (10.7-18) in the PC-LB group, with no difference in direct comparison (mean difference -1.58, -5.98 to 2.81; p = 0.48). No difference between the two groups was observed in terms of severe adverse event rate (OR 1.11, 0.11-11.03; p = 0.93). Conclusion EUS-LB and PC-LB are comparable in terms of diagnostic performance and safety profile.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [21] Update on endoscopic ultrasound-guided liver biopsy
    Shiva Rangwani
    Devarshi R Ardeshna
    Khalid Mumtaz
    Sean G Kelly
    Samuel Y Han
    Somashekar G Krishna
    World Journal of Gastroenterology, 2022, (28) : 3586 - 3594
  • [22] Update on endoscopic ultrasound-guided liver biopsy
    Rangwani, Shiva
    Ardeshna, Devarshi R.
    Mumtaz, Khalid
    Kelly, Sean G.
    Han, Samuel Y.
    Krishna, Somashekar G.
    WORLD JOURNAL OF GASTROENTEROLOGY, 2022, 28 (28) : 3586 - 3594
  • [23] Endoscopic Ultrasound-Guided Liver Biopsy Versus Percutaneous and Trans-Jugular Liver Biopsy for Evaluation of Liver Parenchyma
    Shahshahan, Mohammad
    Gertz, Henning
    Fakhreddine, Ali Y.
    Datta, Anuj
    Eysselein, Viktor E.
    Reicher, Sofiya
    French, Samuel W.
    Hou, Linda A.
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (05) : AB490 - AB490
  • [24] COMPARISON OF THE PERFORMANCE OF 2 CORE BIOPSY NEEDLES FOR ENDOSCOPIC ULTRASOUND-GUIDED LIVER BIOPSY
    Ellis, Daniel J.
    Siddiqi, Faisal
    Therapondos, George
    Shah, Janak N.
    Romero, Ricardo V.
    Evans, John
    El Chafic, Abdul H.
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB320 - AB320
  • [25] META-ANALYSIS OF EUS GUIDED LIVER BIOPSY IN COMPARISON WITH PERCUTANEOUS AND TRANSJUGULAR LIVER BIOPSY FOR THE DIAGNOSIS OF PARENCHYMAL LIVER DISEASE
    Mony, Shruti
    Shah, Ishani
    Vyas, Neil
    Sofi, Aijaz
    Das, Ananya
    GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : AB328 - AB329
  • [26] Assessing the diagnostic accuracy of ultrasound-guided percutaneous cutting-needle pleural biopsy - A systematic review and meta-analysis
    Bardon, Michael Pace
    Ahmad, Nawaid
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [27] Safety and adequacy of endoscopic ultrasound-guided random liver biopsy in comparison with transjugular and percutaneous approaches
    Bhogal, Neil
    Lamb, Bernadette
    Arbeiter, Benjamin
    Malik, Sarah
    Sayles, Harlan
    Lazenby, Audrey J.
    Chandan, Saurabh
    Dhaliwal, Amaninder
    Singh, Shailender
    Bhat, Ishfaq
    ENDOSCOPY INTERNATIONAL OPEN, 2020, 08 (12) : E1850 - E1854
  • [28] Endoscopic ultrasound-guided through-the-needle microforceps biopsy improves diagnostic yield for pancreatic cystic lesions: a systematic review and meta-analysis
    McCarty, Thomas
    Rustagi, Tarun
    ENDOSCOPY INTERNATIONAL OPEN, 2020, 08 (10) : E1280 - E1290
  • [29] Ultrasound-Guided Percutaneous Liver Biopsy: A Review on Obtaining Adequate Specimens
    de Lange, Danny
    van den Dobbelsteen, John J.
    Moelker, Adriaan
    van de Berg, Nick J.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2020, 14 (03): : OBITUARIE
  • [30] Blind and ultrasound-guided percutaneous liver biopsy in children
    Valerio Nobili
    Donatella Comparcola
    Maria Rita Sartorelli
    Gianluigi Natali
    Lidia Monti
    Piergiorgio Falappa
    Matilde Marcellini
    Pediatric Radiology, 2003, 33 : 772 - 775