HIP zirconia fixed partial dentures - Clinical results after 3 years of clinical service

被引:0
|
作者
Edelhoff, Daniel [1 ]
Beuer, Florian [1 ]
Weber, Volker [2 ]
Johnen, Christine [3 ]
机构
[1] Univ Munich, Dept Prosthodont, D-80336 Munich, Germany
[2] Dent Lab Impladent, Aachen, Germany
[3] Univ Aachen, Med Ctr, Dept Orthodont, D-5100 Aachen, Germany
来源
QUINTESSENCE INTERNATIONAL | 2008年 / 39卷 / 06期
关键词
CAD/CAM; fixed partial dentures; veneering ceramic; zirconia ceramic;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate prospectively the clinical performance of 3- to 6-unit zirconia fixed partial dentures (FPDs) after more than 3 years of clinical service. Method and Materials: Since August 2002, 22 conventional all-ceramic FPDs have been inserted in 18 patients. Nineteen of the FPDs were placed with a resin-reinforced glass-ionomer cement. The frameworks were manufactured by a universal CAD/CAM production system, milling the zirconia out of the densely sintered stage. The frameworks were designed as 3- unit (14), 4-unit (3), 5-unit (2), and 6-unit FPDs (3) for the anterior and posterior regions. A new synthetic sintering glass-ceramic was employed as the veneering material. In the follow-up examinations at baseline, 6, 12, 24, and 36 months, 21 FPDs were inspected predominantly for framework fractures and chipping of the veneering material. Besides these parameters, periodontal status, sensitivity of the abutment teeth, esthetic outcome, as well as the incidence of secondary caries, were evaluated. Results: After a mean clinical observation of over 39 months, no framework fracture occurred. However, chipping of the veneering material was reported in 2 cases. Conclusion: All-ceramic FPDs based on zirconia frameworks exhibited satisfactory clinical performance.
引用
收藏
页码:459 / 471
页数:13
相关论文
共 50 条
  • [41] Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia: Clinical Report after Two Years in Service
    Rojas-Vizcaya, Fernando
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (07): : 570 - 576
  • [42] Clinical application of all-ceramic fixed partial dentures and crowns
    Toksavul, S
    Ulusoy, M
    Toman, M
    QUINTESSENCE INTERNATIONAL, 2004, 35 (03): : 185 - 188
  • [43] Resin-bonded fixed partial dentures .2. Clinical findings related to prosthodontic characteristics after approximately 10 years
    Wood, M
    Thompson, VP
    Romberg, E
    Morrison, G
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (04): : 368 - 373
  • [44] Retrospective clinical evaluation of posterior monolithic zirconia restorations after 1 to 3.5 years of clinical service
    Gunge, Hiroto
    Ogino, Yoichiro
    Kihara, Masafumi
    Tsukiyama, Yoshihiro
    Koyano, Kiyoshi
    JOURNAL OF ORAL SCIENCE, 2018, 60 (01) : 154 - 158
  • [45] Maxillary zirconia implant fixed partial dentures opposing an acrylic resin implant fixed complete denture: A two-year clinical report
    Chang, Paul P.
    Henegbarth, Ernst A.
    Lang, Lisa A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : 321 - 330
  • [46] Clinical performance and periodontal outcome of temporary crowns and fixed partial dentures: A randomized clinical trial
    Luthardt, RG
    Stossel, M
    Hinz, M
    Vollandt, R
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (01): : 32 - 39
  • [47] CLINICAL-EVALUATION OF PATIENTS 8 TO 9 YEARS AFTER PLACEMENT OF REMOVABLE PARTIAL DENTURES
    CHANDLER, JA
    BRUDVIK, JS
    JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (06): : 736 - 743
  • [48] CLINICAL-STUDY OF PATIENTS 1 TO 2 YEARS AFTER PLACEMENT OF REMOVABLE PARTIAL DENTURES
    SCHWALM, CA
    SMITH, DE
    ERICKSON, JD
    JOURNAL OF PROSTHETIC DENTISTRY, 1977, 38 (04): : 380 - 391
  • [49] Clinical and scanning electron microscopic evaluation of fiber-reinforced inlay fixed partial dentures:: Preliminary results after one year
    Göhring, TN
    Mörmann, WH
    Lutz, F
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (06): : 662 - 668
  • [50] Effect of framework design on the surface strain of zirconia fixed partial dentures
    Nemoto, Reina
    Nozaki, Kosuke
    Fukui, Yuji
    Yamashita, Kimihiro
    Miura, Hiroyuki
    DENTAL MATERIALS JOURNAL, 2013, 32 (02) : 289 - 295