HIP zirconia fixed partial dentures - Clinical results after 3 years of clinical service

被引:0
|
作者
Edelhoff, Daniel [1 ]
Beuer, Florian [1 ]
Weber, Volker [2 ]
Johnen, Christine [3 ]
机构
[1] Univ Munich, Dept Prosthodont, D-80336 Munich, Germany
[2] Dent Lab Impladent, Aachen, Germany
[3] Univ Aachen, Med Ctr, Dept Orthodont, D-5100 Aachen, Germany
来源
QUINTESSENCE INTERNATIONAL | 2008年 / 39卷 / 06期
关键词
CAD/CAM; fixed partial dentures; veneering ceramic; zirconia ceramic;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate prospectively the clinical performance of 3- to 6-unit zirconia fixed partial dentures (FPDs) after more than 3 years of clinical service. Method and Materials: Since August 2002, 22 conventional all-ceramic FPDs have been inserted in 18 patients. Nineteen of the FPDs were placed with a resin-reinforced glass-ionomer cement. The frameworks were manufactured by a universal CAD/CAM production system, milling the zirconia out of the densely sintered stage. The frameworks were designed as 3- unit (14), 4-unit (3), 5-unit (2), and 6-unit FPDs (3) for the anterior and posterior regions. A new synthetic sintering glass-ceramic was employed as the veneering material. In the follow-up examinations at baseline, 6, 12, 24, and 36 months, 21 FPDs were inspected predominantly for framework fractures and chipping of the veneering material. Besides these parameters, periodontal status, sensitivity of the abutment teeth, esthetic outcome, as well as the incidence of secondary caries, were evaluated. Results: After a mean clinical observation of over 39 months, no framework fracture occurred. However, chipping of the veneering material was reported in 2 cases. Conclusion: All-ceramic FPDs based on zirconia frameworks exhibited satisfactory clinical performance.
引用
收藏
页码:459 / 471
页数:13
相关论文
共 50 条
  • [31] Two years clinical evaluation of fiber-reinforced inlay fixed partial dentures.
    Monaco, C
    Arculiuciano, A
    Mulferrari, S
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B236 - B236
  • [32] The Clinical Success of Inlay-Retained Fixed Partial Dentures
    Keban, Seda
    Turker, Sebnem Begum
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2016, 6 (04): : 178 - 186
  • [33] Assessment of failure rate of fixed partial dentures: A clinical study
    Dewan, Harisha
    Haroon, T. Mohamed
    Mogla, Sahil
    Gupta, Anusar
    Loganathan, Jeevanandam
    Ahammed, A. Niaz
    Kommuri, Sirisha
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 262 - 263
  • [34] Proximal contour modifications for fixed partial dentures: A clinical report
    Kaiser, DA
    Jones, JD
    JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (04): : 344 - 345
  • [35] Clinical evaluation of fixed partial dentures made in Sweden and China
    Ekblom, Karin
    Smedberg, Jan-Ivan
    Moberg, Lars-Erik
    SWEDISH DENTAL JOURNAL, 2011, 35 (03) : 111 - 122
  • [36] Clinical performance of resin-bonded fixed partial dentures
    Boening, KW
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (01): : 39 - 44
  • [37] A LONGITUDINAL CLINICAL-STUDY OF BONDED FIXED PARTIAL DENTURES - THE 1ST 5 YEARS
    CRISPIN, BJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1991, 66 (03): : 336 - 342
  • [38] Fit of monolithic multilayer zirconia fixed partial dentures fabricated by conventional versus digital impression: a clinical and laboratory investigations
    Noha Morsy
    Mohammed El Kateb
    Amir Azer
    Said Fathalla
    Clinical Oral Investigations, 2021, 25 : 5363 - 5373
  • [39] Fit of monolithic multilayer zirconia fixed partial dentures fabricated by conventional versus digital impression: a clinical and laboratory investigations
    Morsy, Noha
    El Kateb, Mohammed
    Azer, Amir
    Fathalla, Said
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (09) : 5363 - 5373
  • [40] Fractographic analyses of zirconia-based fixed partial dentures
    Taskonak, Burak
    Yan, Jiahau
    Mecholsky, John J., Jr.
    Sertgoez, Atilla
    Kocak, Ayse
    DENTAL MATERIALS, 2008, 24 (08) : 1077 - 1082