HIP zirconia fixed partial dentures - Clinical results after 3 years of clinical service

被引:0
|
作者
Edelhoff, Daniel [1 ]
Beuer, Florian [1 ]
Weber, Volker [2 ]
Johnen, Christine [3 ]
机构
[1] Univ Munich, Dept Prosthodont, D-80336 Munich, Germany
[2] Dent Lab Impladent, Aachen, Germany
[3] Univ Aachen, Med Ctr, Dept Orthodont, D-5100 Aachen, Germany
来源
QUINTESSENCE INTERNATIONAL | 2008年 / 39卷 / 06期
关键词
CAD/CAM; fixed partial dentures; veneering ceramic; zirconia ceramic;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate prospectively the clinical performance of 3- to 6-unit zirconia fixed partial dentures (FPDs) after more than 3 years of clinical service. Method and Materials: Since August 2002, 22 conventional all-ceramic FPDs have been inserted in 18 patients. Nineteen of the FPDs were placed with a resin-reinforced glass-ionomer cement. The frameworks were manufactured by a universal CAD/CAM production system, milling the zirconia out of the densely sintered stage. The frameworks were designed as 3- unit (14), 4-unit (3), 5-unit (2), and 6-unit FPDs (3) for the anterior and posterior regions. A new synthetic sintering glass-ceramic was employed as the veneering material. In the follow-up examinations at baseline, 6, 12, 24, and 36 months, 21 FPDs were inspected predominantly for framework fractures and chipping of the veneering material. Besides these parameters, periodontal status, sensitivity of the abutment teeth, esthetic outcome, as well as the incidence of secondary caries, were evaluated. Results: After a mean clinical observation of over 39 months, no framework fracture occurred. However, chipping of the veneering material was reported in 2 cases. Conclusion: All-ceramic FPDs based on zirconia frameworks exhibited satisfactory clinical performance.
引用
收藏
页码:459 / 471
页数:13
相关论文
共 50 条
  • [1] Zirconia Posterior Fixed Partial Dentures: 5-Year Clinical Results of a Prospective Clinical Trial
    Schmitt, Johannes
    Goellner, Matthias
    Lohbauer, Ulrich
    Wichmann, Manfred
    Reich, Sven
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (06) : 585 - 589
  • [2] Zirconia-based fixed partial dentures: A clinical review
    Bachhav, Vinay Chila
    Aras, Meena Ajay
    QUINTESSENCE INTERNATIONAL, 2011, 42 (02): : 173 - 182
  • [3] Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
    Sailer, Irena
    Feher, Aurel
    Filser, Frank
    Gauckler, Ludwig J.
    Luethy, Heinz
    Hammerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2007, 20 (04) : 383 - 388
  • [4] A CLINICAL-STUDY OF FAILURE OF FIXED PARTIAL DENTURES AFTER 15 YEARS
    VALDERHAUG, J
    NORHEIM, PW
    AMBJORNSEN, E
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 702 - 702
  • [5] Prospective Evaluation of Zirconia Posterior Fixed Partial Dentures: Four-Year Clinical Results
    Roediger, Matthias
    Gersdorff, Nikolaus
    Huels, Alfons
    Rinke, Sven
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (02) : 141 - 148
  • [6] Prospective Evaluation of Zirconia Posterior Fixed Partial Dentures: 7-Year Clinical Results
    Rinke, Sven
    Gersdorff, Nikolaus
    Lange, Katharina
    Roediger, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (02) : 164 - 171
  • [7] 3-year clinical results of zirconia posterior fixed partial dentures made Direct Ceramic Machining (DCM).
    Sailer, I.
    Luethy, H.
    Feher, A.
    Schumacher, M.
    Schaerer, P.
    Hammerle, C. H. F.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B21 - B21
  • [8] A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years
    Fernanda Sola-Ruiz, Maria
    Agustin-Panadero, Ruben
    Fons-Font, Antonio
    Labaig-Rueda, Carlos
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (06): : 578 - 584
  • [9] Outcome of zirconia partial fixed dental prostheses made by predoctoral dental students: A clinical retrospective study after 3 to 7 years of clinical service
    Pihlaja, Juha
    Napankangas, Ritva
    Raustia, Aune
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (01): : 40 - 46
  • [10] Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
    Wettstein, Fabian
    Sailer, Irena
    Roos, Malgorzata
    Haemmerle, Christoph H. F.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2008, 116 (03) : 272 - 279