Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in cats

被引:2
|
作者
Ricci, Claudia Lizandra [1 ]
Giuffrida, Rogerio [2 ]
Kanashiro, Glaucia Prada [3 ]
Rufino Belezzi, Hilidia Stephania [4 ]
Bacarin, Carolina de Carvalho [4 ]
Tenorio, Michele Paulo [4 ]
Duran Foglia, Bruna Toledo [4 ]
Andrade, Silvia Franco [5 ,6 ]
机构
[1] Univ Oeste Paulista UNOESTE, Curso Med Vet, Ciencia Anim, Presidente Prudente, SP, Brazil
[2] Univ Oeste Paulista, Curso Med Vet, Dept Bioestat, Presidente Prudente, SP, Brazil
[3] Univ Oeste Paulista, Curso Med Vet, Dept Anestesiol, Presidente Prudente, SP, Brazil
[4] Univ Oeste Paulista, Curso Curso Med Vet, Presidente Prudente, SP, Brazil
[5] Univ Oeste Paulista, Curso Med Vet, Dept Clin Med Pequenos Anim, Presidente Prudente, SP, Brazil
[6] Univ Oeste Paulista, Ciencia Anim, Presidente Prudente, SP, Brazil
来源
SEMINA-CIENCIAS AGRARIAS | 2017年 / 38卷 / 06期
关键词
Applanation tonometer; Ocular manometry; Intraocular pressure; Cats; TONO-PEN XL(R); GLAUCOMA; DOGS;
D O I
10.5433/1679-0359.2017v38n6p3647
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The objective of this study was to evaluate the use of the Kowa HA-2 applanation tonometer in measuring intraocular pressure (IOP) in cats. Ten healthy eyes were used in an ex vivo study in which the calibration curve for manometry vs. tonometry was determined by artificially raising the IOP in 5 mmHg increments up to 60 mmHg (10-60 mmHg). Both eyes of 10 anesthetized cats were studied in vivo to compare manometry vs. tonometry. In the ambulatory study, 78 healthy eyes, 7 eyes with glaucoma and 20 eyes with uveitis were evaluated by tonometry, which was performed with topical anesthesia and 1% fluorescein eye drops for the formation of fluorescein semicircles. The correlation coefficient (r(2)) between the manometer and the Kowa HA-2 tonometer was 0.993 and the linear regression equation was y = 0.0915x + 0.0878 in the ex-vivo study. In the in vivo study, the IOP values (mean +/- SD, in mmHg) in manometry were 15.6 +/- 1.1(14.0-17.5) and in tonometry were 15.5 +/- 1.2(13.5-17.2), with no significant difference (P > 0.05) between manometry and tonometry. In ambulatory study, using the Kowa HA-2 tonometer, the IOP values (mean +/- SD, in mmHg) were 15.0 +/- 1.5 (11.8-18.3) for the healthy eyes, 38.4 +/- 8.1(29.6-53.7) for glaucomatous eyes and 10.4 +/- 2.0(5.3-12.2) for eyes with uveitis. There was a strong correlation and accuracy between the IOP values with the manometry and the Kowa HA-2 tonometer. In the ambulatory study the IOP values obtained with the tonometer were compatible for animals with healthy eyes and with clinical signs of glaucoma and uveitis. We conclude that the Kowa HA-2 tonometer can be used in the measurement of IOP in cats, since it is a practical and accurate method in this species.
引用
收藏
页码:3647 / 3655
页数:9
相关论文
共 50 条
  • [21] Study of Accuracy of Intraocular Pressure measured by non-contact (air puff) Tonometer confirmed by Goldmann Applanation Tonometer
    Dibaji, Mohammad
    Shaikh, Rehan Moinuddin
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (03): : 972 - 974
  • [22] Real-time intraocular pressure measurement during phacoemulsification in dogs ex vivo
    Kang, Seonmi
    Park, Sangwan
    Noh, Hyunwoo
    Kwak, Jiyoon
    Seo, Kangmoon
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2015, 77 (06): : 685 - 692
  • [23] Effect of corneal astigmatism on intraocular pressure measurement using ocular response analyzer and Goldmann applanation tonometer
    Hagishima, Mana
    Kamiya, Kazutaka
    Fujimura, Fusako
    Morita, Tetsuya
    Shoji, Nobuyuki
    Shimizu, Kimiya
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (02) : 257 - 262
  • [24] Red-free light for measurement of intraocular pressure using Goldmann applanation tonometer without fluorescein
    Ghoneim, Ehab M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (01) : 84 - 87
  • [25] Measurement of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet®) and the applanation tonometer (Tono-Pen Vet®)
    Kulualp, Kadri
    Yurdakul, Ibrahim
    Erol, Hanifi
    Atalan, Gultekin
    Kilic, Servet
    MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2018, 74 (09): : 568 - 573
  • [26] THE COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT BY GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR PUFF TONOMETER: A CROSS-SECTIONAL RESEARCH
    Arooj, Bushra
    Nadeem, Asmarah
    Ali, Sobia
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (12): : 16875 - 16879
  • [27] ASSESSMENT OF THE FACTORS INFLUENCING AND COMPARING THE INTRAOCULAR PRESSURE WITH THE HELP OF SCHIOTZ INDENTATION TONOMETER AND GOLDMANN'S APPLANATION TONOMETER: A CLINICAL STUDY
    Amarnath, Mridula V.
    Samuel, Christina
    Sundararajan, D.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2015, 4 (01): : 58 - 64
  • [28] Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    Lösch, A
    Scheuerle, A
    Rupp, V
    Auffarth, G
    Becker, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (04) : 313 - 316
  • [29] The effect of corneal pathology on intraocular pressure measurement using the OBF pneumotonometer, Tonopen and Goldmann applanation tonometer.
    Browning, AC
    Bhan, A
    Shah, S
    Dua, HS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S282 - S282
  • [30] Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    Annette Lösch
    Alexander Scheuerle
    Volker Rupp
    Gerd Auffarth
    Matthias Becker
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 313 - 316